background image

4.  QUASAR UV-C LED OPERATION

6

Condition

Orange

Green

Yellow

Red

Blue

LED Color

While dispensing, UVC 

temperature is too high.

Ensure water supply is ON.

If initial start-up: Activate the

bottle filler to dispense water.

LED will turn BLUE when water 

flows.

Action

Display

“UVC OFF- TURN 

ON WATER SUPPLY”

Standby mode – filter life

<80% used.

No action needed.

“BOTTLES SAVED”

Standby mode – filter life

>80% used but <100%.

Order new filter.

“BOTTLES SAVED”

Standby mode – filter life

=100% used.

Replace the filter.

“BOTTLES SAVED”

Orange

Dispensing – bottle sensed

by IR sensor and UVC

operating properly.

No action needed.

“UVC DISINFECTION

IN PROCESS”

Water cannot be dispensed 

(unless Override Stop 

Dispense is selected in the 

program menu).

Check electrical connections

to UVC and reset power first.

Replace UVC if necessary.

“UVC REQUIRES

SERVICE”

(Remains ON even in 

standby.)

Display

LED Indicator

Summary of Contents for PCPEBQ

Page 1: ...LER WITH QUASAR UV C LED Installation Instructions For UNFILTERED PCPEBQ PCPEBQY 230V PCP10EBQ PCP10EBQY 230V FILTERED PF2CPEBQ PF2CP10EBQ OASIS International 222 East Campus View Blvd Columbus OH 43235 614 861 1350 www oasiscoolers com 1 ...

Page 2: ... STARTED 6 PROPER QUICK CONNECT FITTING CONNECTION INSTRUCTIONS 7 INSTALLATION 8 SET UP GUIDE FOR DISPENSER PCB ELECTRONICS 2 1 PRODUCT SPECIFICATIONS Dimensions Depth 13 11 16 348 mm Width 12 1 8 307 8mm Height 49 11 16 1262 mm Refrigerant R 134a Input Voltage 115 VAC 60 HZ or 220 240 VAC 50 60HZ See Data Plate ...

Page 3: ...ROUGHING IN AND DIMENSIONAL DRAWING 3 ...

Page 4: ...IVATE ELECTRICAL EYE SENSOR WITHOUT RUNNING WATER THROUGH THE UVC MODULE DOING SO WILL DAMAGE THE UV C LEDS SEE SECTION 4 STEP 2e and SECTION 7 STEPS 13 18 2 IMPORTANT REQUIREMENTS 4 BEFORE YOU START USING THIS WATER DISPENSER PLEASE READ THE FOLLOWING INSTRUCTIONS CAREFULLY The unit must be connected to a 115 VAC GFCI or 230VAC power supply as listed on the equipment data label The unit must be p...

Page 5: ...R is not working properly then the LED light on the front of the alcove near the top will be ORANGE The light will remain ON and the system will not allow water to be dispensed until the problem is resolved unless Override Stop Dispense is selected in the program menu See SET UP GUIDE FOR QUASAR PCB ELECTRONICS for instructions on how to change this setting e IMPORTANT Never operate the QUASAR wit...

Page 6: ... No action needed BOTTLES SAVED Standby mode filter life 80 used but 100 Order new filter BOTTLES SAVED Standby mode filter life 100 used Replace the filter BOTTLES SAVED Orange Dispensing bottle sensed by IR sensor and UVC operating properly No action needed UVC DISINFECTION IN PROCESS Water cannot be dispensed unless Override Stop Dispense is selected in the program menu Check electrical connect...

Page 7: ...DRAINPIPES DRAIN ELBOWS and P TRAP NOT SHOWN d VERSAFILTER III FILTERED MODELS ONLY e REMEDI FILTER FILTERED MODELS ONLY 7 VERSAFILTER III filtered models only CONTACTLESS BOTTLE FILLER STABILIZER BRACKET Remedi filter element filtered models only NOTE This comes installed in the cooler ...

Page 8: ... direction when routing the tubing Sharp turns could cause the tubing to kink which reduces its flow capacity and or stops it completely Fittings consist of two parts a body and a collet See figure below To install a tube push it through the collet until it seats firmly at the bottom of the fitting To remove a tube push and hold the collet against the body while pulling the tube out Pushing the tu...

Page 9: ...15 TORX SCREWS QTY 2 9 STEP 1 2 1 Carefully unpack Water Dispenser 2 Remove Front Panel by removing the 2 screws at the bottom of the panel on the sides Carefully remove Drainpipes Drain Elbows and P Trap packaged inside unit See Diagram 1 and 2 ...

Page 10: ... to Driptray Tailpiece 4 Locate the Snap Bushing in the back of the cabinet and feed 1 1 2 OD P Trap through the hole See Diagram 3 and 4 7 INSTALLATION 10 DIAGRAM 3 DIAGRAM 4 DRIPTRAY TAILPIECE DRIPTRAY TAILPIECE DRAIN ELBOW QTY 2 P TRAP DRAINPIPE QTY 2 ...

Page 11: ...he filter so that the rectangular lug on top of the filter faces forward 7 Push the filter up into the filter housing and rotate the filter one quarter turn to the right until it stops turning Refer to Diagram 5 7 INSTALLATION DIAGRAM 5 Remedi Filter shown in Green Filter housing was installed at the factory 11 VERSAFILTER III Lug IMPORTANT When replacing filter cartridge turn OFF water supply Dep...

Page 12: ...onnect fittings IMPORTANT Before connecting water supply to dispenser flush building water supply 9 Connect 1 1 2 OD drainpipe to Elbow Coupling not provided Connect to building drain 10 Attach stabilizing bracket to the unit with screws provided Then secure the bracket to the wall with wall anchors provided by others CONNECT WATER SUPPLY Rear View CONNECT DRAIN ATTACH STABILIZER BRACKET DIAGRAM 6...

Page 13: ...NSING FLUSHING FILTERS FILTER MODEL ONLY Place a container in the alcove to activate water dispense The flow of water will be delayed until the filter fills with water Flush water through the system until the water becomes clear 14 Check system for any leaks 15 Place bottle in alcove to purge additional air in Cooling Tank and water lines The Water Dispenser sensor will run for 20 seconds and shut...

Page 14: ...on digit Hold button 3 seconds to advance to TENTHS of gallon digit Depress momentarily to change the digit Hold button 3 seconds to advance to the next menu RESET 00000000 GALLON COUNT LTR COUNT Depress button for 3 seconds to reset water usage count or momentary press to advance to next menu FILT CAPAC OF 4750 GAL 18000 LTR Depress button for 3 seconds to change filter capacity to 1250 GAL 5000 ...