background image

OASIS 50 LPH

-New is designed to facilitate wall mounting as well as counter-top purification.

It is easy and convenient to install.

Recommended Site Preparations:

•    Single phase 100-250 V AC, 50-60 Hz. supply not more than 3m away from the point of     

     installation

•    Raw water supply with ½ inch nipple not more than 3m away
•    Drain for reject water not more than 3m away
•    Installation space as per the dimensions of the purifier
•    For proper installation, make sure that the purifier is mounted on a wall surface. Avoid                            
     installation on wooden and metallic stands
•    For optimum inlet pressure, source water tank should be at least 10 ft. above the purifier                             
     installed

5

Installation

Instructions

Summary of Contents for 50 LPH RO

Page 1: ...Instruction Handbook for Installation Operation and Maintenance REVERSE OSMOSIS SYSTEM Removes Dissolved Impurities Retains Essential Minerals Multiple Puri cation Reverse Osmosis Water Puri er...

Page 2: ...Water Puri er will go a long way in serving you with pure and mineral enriched drinking water thus keeping you and your family in good health We assure you that you will be satis ed with its trouble...

Page 3: ...smosis Process 3 6 Water Flow Diagram 4 7 Electrical Circuit Diagram 4 8 Installation Instructions 5 9 Starting up the Puri er 7 10 Recommended Usage of Rejected Water 7 11 Maintenance 7 12 Important...

Page 4: ...Puri cation Capacity of 50 L hr Suitable for attachment to water coolers Push t components for leak proof maintenance free performance Suitable for Puri cation of Brackish Tap Water Municipal Corporat...

Page 5: ...r may ow backwards into the puri er Avoid sharp bends in pipe Do not block the reject water pipe Use Genuine OASIS Spare Parts for optimum performance Do not try to service the puri er on your own Ins...

Page 6: ...from the concentrated end of membrane towards the diluted end Dissolved salts present in water as charged ions get repelled by the RO membrane and are not allowed to pass through Similarly bacteria a...

Page 7: ...OVEMENT WITHOUT NOTICE 1 2 3 4 5 6 7 8 9 10 Sediment Filter GAC Filter CTO Filter Solenoid Valve Booster Pump 150GPD X 2 Ro Membranes 80 GPD X 4 Post Carbon Filter NRV HPS Flow Restrictor SR ITEM DESC...

Page 8: ...oint of installation Raw water supply with inch nipple not more than 3m away Drain for reject water not more than 3m away Installation space as per the dimensions of the puri er For proper installatio...

Page 9: ...tor labeled as WATER IN on the Left side of puri er 6 Connect one end of blue pipe to upper elbow tting connector in REJECT WATER FR and lead the other end to drain 7 Connect the puri ed water pipe to...

Page 10: ...To ensure that the puri er operates at its BEST a routine maintenance must be performed The frequency of the maintenance will greatly depend upon the raw water quality and consumption of puri ed water...

Page 11: ...LPH OASIS 50 LPH Product Generic Name Product Color Body Material Mounting Puri cation Production Rate Max Duty Cycle Filter Cartridge Membrane Type Inlet Water Pressure Temp Min Inlet Water Pressure...