OBO Bettermann C50-0-255 Installation Instructions Manual Download Page 5

Installation instructions

V50-...-280

OBO BETTERMANN GmbH & Co. KG

8

EN

Product description

Lightning current and surge protection device for 
equipotential  bonding  of  power  supply  systems 
according  to  VDE  0100-443  (IEC  60364-4-44) 
and for lightning protection equipotential bonding 
according  to  VDE  0185-305  (IEC  62305).  For 
mounting on hat rails and use in distributor hous-
ings. Arresters (Figure   

1

) can be connected 

individually and are encoded on the rear side, in 
order  to  avoid  incorrect  connection.  They  pos-
sess a thermodynamic cut-off unit and have an 
arresting  capacity  of  up  to  40  kA  (8/20)  and 
12.5 kA (10/350) per pole.
If  there  is  an  error,  the  visual  display  switches 
from grey to red (Figure  ).
With snap-on hat rail bracket (Figure   

2

).

The spark gap C50-0-255 is intended as an ar-
rester between the neutral conductor N and the 
protective conductor (PE conductor).

Only  V50-..+FS..:

  With  module  for  remote  sig-

nalling through potential-free changeover contact  
(Figure  ).

Target group

The device may only be mounted and connected 
by an electrical technician.

General safety information

•  Before working on power cables, ensure that 

they are de-energised and secure them against 
unintentional switch-on!

•  Do not carry out mounting work during a storm!
•  Comply with national laws and standards, e.g. 

VDE 0100-534 (HD 60364-5-534)!

Mounting and installation

The device can be installed in any position (e.g. 
vertical or horizontal).
Figure 

:  VDE  0100-534  (HD  60364-5-534) 

specifies that,

 

– in the case of single-branch wiring, 

1

 the total 

connection length a + b

 

– or, in the case of V wiring, 

2

 the connection 

length c

should  ideally  not  exceed  0.5  m,  but  never  ex-
ceed 1.0 m.
For  V  wiring,  use  the  connection  terminal,  item 
no. 5012 010.

 

Caution! Risk of overloading! 

The connection terminal 5012 010 is 
approved for a maximum current load ≤ 50 
A. 
Use a suitable back-up fuse!

EN

  Surge protection device

Item no.

Type

Product

Protection 

path

I

Total 8/20

I

Total 10/350

Circuit 

diagram

5093 508

V50-0-280

Single arrester*

5093 511

V50-3-280

Three-pole

L – PE/N

120 kA

37.5 kA

 

1

5093 513

V50-4-280

Four-pole

L – PE, N – PE

160 kA

50 kA

 

2

5093 522

V50-1+NPE-280

Single-pole with NPE

L – N, N – PE

50 kA

50 kA

 

1

5093 524

V50-2+NPE-280

Two-pole with NPE

L – N, N – PE

50 kA

50 kA

 

2

5093 526

V50-3+NPE-280

Three-pole with NPE

L – N, N – PE

50 kA

50 kA

 

3

5093 516

V50-3+FS-280

Three-pole with FS

L – PE/N

120 kA

37.5 kA

 

1

5093 518

V50-4+FS-280

4-pole with FS

L – PE, N – PE

160 kA

50 kA

 

2

5093 531 V50-1+NPE+FS-280 Single-pole with NPE/

FS

L – N, N – PE

50 kA

50 kA

 

1

5093 533 V50-3+NPE+FS-280 Three-pole with NPE/

FS

L – N, N – PE

50 kA

50 kA

 

3

5095 609

C50-0-255

Single arrester*

*

Figure   

1