9.1. Connections
The connection of the ID CPR50.10-xE is carried out via a connection board which will be snapped
into the housing.
Fig. 6: ID CPR50.10-xE connection board with LSA terminal X2
9.1.1. LSA Connection X2 for TCP/IP Interface
The connection of the ID MAX50.10-E with the Ethernet and PoE power supply will be carried out
by a LSA terminal connector X2. For applying the CAT5 cable on to the LSA connector a special
LSA punch down tool must be used.
There are existing two different ways for the connection of a CAT5 cable, EIA/TIA T568A and
EIA/TIA T568B. The typical color coding is shown in the table below.
X2
Signal
EIA/TIA T568A
EIA/TIA T568B
1
Tx D1+
Green striped
Orange Striped
2
Tx D1-
Green
Orange
3
Rx D2+
Orange Striped
Green striped
4
BI D3+
Blue
Blue
5
BI D3-
Blue Striped
Blue Striped
6
Rx D2-
Orange
Green
7
BI D4+
Brown Striped
Brown Striped
8
BI D4-
Brown
Brown
Table 1 Connection of the LSA Connector X2
Note:
It is recommended to use a shielded twisted pair STP CAT5 cable.