background image

Securely tighten the screws, being sure that the screw is inserted directly into the joist*. 
 
*NOTE: Alternatively, if no joists are available for mounting, drywall anchors may be used.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 6 

 
 
Page 4 

 

 

Figure 5 - 

Ceiling installation. 

MODEL 1027-00 

Installation Instructions 

 

**** WARNING **** 

 

Please thoroughly read the product warning below 

before installation to provide for a safe work 

environment. 

 

1.  Ceiling mounted products should be installed in accordance with National Electric Code paragraphs 300.10 (Electrical 

Continuity of Metal Raceways and Enclosures) and 300.11 (Securing and Supporting). Independent support wires or 
other means must be used for the installation of this product in the ceiling. Acoustical, suspended, false, drop and 
concealed spline ceiling grid work is not designed to support the weight of this product. Oberon’s ceiling mounted 
products have four support wire tabs on the back box. These tabs shall be used for supporting the product with 
independent support wires, wire rope, threaded rod, or other secure support means of adequate gauge and fire 
resistance. 

 

2.  When closing the enclosure access door, be sure that the cam lock is completely engaged to prevent the access door 

from accidentally swinging open. 

 

3.  When opening the enclosure door, be sure to support the door to prevent the door from accidentally falling open. 
 
4.  This enclosure has a maximum operating ambient of 55º C (131º F), the temperature within the enclosure may not 

exceed this temperature, depending on power dissipation within enclosure. 

 
5.  A minimum air clearance of 1“ between the housing of the access point and the enclosure side walls must be 

maintained for the safe operation of the equipment. 

 
6.  This product is intended to be installed by trained personnel. 
 
7.  Only Listed ITE shall be installed within the enclosure. 
 
8.  This product is to be repaired by personnel trained by the manufacturer or returned to the manufacturer for repair or 

replacement. 

 
9.  Maximum weight to be installed in the unit is 25 lbs. 
 
10. All knockouts, openings, and holes shall be sealed with a plug constructed of metal, or a non-metal material that 

complies with UL 2043 or UL 1479. 

 
11.  All unused mounting holes should be sealed with tape or other material that complies with UL 1479. 
 
12. If AC power is used inside the enclosure, connect the ground wire to the green ground screw located near the 

knockout in the backbox. 

Page 1 

Reviews: