background image

GENERAL INFORMATION ABOUT CNG / WARNINGS

• CNG is compressed natural gas that is transported and stored under high pressure. It is lighter 

than air. Commercial CNG is odorised to enable detection by its sulfurous smell. Small leakages 

typically cannot be seen and merely detected by its smell. When exposed to the atmosphere It 

has an expanding factor proportional to the Service Pressure, e.g. 1:207 at a Service Pressure of 

207 bar: one liter of compressed gas corresponds to 207 liter of flammable gas.

High pressure gas and gas equipment can cause serious harm to both infrastructure and  

personnel if safety precautions are not followed

 

A small gas release upon uncoupling is normal – but uncontrolled gas release to the 

atmosphere must be avoided. If you suspect a leakage: stop refuelling immediately, use 

the emergency button to shut off the dispenser, immediately evacuate the area and inform 

station personnel.

• CNG/Natural Gas is extremely flammable: 

 

Open fires, smoking, sources of static electricity and the use of mobile phones or other 

electric devices is prohibited in the area of gas transfer. Turn off vehicle engine before 

refuelling.

• Failure or improper use of this product can cause death, personal injury and property 

damage.

 

CNG is extremely cold when released to the air (depressurised).

INSTALLATION

High pressure gas and gas equipment can cause serious harm to both infrastructure and personnel 

if safety precautions are not followed.

Oasis recommends the use of personal protective equipment ( PPE ) when working with high pres-

sured gases ( CNG ) in accordance to the relevant health and safety regulations:

 

Foot Protection  

 Hearing Protection 

Safety Helmets 

 Hand Protection 

Safety Glasses

3

DRAFT

Summary of Contents for N-CNG P30

Page 1: ...ENGINEERING LIMITED 129 Birch Avenue Tauranga New Zealand Tel 64 07 928 38 08 Email info oasisngv com N CNG P30 P36 CSA ANSI NGV 1 2017 ISO 14469 2017 CNG NOZZLE INSTALLATION AND OPERATING MANUAL 22...

Page 2: ...for public and private CNG refuelling stations The nozzle is designed to only allow gas to flow when it is correctly coupled and to not allow uncoupling from the vehicle refuelling receptacle when the...

Page 3: ...f you suspect a leakage stop refuelling immediately use the emergency button to shut off the dispenser immediately evacuate the area and inform station personnel CNG Natural Gas is extremely flammable...

Page 4: ...alve or damage vehicle motor parts This device complies with CSA ANSI NGV 1 2017 and ISO 14469 2017 The installation of this device shall conform to the requirements of the authorities having jurisdic...

Page 5: ...escaping gas A small gas release upon uncoupling is normal If uncontrolled and or permanent gas release to the atmosphere occurs immediately stop fuelling If the leakage continues push emergency butto...

Page 6: ...vehicle filling point OFF On completion of refuelling squeeze and release lever Latch will automatically release Fuelling should start automati cally OR has to be activated at the dispenser Please fol...

Page 7: ...ny other common sense procedures generally applicable to equipment of this type The foregoing limitation extends to damages to person or property caused by the unit or damages resulting from the inabi...

Page 8: ...serial number on the CNG nozzle bodies Excluded are nozzles and parts subjected to wear and tear and damages caused by improper use for example the use with unsuitable media Furthermore excluded are...

Reviews: