4. QUASAR UV-C LED OPERATION
6
Condition
Orange
Green
Yellow
Red
Blue
LED Color
While dispensing, UVC
temperature is too high.
Ensure water supply is ON.
If initial start-up: Activate the
bottle filler to dispense water.
LED will turn BLUE when water
flows.
Action
Display
“UVC OFF- TURN
ON WATER SUPPLY”
Standby mode – filter life
<80% used.
No action needed.
“BOTTLES SAVED”
Standby mode – filter life
>80% used but <100%.
Order new filter.
“BOTTLES SAVED”
Standby mode – filter life
=100% used.
Replace the filter.
“BOTTLES SAVED”
Orange
Dispensing – bottle sensed
by IR sensor and UVC
operating properly.
No action needed.
“UVC DISINFECTION
IN PROCESS”
Water cannot be dispensed
(unless Override Stop
Dispense is selected in the
program menu).
Check electrical connections
to UVC and reset power first.
Replace UVC if necessary.
“UVC REQUIRES
SERVICE”
(Remains ON even in
standby.)
Display
LED Indicator