1. TECHNICAL DATA

DETERMINED UNDER TEST CONDITIONS:

Nominal thermal output

8kW

Efficiency (Australian Test)

80%

Emissions (Australian Test)

1.1 g/Kg

8” Flue

465

1040

WEIGHT AND DIMENSIONS:

Dimensions Firebox

W465 x H1040 x D447mm

Firebox weight

114kg

Flue kit

Standard 6”/8”/10”

Summary of Contents for STUV 30 COMPACT

Page 1: ...1 TECHNICAL DATA 2 2 PRE INSTALLATION 3 3 INSTALLATION 5 4 OPERATION 9 5 TESTING 10 Keep for future use STUV 30 COMPACT MODEL SPECIFICATIONS...

Page 2: ...CHNICAL DATA DETERMINED UNDER TEST CONDITIONS Nominal thermal output 8kW Efficiency Australian Test 80 Emissions Australian Test 1 1 g Kg 8 Flue 465 1040 WEIGHT AND DIMENSIONS Dimensions Firebox W465...

Page 3: ...e internal flue and engage the firebox Ensure the floor has adequate protection CAUTION Using components or parts other than those provided by the manufacturer or modifying the specification of compon...

Page 4: ...uced with the application of heat shielding to walls in accordance to the Australian Building Code For information on heat shielding please contact our office on 03 9416 0400 or email info oblica com...

Page 5: ...Case 10 Outer Case 6 Active Flue 8 Flue 8 Flue CEILING RING RUBBER DEKTITE FLASHING 6 Active Flue Fireplace outlet 3 INSTALLATION 3 1 Installing flue kit Ensure flue is installed as per Australian sta...

Page 6: ...roof Alternatively there must be a minimum distance of 3 meters from any higher section of roof 40 cm 40 cm 40 cm 3 m 900 cm 3 m 900 cm 900 cm The top of the flue must be 900mm above the roofline Alt...

Page 7: ...combustiblefinishescanbeappliedtothefloorprotector tiles steelsheet lightconcrete etc If the combustible floor is installed on concrete you can replace the combustible material with non combustible m...

Page 8: ...ALLATION AND USER MANUAL Non combustible finish eg tiles Concrete Combustible floor eg timber 300mm 167 5 167 5 747mm 800mm Combustible floor eg Timber Floor protector FLOOR PROTECTOR LAID ON CONCRETE...

Page 9: ...s to start or rekindle the fire Do not use flammable liquids or aerosols in the vicinity of the fireplace when operating Do not store fuel within prescribed installation clearance distances The use of...

Page 10: ...ion of Power Output and Efficiency and AS NZS 4013 2014 for Flue Gas Emission using hardwood fuel ISSUE DATE 7 10 2015 INVESTIGATING OFFICER Steve Marland RESULTS The appliance particulate emission fa...