HMI REMOTE LOW PRESSURE CHEMICAL/RINSE SCREEN
Each toggle button works independently. To turn on a chemical, air,
solenoid valve, or pump you must toggle each function individually.
For example; If you wish to test operation of Presoak 1 you would
perform the following steps:
1) Press the “Chem” toggle button next to Presoak 1.
2) Press the “Air” toggle button next to Presoak 1.
3) Press the “Pump” toggle button next to Aux Chem Pump
4) Press the “Valve” toggle button next to Aux Chem Pump
NOTE:
All remote functions are toggled “off” in the illustration above.
*Remember to toggle remote functions “off” before resuming normal
operation of the machine. The machine cannot be “reset” with remote
functions toggled “on”.
*Remember to toggle “Remote” button “off” when exiting remote
mode. The system will not “reset” with the remote button toggled
“on”.