OMC-140 Manual supplement SD-logging – Wind Alarm functionality
Page 8
3 Data log function
3.1 Introduction
In firmware version 1.00B22 the data log function is included. From this version and up all relevant data
can be logged on a Micro SD card and will be stored per day in .txt files.
The format is compatible with the Observator data loggers and can be read by OMC-Data-Online or
imported in for example Microsoft Excel.
3.2 Data log function settings
The data log function can be enabled using the USB menu, for USB menu connection details see OMC-
140 installation manual.
All log related functions are in the menu
5 SD Log Settings.
1. SD logging
On
or
Off
2. Storage interval
10 minute, 2 minute or 5 second interval
3. Set Date
Option to correct the date
Format: =yy/mm/dd (the ‘=’must be included!)
4. Set Time GMT
Option to correct the time:
Format: =hh:mm:ss (the ‘=’ must be included!)
* GPS message at noon (if available)
* Once SD logging is selected
On
GGA message is available; time will be daily synchronized with the
UTC time. Since date is not in the GGA message this will not be synchronized like the time!