2. Allow standalone network joining procedure:
1) Press secondary button once in order to open
standalone network. While network is opened, LED
will blink green once in a second.
2) During this period of time, other devices can join
High Load Switch’s network according to manufac-
turer’s instructions.
Add new High Load Switch to existing High Load
Switch’s network
In case you would like to add new High Load Switch to
existing High Load Switch’s network, please follow next
steps:
1. On the existing High Load Switch press secondary
button once to open ZigBee network. While network is
opened, LED will blink green
2. On the new High Load Switch press secondary button
once to start joining procedure. During joining procedu-
re LED will blink red. After successful joining, LED will
blink green NO longer than 3 minutes.
NOTE:
In case you would like to assign a specific color of LED
indicator to the particular High Load Switch status (on/
off), press and hold secondary button until LED indica-
tor starts changing its color in the following order – red,
green, orange. Releasing the button to a particular color
assigns that color to the current state of the device (e.g. if
High Load Switch is on and you release the button while
LED indicator is red, the LED will light red whenever High
Load Switch is turned on). Make sure that High Load Swi-
tch’s network is closed during the operation. In case the
network is opened, LED will blink green.
HIGH LOAD SWITCH AS A PART OF OBLO
LIVING HOME AUTOMATION SYSTEM
In order to add High Load Switch to existing ZHA 1.2-com-
pliant system please follow next steps:
1. On the gateway’s side initiate device inclusion proce-
dure according to gateway manufacturer’s instructions.
2. On the High Load Switch press secondary button once
to start joining procedure. During joining procedure LED
will blink red.
3. After successful joining, LED will blink green no longer
than 3 minutes.
USER DEFINED POWER LIMIT
NOTE:
Setting of power limit can be done in case when High Load
Switch is a part of standalone network (without home au-
tomation gateway as a central device). When High Load
Switch is part of existing home automation system with
gateway as a central device, the consumption can be adju-
sted via the client application.
Setting power limit to the maximum value
1. Make sure that there is no device attached to High Load
Switch.
2. Press secondary button 5 times in order to set power
limit to the maximum value (2200W).
Setting user defined power limit
1. Attach the device with desired power consumption to
High Load Switch.
2. Make sure that High Load Switch is switched ON.
3. Press secondary button 5 times to set new power limit
that is actually current power consumption of the de-
vice attached to High Load Switch. During the opera-
tion, LED will blink red and green simultaneously.
FACTORY RESET
In order to restore your High Load Switch to default fa-
ctory settings please follow next steps:
1. Press secondary button 10 times to reset the device
to factory settings.
2. After successful operation, LED will change its color
to red.
BUTTONS/FUNCTIONS
BUTTON Button
Operation
Action
LED
indication
MAIN
1 x short
press
Power ON/OFF
Return to normal mode
after overload
SECOND-
ARY
1 x short
press
Open ZigBee
network
Blink green
(once in a
second)
Join the gateway’s
network
Blink red
2 x short
press
Pair as initiator
Blink green
(twice in a
second)
3 x short
press
Pair as target
Blink orange
5 x short
press
Set user defined power
limit
Blink red and
green simulta-
neously
Long
press
(approx. 5
seconds)
Create own ZigBee
network
Red and green
alternately
10 x short
press
Factory reset
Red
TECHNICAL DATA
Communication Protocol
ZigBee
Range
Up to 30m (depending on
your home’s construction)
Operating Temperature
0 - 40 °C
Protection Degree
IP20
Power
230V AC, 50Hz
Maximum Load
10A 230V AC
Dimensions
Module W x H x D: 22.2 x 41.5
x 47.1 mm
Mask W x H x D: 97.6 x 91.8
x 47.1 mm
Mask with outlet W x H x D:
120 x 91.8 x 47.1 mm
ATTENTION!
WARNING!
Improper use or installation of the device
can cause SERIOUS INJURY, DEATH or LOSS/DAM-
AGE OF PROPERTY.
WARNING!
Using High Load Switch device in a
manner other than outlined in this document is not
allowed.
WARNING!
Using more than one High Load Switch
for controlling one consumer may cause permanent
damage to the devices/wiring system.
WARNING!
Turning the device on/off more often than
once in two seconds can shorten its lifetime.
CAUTION!
Do not try to open or to repair the device
by yourself, otherwise SERIOUS INJURY, DEATH or
LOSS/DAMAGE OF PROPERTY is possible.
IMPORTANT!
Do not overload the device above the
recommended limit.
!
!
!
!
!
!
ENG