OBERON 1043-ARAP5 Series Installation Manual Download Page 2

Installation Guide / 

Guía de instalación

 

for Oberon Model 1043

-

ARAP5XX Series Aruba

 

para Modelo Oberon 1043

-

ARAP5XX Serie Aruba

 

 

 

 

Mounting Solutions for WiFi Access Points

 

"Oberon" and all other marks where denoted are trademarks of Oberon Inc.  

©

1999

-

2020 Oberon Incorporated. All rights reserved.

 

"Oberon" y todas las demás marcas donde se denotan son marcas comerciales de Oberon Inc.  ©1999

-

2020 Oberon Incorporated. Todos los derechos reserve.

 

EPN 3892, 4011, 4062, & 4194 

-

 Rev. 7/31/2020

 

The torsion springs that are used to secure the trim assembly to the tile 
bridge are shipped separately (to prevent damage) and must be installed 
prior to the first use. To install torsion springs, first detach the mounting 
plate from the trim face. Depending on the trim model, this can be done 
either by removing the two (2) or four (4) hex nuts.

 

Los resortes de torsión que se usan para asegurar el conjunto de moldu-
ra al puente de baldosas se envían por separado (para evitar daños) y 
deben instalarse antes del primer uso. Para instalar muelles de torsión, 
primero separe la placa de montaje de la cara de la moldura. Dependien-
do del modelo de acabado, esto se puede hacer quitando las dos (2) o 
cuatro (4) tuercas hexagonales.

 

Install the two (2) torsion springs by: A pinching the tips together, and B 
inserting the tips into the rectangular openings on each end of the 
mounting bracket.

 

Instale los dos (2) muelles de torsión: A apretando las puntas y B in-
sertando las puntas en las aberturas rectangulares en cada extremo del 
soporte de montaje.

 

3

 

4

 

A

 

B

 

 

 

Reassemble the trim by attaching the trim piece which was previously re-
moved by inserting the studs into the slotted holes and installing the hex 
nuts.

 

Vuelva a ensamblar la moldura uniendo la pieza de moldura que se retiró 
previamente insertando los pernos en los orificios ranurados e instalando 
las tuercas hexagonales.

 

5

 

First, remove the metal bracket that ships with Aruba AP from the back side 
of the AP by removing the two (2) screws that hold it in place. 

 

To install the Aruba 5XX series AP, insert the access point into the opening 
on the door, aligning it so that the activity lights of the AP are aligned with 
the small cutout nearest the lock of the door. Hold the access point in place 
while pressing and turning the captive screws to engage them with the 
screw holes on the back of the Aruba AP.

 

Primero, retire el soporte de metal que se envía con el AP Aruba desde la 
parte posterior del AP quitando los dos (2) tornillos que lo sujetan en su 
lugar.

 

Para instalar el AP Aruba serie 5XX, inserte el punto de acceso en la aber-
tura de la puerta, alineándolo para que las luces de actividad del AP estén 
alineadas con el pequeño recorte más cercano a la cerradura de la puerta. 
Mantenga el punto de acceso en su lugar mientras presiona y gira los tornil-
los cautivos para engancharlos con los orificios para tornillos en la parte 
posterior del AP Aruba.

 

6

 

Place the

 enclosure assembly

 on the work surface. Remove one of the 1” 

trade size hole cover on the side of the enclosure and install the 1” trade 
size conduit connector (the side on which the trade size cable clamp is to be 
installed will be determined by the location the enclosure is to be installed 
and direction from which conduit will be brought into the enclosure) 

 

NOTE: 

The sheetrock that will be installed over the access point enclosure 

will require a 11.25” x 11.25” opening be cut to accommodate the enclosure 
(special cutting tools may be required. Adjust the location of the enclosure 
on the studs in a way that assures that the bottom surface of the enclosure 
is flush with or slightly above the bottom surface of the sheetrock.

 

NOTE: 

A surface mount box (or biscuit jack) and equipment cord can be 

conveniently mounted inside the Model 1043. (Non

-

plenum rated cables can 

be used inside a plenum rated enclosure). Use an adhesive backed surface 
mount box. Consider bend radius of horizontal cable and equipment cord 
when attaching the surface mount box. 

 

Coloque el ensamblaje del gabinete en la superficie de trabajo. Retire una 
de las cubiertas de orificio de tamaño comercial de 1 "en el lado del gabi-
nete e instale el conector del conducto de tamaño comercial de 1" (el lado 
en el que se instalará la abrazadera del cable de tamaño comercial se de-
terminará según la ubicación en la que se ubicará el gabinete instalado y la 
dirección desde la cual se llevará el conducto al recinto)

 

NOTA: 

La placa de yeso que se instalará sobre el gabinete del punto de 

acceso requerirá que se corte una abertura de 11.25 "x 11.25" para acomo-
dar el gabinete (es posible que se requieran herramientas de corte especial-
es. Ajuste la ubicación del gabinete en los pernos de una manera que 
asegure que la superficie inferior del recinto está al ras o ligeramente por 
encima de la superficie inferior de la placa de yeso.

 

1

 

2

 

Clamp the firestop grommet around the cable far enough to allow attach-
ment to the access point (8" 

-

 10"). Insert the grommet into the conduit 

fitting.

 

Sujete la arandela cortafuegos alrededor del cable lo suficiente para 
permitir la fijación al punto de acceso (8" 

-

 10"). Inserte la arandela en el 

accesorio del conducto. 

 

 

NOTA: 

Una caja de montaje en superficie (o un conector para galletas) y 

un cable de equipo se pueden montar convenientemente dentro del 
Modelo 1043. (Los cables sin capacidad de plenum se pueden usar den-
tro de un recinto con capacidad de plenum) Use una caja de montaje en 
superficie con respaldo adhesivo. Considere el radio de curvatura del 
cable horizontal y del cable del equipo cuando conecte la caja de mon-
taje en superficie.

 

1 cont.

 

Reviews: