OBLO Living AE100 User Manual Download Page 2

2.  Allow standalone network joining procedure:

1)  Press secondary button once in order to open 

standalone network. While network is opened, LED 

will blink green once in a second. 

2)  During this period of time, other devices can join 

High Load Switch’s network according to manufac-

turer’s instructions.  

Add new High Load Switch to existing High Load 
Switch’s network

In case you would like to add new High Load Switch to 

existing High Load Switch’s network, please follow next 

steps:

1.  On the existing High Load Switch press secondary 

button once to open ZigBee network. While network is 

opened, LED will blink green

2.  On the new High Load Switch press secondary button 

once to start joining procedure. During joining procedu-

re LED will blink red. After successful joining, LED will 

blink green NO longer than 3 minutes.

NOTE: 

In case you would like to assign a specific color of LED 

indicator to the particular High Load Switch status (on/

off), press and hold secondary button until LED indica-

tor starts changing its color in the following order – red, 

green, orange. Releasing the button to a particular color 

assigns that color to the current state of the device (e.g. if 

High Load Switch is on and you release the button while 

LED indicator is red, the LED will light red whenever High 

Load Switch is turned on). Make sure that High Load Swi-

tch’s network is closed during the operation. In case the 

network is opened, LED will blink green.

HIGH LOAD SWITCH AS A PART OF OBLO 
LIVING HOME AUTOMATION SYSTEM

In order to add High Load Switch to existing ZHA 1.2-com-

pliant system please follow next steps:

1.  On the gateway’s side initiate device inclusion proce-

dure according to gateway manufacturer’s instructions.

2.  On the High Load Switch press secondary button once 

to start joining procedure. During joining procedure LED 

will blink red.

3. After successful joining, LED will blink green no longer 

than 3 minutes.

USER DEFINED POWER LIMIT

NOTE: 

Setting of power limit can be done in case when High Load 

Switch is a part of standalone network (without home au-

tomation gateway as a central device). When High Load 

Switch is part of existing home automation system with 

gateway as a central device, the consumption can be adju-

sted via the client application.

Setting power limit to the maximum value

1.  Make sure that there is no device attached to High Load 

Switch.

2.  Press secondary button 5 times in order to set power 

limit to the maximum value (2200W).

Setting user defined power limit

1.  Attach the device with desired power consumption to 

High Load Switch.

2.  Make sure that High Load Switch is switched ON.

3. Press secondary button 5 times to set new power limit 

that is actually current power consumption of the de-

vice attached to High Load Switch. During the opera-

tion, LED will blink red and green simultaneously.

FACTORY RESET

In order to restore your High Load Switch to default fa-

ctory settings please follow next steps:

1.  Press secondary button 10 times to reset the device 

to factory settings.

2.  After successful operation, LED will change its color 

to red.

BUTTONS/FUNCTIONS

BUTTON Button 

Operation

Action

LED 

indication

MAIN

1 x short 

press

Power ON/OFF

Return to normal mode 

after overload

SECOND-

ARY

1 x short 

press

Open ZigBee 

network

Blink green 

(once in a 

second)

Join the  gateway’s 

network

Blink red

2 x short 

press

Pair as initiator

Blink green 

(twice in a 

second)

3 x short 

press

Pair as target

Blink orange

5 x short 

press

Set user defined power 

limit

Blink red and 

green simulta-

neously 

Long 

press 

(approx. 5 

seconds)

Create own ZigBee 

network

Red and green 

alternately

10 x short 

press

Factory reset

Red

TECHNICAL DATA

Communication Protocol

ZigBee

Range

Up to 30m (depending on 

your home’s construction)

Operating Temperature

0 - 40 °C

Protection Degree

IP20

Power

230V AC, 50Hz

Maximum Load

10A 230V AC

Dimensions 

Module W x H x D: 22.2 x 41.5 

x 47.1 mm

Mask W x H x D: 97.6 x 91.8 

x 47.1 mm

Mask with outlet W x H x D: 

120 x 91.8 x 47.1 mm

ATTENTION!

WARNING! 

Improper use or installation of the device 

can cause SERIOUS INJURY, DEATH or LOSS/DAM-

AGE OF PROPERTY.

WARNING! 

Using High Load Switch device in a 

manner other than outlined in this document is not 

allowed.

WARNING! 

Using more than one High Load Switch 

for controlling one consumer may cause permanent 

damage to the devices/wiring system.

WARNING! 

Turning the device on/off more often than 

once in two seconds can shorten its lifetime.

CAUTION! 

Do not try to open or to repair the device 

by yourself, otherwise SERIOUS INJURY, DEATH or 

LOSS/DAMAGE OF PROPERTY is possible.

IMPORTANT! 

Do not overload the device above the 

recommended limit.

!

!

!

!

!

!

ENG

USER MANUAL

Reviews: