Page 15: ...f hrungs ffnungen 4 f r Installationsrohre M20 oder M25 Der Rahmen 3 ist durch vier Nivel lierst tzen 5 auf Oberkante Bodenbelag ein stellbar Die Mindesteinbautiefe betr gt 95 mm der Nivellierbereich...

Page 16: ...Betonboden Klappdeckel ffnen und abnehmen Klappdeckel z B mit einem Schlitzschrau bendreher ffnen Klappdeckel wie gezeigt drehen und dann abnehmen Ger teeinsatz montieren Steckdoseneinsatz ggf durch...

Page 17: ...e ffnung 25 mm Ger teeinsatz mit geeignetem Befestigungs material z B D bel und Schrauben auf den Betonboden montieren Installationsrohre M20 oder M25 Zubeh r max 5 mm in den Ger teeinsatz einf hren...

Page 18: ...ch die feste Verankerung des Ger teeinsatzes im Estrich Estrich b ndig mit Oberkante Montageab deckung verlegen und an den Ger teeinsatz an arbeiten Elektroinstallation vornehmen Montageabdeckung und...

Page 19: ...ei eine Deh nungsfuge von 1 5 mm zum Ger teeinsatz belassen F r die Aussparung im Klappdeckel ein Passst ck zuschneiden und je nach St rke des Bodenbelages mit einer zus tzlichen Einlage b ndig mit de...

Page 20: ...r teeinsatz mit einem geeigneten flexiblen Material z B Silikon verf llen Der fertig montierte Ger teeinsatz Entsorgung Verpackung wie Hausm ll Ger teeinsatz wie Metallschrott Beachten Sie die rtliche...

Page 21: ...mm Gewicht ca 1 5 kg Einf hrungs ffnungen 4 x 25 mm M25 Mindesteinbautiefe 85 mm Max Einbauh he Estrich Systemboden Bodenbelag 105 mm Max H he Bodenbelag 15 mm Schutzklasse bei Schnurauslass geschlos...

Page 22: ......

Page 23: ...enings 4 for installation pipes M20 or M25 The frame 3 can be adjusted to the top edge of the floor covering using four height adjustment supports 5 The minimum installation depth is 95 mm the height...

Page 24: ...floor Opening and removing the hinged lid Open the hinged lid e g with a slotted screwdriver Turn the hinged lid as shown and then re move it Mounting the service unit If necessary remove the socket i...

Page 25: ...rth for a large opening 25 mm Mount the service unit on the concrete floor with suitable fastening materials e g an chors and bolts Insert the M20 or M25 installation pipe ac cessory max 5 mm into the...

Page 26: ...nchoring of the ser vice unit in the screed Lay the screen flush to the top edge of the mounting cover and work it up to the service unit Performing the electrical installation Remove the mounting cov...

Page 27: ...pansion joint of 1 5 mm to the service unit Cut out a key for the recess in the hinged lid and depending on the thickness of the floor covering stick it into the recess flush to the exterior frame of...

Page 28: ...n joint around the service unit using a suitable flexible material e g silicone The mounted service unit Disposal Packaging as household waste Service unit as scrap metal Comply with the local waste d...

Page 29: ...approx 1 5 kg Insertion openings 4 x 25 mm M25 Minimum installation depth 85 mm Max installation height Screed system floor floor covering 105 mm Max floor covering height 15 mm Protection class for...