background image

2 of 7 

 

requirements.  Plug power supply cord into wall outlet.  The rear most 1-3/8 diameter knockout in frame bottom is for 
an externally located electrical supply.  Make sure knockout hole edge is smooth and free of any burrs.  Use of Heyco 
bushing #2184 in knocked out hole is recommended to prevent damage to service cord and to close up excess opening 
around cord.  Route cord so it does not interfere with ADA* space requirements. 

14.

 

To fill cold water tank on water cooler, open water supply line shut-off and push any one of front push pads to allow 
water  to  flow  to  bubbler.    On  TM  and  TT  models,  actuate  solenoid  by  holding  one  hand  approximately  1”  from 
infrared sensor (under front edge of shelf). Run water until stream is free of bubbles.  After approximately 20 seconds 
run  time,  solenoid  valve  will  automatically  shut  off.    To  reactivate,  move  hand  away  for  an  instant  and  then  again 
place it in front of sensor. 

15.

 

To Adjust Bubbler stream: 

All models are equipped with a cartridge regulator.  The standard push pad and electric eye models have a slot at 
back  of  underside  of  shelf.    Insert  a  screwdriver  in  this  slot  to  adjust  regulator.    Turn  adjustment  clockwise  to 
increase stream height.  To access PGV8ACSL and PGVF8ACSL adjustment, remove the Bezel and Button from 
front of cooler. 

14.

 

On electric eye equipped models (TM and TT models), place and then hold hand approximately 1” from sensor (under 
front edge of shelf) to actuate solenoid valve.  After approximately 20 seconds run time, solenoid valve will 
automatically shut off.  To reactivate, move hand away for an instant and then again place it in front of sensor. Every 
time the power reboots, the bottle sensor automatically recalibrates itself. IT IS IMPORTANT TO HAVE NO 
OBJECT PRESENT NEAR THE SENSOR EVERYTIME THE UNIT REBOOTS SO THAT SENSOR 
CALIBRATION IS DONE CORRECTLY. 

C.

 

MAINTENANCE 
The only maintenance operation required is the removal of dirt and lint from the condenser of the water cooler.  Inspection 
should be made at 3-month intervals.  Disconnect the power supply cord, then clean the condenser with a small stiff non-
wire brush when required.  Observance of this procedure will ensure adequate air circulation through the condenser, so 
operation is efficient and economical. 

D.

 

OVERLOAD PROTECTION (water cooler) 
The compressor motor, where used, is equipped with an automatic reset protector which will disconnect the motor from 
the line in case of an overload. 

E.

 

LUBRICATION (water cooler) 
This unit is equipped with a hermetically sealed compressor and requires no additional lubrication.  The fan motor on this 
unit seldom needs oiling, but if required, a few drops of SAE 10 oil should be used. 
 

F.

 

TO DISCONTINUE USE OF WATER COOLER AND WATER FOUNTAIN 
1.

 

Close water shut off valve. 

2.

 

Provide container to catch water to be drained. 

3.

 

On push button model, disconnect power supply cord then disconnect water supply line at shut off valve.  Route water 
supply line to container and actuate push button.  If this drains too slowly for you, prepare 3/8” ID tube or 3/8” OD 
tube with quick-connect fitting and remove screw plug in tank drain.  Slide tube over drain and route to container.  
Replace screw plug when draining is complete.  Do not over-tighten.  O-ring only needs to be snug to seal. 

4.

 

On TM and TT models, disconnect water supply line at shut off valve.   Place water supply line in container and 
actuate solenoid as explained in Step B12.  If this drains too slowly for you, disconnect power supply cord and prepare 
3/8” ID tube or 3/8” OD tube with quick-connect fitting.  Remove screw plug in tank drain.  Slide tube over drain and 
route to container.  Replace screw plug when draining is complete.  Do not over-tighten.  O-ring only needs to be snug 
to seal. 

5.

 

ALWAYS  DRAIN  ALL  WATER  WHEN  FREEZING  TEMPERATURES  ARE  ANTICIPATED  AND  BEFORE 
SHIPPING THE WATER COOLER. 

*American With Disabilities Act 

WARNING 

The  warranty  and  the  Underwriters'  Laboratory  listing  for  this  machine  are  automatically  voided  if  this  machine  is  altered,  modified,  or 
combined  with  any  other  machine  or  device.    Alteration  or  modification  of  this  machine  may  cause  serious  flooding  and/or  hazardous 
electrical shock or fire. 
EXCEPT  AS  SET  FORTH  HEREIN,  THE  MANUFACTURER  MAKES  NO  OTHER  WARRANTY,  GUARANTEE  OR 
AGREEMENT 

EXPRESSED, 

IMPLIED 

OR 

STATUTORY, 

INCLUDING 

ANY 

IMPLIED 

WARRANTY 

OR 

MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. 

Reviews: