Section 4: Set-up guide for bottle filler electronics
• Units - Gallons
• Unfiltered unit
• Flow Meter = Rate Selected
• Filter Capacity = 1250 gallons [4731 liters] for a VersaFilter
•
Pushbutton
Factory default program settings are:
• Bottle Count = 0.5L (1 Bottle)
• Flow Rate = 1.2 GPM
• 20 second maximum dispense time
To change the program settings, follow these steps:
21
Display
Action
000000000
BOTTLES REUSED
(Home Screen)
Depress button for 3 seconds to enter into the following menu settings and make changes.
Note: at anytime it will exit menu and save settings when idle for 10 seconds (no button
press) and revert back to Home Screen.
LTR/GAL
GAL
Depress button 3 seconds to change from Gallons to Liters,
or momentary press to advance to next menu.
UNFILT/FILT?
UNFILT UNIT
Depress button 3 seconds to change from Unfiltered to Filtered unit,
or momentary press to advance to next menu.
FLOW METER?
RATE SELECTED
Depress button 3 seconds to change from Rate Selected to (Flow) Meter Enabled,
or momentary press to advance to next menu. Not included on all models.
SELECT RATE
1.2 GPM UNIT
To change flow rate, momentarily depress button to change whole gallon digit.
Hold button 3 seconds to advance to TENTHS of gallon digit.
Depress momentarily to change the digit.
Hold button 3 seconds to advance to the next menu.
RESET 00000000
GALLON CNT
[LTR COUNT]
Depress button for 3 seconds to reset Gallon or Liter count,
or momentary press to advance to next menu.
FILT CAPAC
OF 1250 GAL
[4731 LTR]
Depress button for 3 seconds to change filter capacity to 3000 GAL [11355 liters] for
Versafilter II or Galaxi green filter.
Or momentary press to advance to next menu.
3 sec rule?
0.5L
Depress button for 3 seconds to switch from 0.5L bottle to 3 sec rule,
or momentary press to advance to next menu.
(The 3 Sec rule increases the bottle count based on a 3 second dispense.)
Reset 00000000
BOT COUNT?
Depress button for 3 seconds to reset (Home Screen) BOTTLES REUSED count,
or momentary press to advance to next menu.
Bot Filler
Set_time: 20 s
Depress button for 3 seconds to change maximum dispense time to 10, 20 or 30 seconds,
or momentary press to advance to next menu.
RUN CAL
AGAIN?
Depress button 3 seconds to run calibration again,
or momentary press to advance to next menu.