background image

11

English

Replace the felt whenever it becomes dirty, or when using a different scent of 

 

*

aroma oil or essential oil.
In addition to the felt that comes in the aroma case at purchase, two more pieces 

 

*

are included.
The felt cannot be washed and used again.

 

*

Insert the felt so that it fits under the tabs in the aroma case.

 

*

Wash the aroma case with a neutral detergent, and carefully wipe up any moisture 

 

*

before inserting it into the aroma base by following step 2.

Handling of aroma and essential oils

 Do not expose oils to open flame.

• 

Store out of the reach of children.

• 

If oils have spilled on clothes or other objects, rinse with a lot of water and allow to air dry. 

• 

Do not use a dryer. Doing so could cause the object to ignite.
If any oil gets on your hands, wash them immediately.

• 

For further details about handling aromatic and essential oils, refer to the manufacturer's 

• 

manual.

Cleaning and Storage

WARNING

After taking out the water tank, do not touch the metal parts inside the humidifier. 

• 

Doing so could result in injury or malfunction.
Before cleaning, press the stop button, unplug the power cord, and allow the inside 

• 

of the humidifier to cool (about 10 minutes). Otherwise, an electrical shock, burn, 
or other injury could occur.
After cleaning, always remount the parts in their original locations. Otherwise, an 

• 

injury or malfunction could result.

Cleaning the Humidifier

Fully drain the water left inside the humidifier.

When draining the water, be sure to drain it in the direction of the arrow shown 

 

*

on the humidifier body.
Draining the water in a direction different from the direction of the arrow can 
result in malfunction.

When the body gets dirty, wipe it clean with a soft cloth dipped in warm 
water and/or dish detergent and well wrung out. Then polish it gently 
with a dry cloth. (Do not rub hard on the plastic parts. Doing so may 
scratch them.)

If the water passage cover was removed, be sure to reattach it. Otherwise, this can 

 

*

cause water to leak.

Water passage cover

Always attach the water 
passage cover when using.

03-0̲MOD-KH1203US̲H5̲H5.indb   11

03-0̲MOD-KH1203US̲H5̲H5.indb   11

2013/11/08   21:28:15

2013/11/08   21:28:15

Summary of Contents for H5

Page 1: ...USER MANUAL...

Page 2: ...cts such as pins wires or other foreign objects in the gaps of this product This could result in an electrical shock or malfunction Do not allow children to use this product by themselves Keep out of...

Page 3: ...electronic devices that are sensitive to humidity near the humidifier Be careful that the product does not freeze If the product is placed in a location subject to freezing temperatures discard the wa...

Page 4: ...Parts and Their Functions Mist outlet Cover Mist hole Water tank handle Water tank Humidifier Air inlet bottom Front Water level indicator mood lamp Back Aroma case Power cord Power plug Water level...

Page 5: ...ic disc Water passage cover Inside of body Overflow pool Water passage cover Heater If the water passage cover is not attached correctly hot water can overflow from the humidifier body Insert the tabs...

Page 6: ...ndicated by the arrow Otherwise the water in the water tank and humidifier body could spill Be sure that the water passage cover is always attached when using Use without attaching the cover could res...

Page 7: ...3 Load the water tank into the humidifier and put the cover securely on the humidifier WARNING If you are going out or will be away from the humidifier for a long time unplug the power cord from the o...

Page 8: ...perature is expected to drop below 59 F or the humidity is expected to be above 60 when going to bed either set misting operation to L Low or SL Min or stop misting operation Even if the Power button...

Page 9: ...to 4H and is not lit when set to CONT continuous operation CONT continuous operation 2H off after 2 hrs 4H off after 4 hrs Timer setting Indicator color CONT continuous operation Off no color 2H Oran...

Page 10: ...nserting removing the felt case CAUTION Do not over fill with too much aroma oil or essential oil so that it overflows the aroma case Always wipe up any aroma oil or essential oil if it spills outside...

Page 11: ...ter taking out the water tank do not touch the metal parts inside the humidifier Doing so could result in injury or malfunction Before cleaning press the stop button unplug the power cord and allow th...

Page 12: ...r tank cap thoroughly shake the water tank and then drain Repeat this two or three times Be sure to always wash the water tank with water at room temperature Washing the water tank with hot water can...

Page 13: ...peration The ceramic disc must be replaced The ceramic disc has an expected service life of about 3 000 hours If the service life of the ceramic disc is exceeded the amount of mist generated can drop...

Page 14: ...s humidifying time Approx 8 hrs in High mode H Approx 13 hrs in Low mode L Approx 26 hrs in Super Low mode SL Tank capacity Approx 0 64 gallons Power cord length Approx 70 inches External dimensions A...

Page 15: ...nyone other than our FACTORY SERVICE CENTER Damage to OBJECTO equipment that has been improperly connected to the equipment of other b manufacturers Costs incurred in the shipping of OBJECTO products...

Reviews: