31.

 

Use the (+) or (-) button to set the total number of months you wish to monitor up to.  The maximum number you 
can enter is 12 months and it does not roll over to 0 after this value.  Hold down the (+) or (-) button to roll through 
the numbers. 

32.

 

To turn the UV bulb monitor on or off, hold the “CLOCK SET” button and press the “POWER” button while in 
UV bulb life monitor set up mode.  The word “ON” will appear above the digits when the monitor is turned on, and 
will disappear when the monitor is off.  As long as the monitor is “ON”, the number of months displayed will count 
down to “00.”  When it is not “ON,” it will remain at the current value displayed. 

33.

 

Press the “POWER” button again to set the month count in memory. 

34.

 

To turn the cooler back on, press the “POWER” button one more time.  This process is also how you reset the 
month counter once the previous month count has reached “00.” 

HOT BOOSTER MODE

 

Use the HOT BOOSTER mode when you want to get hot water that is heated to the optimal temperature needed for tea, soup, 
coffee and hot chocolate. 

Push the “HOT BOOSTER” button to turn on the hot tank and heat the water to 200°F.  During this time, the words “HOT 
BOOSTER” appear.  It will take anywhere from 1-4 minutes for the HOT BOOSTER to heat the water up to the optimal 
200°F.  When the HOT BOOSTER water is ready, there is an audible 5 second beep and the words “HOT BOOSTER 
WATER READY” will light up for 10 seconds and then go out.  

WARNING:  Water is extremely hot and can cause 

burns or death from scalding.  Children, the disabled and elderly are at highest risk of being scalded.  Use hot water 

faucet with extreme caution.

 

LOCKING THE DISPLAY CONTROLS

 

Use the locking function if you want to keep people altering your settings.  This may be especially important if children will 
have access to the cooler.  To engage the lock, press and hold the (+) and (-) buttons at the same time for 3 seconds.  After 3 
seconds, you will hear a single beep and the word “LOCKED” will be displayed above the cup icon.  Once the lock has been 
engaged, no cooler settings can be changed.  The hot booster will continue to work.  To remove the lock function, press and 
hold the (+) and (-) buttons again for 3 seconds.  After 3 seconds, you will hear a double beep and the word “LOCKED” will 
disappear.  Now the locking function has been turned off and you can use the other buttons to adjust cooler settings as 
needed. 

CONTROL PANEL QUICK REFERENCE

 

 

The “HOT BOOSTER” turns on the hot tank and heats the water to 200°F which is the optimal temperature needed for 
tea, soup, coffee and hot chocolate.  During this time when the water is being heated (usually 1-4 minutes), the words 
“HOT BOOSTER” appear.  When the HOT BOOSTER water is ready, there is an audible 5 second beep and the words 
“HOT BOOSTER WATER READY” will light up for 10 seconds and then go out. 

 

The cup icon flashes when the hot tank element is ON and heating water. 

 

The snowflake icon flashes when the compressor is ON and cooling water. 

 

Use the (+) or (-) button to set the clock, the ENERGY SAVER mode timing, the temperature of hot and cold water, the 
filter life monitor and UV bulb life monitor. 

 

Press “ENERGY SAVER” to turn “ON” the ENERGY SAVER mode.  The words ‘ENERGY SAVER ON” will light 
up.  Press again and the mode is turned ‘OFF.”  The words “ENERGY SAVER ON” will disappear. 

 

Press the (+) and ‘POWER” buttons at the same time to change or reset the filter life monitor gallon count. 

 

Press the “HOT BOOSTER” and “POWER” buttons at the same time to change or reset the UV bulb life monitor. 

 

Press the (+) and (-) at the same time and the other buttons are disabled until this combination is pressed again.  The 
word “LOCKED” is displayed above the cup icon. 

 

 

CLEANING THE OUTER HOUSING

 

1.

 

Press “POWER” to turn off the LCD display, if applicable.  Unplug the water cooler. 

KEEPING YOUR COOLER CLEAN 

Summary of Contents for Aquabar 2

Page 1: ...the LCD display 5 Setting the Clock 6 Setting hot and cold temperature 6 Setting Energy Saver mode 6 Setting filter life monitor 7 Setting UV bulb life monitor 7 Hot booster mode 8 Locking the displa...

Page 2: ...of gallons is programmed through the display panel on the front of the unit which is detailed on page 7 No message will be displayed until the accumulated number of gallons reaches approximately 90 o...

Page 3: ...y by calling customer service at 614 861 1350 Electrical Power Requirements see data plate on base Tri temp models 115v 60 Hz 4 9A 230v 50 Hz 2 5A Duo temp model 115v 60 Hz 1 2A 230v 50 Hz 0 6A CAUTIO...

Page 4: ...functions properly 1 Make sure water is turned off and line is not under pressure 2 Remove door by lifting out drip tray and pressing door latch down forcing the top of the door to lean outward The r...

Page 5: ...are ready to connect it to your water supply NOTE If you have a leak controller installed on the unit the water supply line should be connected directly to it This will shut the water off as close to...

Page 6: ...LAKE 12 Press or button to set the cold water temperature from OFF to COLD about 50 F to COLDER about 45 F to COLDEST about 40 F NOTE Each time the button is pushed the temperature display advances an...

Page 7: ...tank Example END TIME 6 00 AM When the ENERGY SAVER mode is activated the cold tank and the hot tank will turn back ON at 6 00 AM and normal energy consumption will resume cooling the cold tank and he...

Page 8: ...o the cooler To engage the lock press and hold the and buttons at the same time for 3 seconds After 3 seconds you will hear a single beep and the word LOCKED will be displayed above the cup icon Once...

Page 9: ...the reservoir will not drain out 9 In a clean container prepare a solution of 2 teaspoons 10ml of mild dish soap in 2 gallons 8 liters of clean room temperature water 10 Wash the baffle and lids compl...

Page 10: ...refully pour the 2 gallon solution into the reservoir 5 Let the sanitizing solutions sit for 5 minutes no more than 10 minutes Wipe down the exposed inner surface of the reservoir using the solution i...

Page 11: ...e of the metal base before trying to slide it down The front ear has a notch to slide over a raised area in the plastic base see figure 7 TO REMOVE THE FAUCET MANIFOLD The center front panel under the...

Page 12: ...air is required Follow the sequence of steps listed below to avoid damaging the plastic base in the repair process 1 Drain all water from the unit This will make the unit easier to handle 2 Remove the...

Page 13: ...heat or cool the thermostat may be broken Call customer service Water cooler is noisy The water cooler is equipped with a refrigeration system It is normal to hear a refrigerator like vibrating sound...

Page 14: ...ries Low Battery first warning Green Or Red after 3 days beeping max Flashing or Off a 2 flashes On or Off a 2 beeps Dry Examine the sensor hold button until LED light stays solid to stop alarm turn k...

Page 15: ...e the cost of labor required to disconnect and reconnect plumbing and electrical connections or the labor to remove the refrigeration system from the water cooler will be the responsibility of the use...

Page 16: ...OASIS INTERNATIONAL 222 E Campus View Blvd Columbus OH 43235 U S A 1 800 64 OASIS 1 800 646 2747 www OasisCoolers com Printed in China 2010 OASIS International 031666 019 rev B...

Page 17: ...he silicone plug from it as well then place baffle into reservoir 5 Gently place the UV bulb into the hole in the SS lid 6 Thread it in turn clockwise until it is snug You can lift the black float lid...

Page 18: ...hangs up lift it a little higher or let it drop slightly Panel should come free easily 10 Carefully cut zip tie off of bundled wires inside compressor area Don t cut through wire insulation 11 Insert...

Page 19: ...through hole at back of shelf into the reservoir area 17 Connect wire harness The 4 pin housings only connect one way UV bulb install in Aquabar 2 Note For POU2LR model plug unit in and make sure comp...

Page 20: ...installed the black cabinet top will be almost flush with the area around the circuit board Start Fingers OASIS INTERNATIONAL 222 East Campus View Blvd Columbus OH 43235 U S A 1 800 950 3226 www oasis...

Reviews: