background image

OBID

® 

 classic-pro 

Installation 

ID CPRPOS 

 

FEIG ELECTRONIC GmbH 

Page 11 of 18 

ID CPRPOS User Manual-01.doc 

 

4.3. RS232 interface / Power supply 

 

 

Figure 7: Pin assignment RJ-12 jack 

 

Table 3: Pin assignment RJ-12 jack 

Pin No. 

Name 

Function 

Vcc 

5 V DC, approx. 500 mA 

RS232-RxD 

RS232 interface 

RS232-TxD 

nc 

not connected 

nc 

not connected 

GND 

Ground 

 

By using USB or Ethernet as communication interface the power supply unit included could be 
directly connected to the RJ-12 jack of the device. 

For usage of the RS232 interface a special RS232 connection cable is available (see 2.2. Available 
accessories and spare parts). In that case the included power supply unit has to be connected to 
the RJ-12 jack of the connection cable. The RJ-12 plug of the connection cable has to be connect-
ed to the RJ-12 jack of the device. 

 

CAUTION: 

The device has to be supplied by a limited power supply (e.g. NEC Class 2/LPS power sup-
ply) according IEC EN 60950, only! 

Reversing the polarity of the supply voltage may destroy the device. 

Summary of Contents for ID CPRPOS

Page 1: ...INSTALLATION final public B 2015 07 27 ID CPRPOS User Manual 01 doc ID CPRPOS Card reader for contactless and contact smart cards ...

Page 2: ...useful tips The instructions given in this manual are based on advantageous boundary conditions FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and does not give any guaranty for the functionality of the complete system which incorporates the subject of this document FEIG ELECTRONIC call explicit attention that devices which are subject of this d...

Page 3: ...s of the ID CPRPOS 5 2 1 Scope of delivery 5 2 2 Available accessories and spare parts 6 3 Dimensions 7 4 Connections 8 4 1 Ethernet interface 9 4 2 USB interface 10 4 3 RS232 interface Power supply 11 5 Display and LED 12 5 1 Display 12 5 2 LED 13 6 Installation of a Secure Access Module SAM 14 7 Radio Approvals 15 7 1 Europe CE 15 7 2 USA FCC and Canada IC 15 8 Technical Data 17 ...

Page 4: ...re valid for the device The manufacturer shall not be held legally responsible for inaccuracies errors or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device Repairs may only be executed by the manufacturer Installation operation and maintenance procedures should only be carried out by qualified personnel Use of the device and its instal...

Page 5: ...rface for ID 1 sized smart cards the ID CPRPOS has one SAM socket for ID 000 sized smart cards available The ID CPRPOS can be connected and controlled by a host system via its RS232 USB or Ether net interface A connected host system is able to use the ID CPRPOS to communicate with smart cards and to control the user guidance via display LED and buzzer The reader could be config ured by the connect...

Page 6: ...accessories and spare parts Order Number Article Description 4219 000 00 OBID myAXXESS ID NET 5V EU Power supply unit 5 V DC 1 A Length of the connection cable 1 5 m 4218 000 00 ID CAB RS C RS232 connection cable incl connector for power supply Host connector D SUB 9 poles Device connector RJ 12 plug 6 poles Power supply connector RJ 12 jack 6 poles Length 2 0 m ...

Page 7: ...ual 01 doc 3 Dimensions The ID CPRPOS is designed as desktop device Its small form factor offers the possibility to place the reader directly on a sales counter or at a cashier station Due to its rubber feet the reader is suitable for slippery undergrounds Figure 2 Top view Figure 3 Side view ...

Page 8: ... 01 doc 4 Connections Figure 4 ID CPRPOS position of the connectors Ethernet interface RJ 45 USB interface Mini USB RS232 interface and power supply RJ 12 NOTE Only one host interface should be used at the same time The usage of more than one host interface at the same time can cause malfunctions ...

Page 9: ...le operation at 10 Mbps and 100 Mbps The prerequisite for using TCP IP protocol is that each device has a unique address on the net work All readers have a factory set IP address The communication parameter could be configured user defined Table 2 Standard factory configuration of the ethernet interface Network Address IP address 192 168 10 10 Subnet mask 255 255 0 0 Port 10001 DHCP OFF NOTE The r...

Page 10: ...SB slave In addition the ID CPRPOS offers the possibility to connect an external USB memory stick to the electronic unit by means of a USB on the go adaptor ID CPRPOS is USB master Figure 5 USB mini jack Figure 6 USB mini cable for host connection With the delivered wire strap the USB cable could be fixed at the housing and a strain relief for the cable connection could be established NOTE The dev...

Page 11: ...wer supply unit included could be directly connected to the RJ 12 jack of the device For usage of the RS232 interface a special RS232 connection cable is available see 2 2 Available accessories and spare parts In that case the included power supply unit has to be connected to the RJ 12 jack of the connection cable The RJ 12 plug of the connection cable has to be connect ed to the RJ 12 jack of the...

Page 12: ...ed host system can send text messages via the interfaces RS232 USB and Ethernet to the integrated graphic display to realise a user guidance Customised graphics monochrome Bit maps with size 128 x 64 dots e g company logo or advertisement could be stored in the device and could be shown outside the user guidance For further information please read the system manual H31010 xx ID B pdf Note With tem...

Page 13: ... The device is equipped with 1 green 1 yellow and 1 red LED Figure 9 Position of the LED on the ID CPRPOS Table 4 LED on the ID CPRPOS LED Description green Communication with a contactless smart card red Error yellow In table 4 the meaning of the LEDs with standard configuration is described The LED could be controlled by a connected host system and a customized LED indication is possible ...

Page 14: ... which the SAM can be plugged in To open the socket the cover of the socket has to be pushed slightly in direction OPEN Afterwards it can be lifted The SAM has to be inserted according Figure 11 Installation of a SAM The golden contacts of the chips are facing towards the PCB when the socket is closed After the socket is closed it has to be locked again by pushing it slightly towards in direction ...

Page 15: ...ission Rules permitting the operation of this device This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energ...

Page 16: ...ization to operate this equipment Installation with FCC IC Approval FCC IC NOTICE To comply with FCC Part 15 Rules in the United States with IC Radio Stand ards in Canada the system must be professionally installed to ensure compliance with the Part 15 certification IC certification It is the responsibility of the operator and professional installer to en sure that only certified systems are deplo...

Page 17: ...ernal Supported transponder types contactless Read and Write ISO IEC 14443 4 NFC card emulation mode Type 1 2 4 mifare classic mifare PLUS mifare DESFire mifare ultralight my d move my d prox imity SR176 SRIx Calypso Innovatron radio protocol Contact smart card interface ID 1 tested according to EMVCo Contact Level 1 landing contacts 200 000 cycles ID 000 SAM socket ISO 7816 9600 up to 625 000 Bit...

Page 18: ...Radio Approval Europe EN 300 330 USA FCC 47 CFR Part 15 Canada IC RSS Gen RSS 210 EMC EN 301 489 Environmental shock vibration climate IEC 60068 Health and Safety EN 60950 EN 50364 Waste and Hazardous Substances WEEE 2002 96 EC RoHS 2011 65 EC Function tested according to EMVCo Contactless Contact Level 1 ...

Reviews: