background image

Oasis SmartChem - INSTALLATION AND OPERATION MANUAL 

 

 

 

 

 

 

Page 

19

 of 

22

 

 

6. 

FURTHER INFORMATION 

•  Should power be interrupted for any reason, the controller will resume normal operation when 

power is restored. 
 

•  Degree of protection against moisture: IP33. 

 

•  Store pool chemicals safely, at least 1.8 metres away from all pool equipment. 

 

•  MAX combined rated input load for the JVA socket is 24Vac at 1.2Amps. 

 

•  The pool size and the proximity to the pH & ORP Set Points determines how long (in seconds) 

the pump will actually dose for. 
 

•  The length of time between one dose of acid and the next is approximately 30 minutes. This 

gives the pool water a chance to mix properly and create a true reading before the next dose is 
administered. This helps to ensure that overdosing doesn’t occur. 
 

•  The  pH  dosing  pump  will  inject  the  acid  into  a  spa  for  either  2  or  4  seconds  per  dose.  The 

amount of dosing time will depend on the size of the spa. 
 

•  The pH dosing pump will inject acid into a pool at a time range of between 4 and 50 seconds 

per dose. The amount of dosing time will depend on the size of the pool. The larger the pool, 
the longer the dosing time. 
 

•  On the Home screen of the Oasis Smart App, pH readings will only be  displayed of a value 

between 5.5 to 8.5. If the reading is outside of this range, the App wil display either, <5.5 (check), 
>8.5 (check), or 

–-(check). 

 

•  The Smartchem will be able to read a pH range of 0 (strongly acidic) to 14 (strongly alkaline) 

but  any reading  outside of  the  5.5  to  8.5 range will  only  be  displayed  in  the  Chemical  Setup 
option of the menu. 
 

•  ORP readings on the home screen of the Oasis Smart App will only be displayed where the 

value is between 300 to 800. If the reading is outside of this range, the App wil display either, 
<300 (check), >800 (check), or 

–-(check). 

 

•  The Smartchem will be able to read a ORP range of 0 (little to no Chlorine) to 1000 (possibly 

over chlorinated) but any reading outside of the 300 to 800 range will only be displayed in the 
Chemical Setup option of the menu. 
 

•  In the Chemical Balance window on the home screen of the Oasis Smart App, the status text 

will display whether the pH or the ORP readings are ‘Low’, ‘High’, or ‘Normal’ in comparison to 
the Set Points for both. 
 

•  If for either the pH or ORP levels, ‘---' is displayed, this is indicating a missing/faulty probe or an 

invalid reading. A water sample test is advised at this point. 
 

•  The Sensor & Injection Manifolds suit 50mm pipe, 4 reducing bushes will be required if you are 

installing the manifolds into 40mm pipe 
 

•  If the pool system is to shut down for a lengthy period of time (eg; repairs to the pool surface), 

it is recommended that the pH & ORP probes be removed from the Injection Manifold and be 
stored  appropriately.  This  involves  putting  storage  fluid  (20%  KCI)  into  the  small  bottles  the 
probes came in, putting the probes into the fluid, and screwing the nut to the top of the bottle. 

o

 

If you don’t remove the probes and put the pH & ORP probes into the storage solution, 
the probes may be damaged and they won’t be covered under warranty. 

 

Summary of Contents for SmartChem

Page 1: ......

Page 2: ...2 GENERAL OVERVIEW 3 3 INSTALLATION 4 Mounting 4 Installation Diagram 4 Base Plate 6 Controller Connection 8 App Setup 9 4 ANCILLARY INSTRUCTIONS 13 Maintenance Schedule 13 Probe Cleaning 14 Replacin...

Page 3: ...L CALCIUM HARDNESS 90 300 mg L PHOSPHATE FREE 0 TOTAL DISOLVED SOLIDS Below 1500ppm Always take a sample of your pool water away from the return jets to ensure as accurate reading as possible Always s...

Page 4: ...m will automatically dose Pool acid when it is required to maintain the set pH level The Oasis SmartChem will also maintain the systems ORP by either turning the Chlorinator On or Off or by automatica...

Page 5: ...red if installing into 40mm pipe for the sensors to mount into the centre of the inputs will be drilled out to accommodate the sensor probes A power cable providing power to the Oasis SmartChem from a...

Page 6: ...or a period of time to ensure the glue used to connect the manifolds has had the appropriate time to dry and bond properly to achieve correct pressure rating The Sensor Injection Manifolds suit 50mm p...

Page 7: ...Soak the ends of supply and injection hoses in hot water for 30 seconds to soften them this will make it easier when fitting the tubes to the pump barbs The lid kit has been installed into the bottle...

Page 8: ...piping from the breather port on the lid to outside of the shed or shelter A through shed connection is supplied to prevent a build up of fumes inside the shed shelter ENSURE THAT THE OASIS SMART CON...

Page 9: ...to be utilised through the App go to page 7 Of this guide and you can exit the menu by pressing the Menu button or if you need to reset the Oasis SmartChem unit press Enter and see below for further i...

Page 10: ...first going into the Chemical Setup menu option first Chemical Setup When you go into the Chemical Setup option in the menu you will see this display The first thing that you will need to do is tell t...

Page 11: ...problem with the pump you are changing over the acid bottle tub or if you have run out of Acid The same functionality applies to the ORP Sensor The Offset will allow you to adjust the reading of the p...

Page 12: ...nd count to let you know how much time is left for the priming cycle The following is displayed on the App Home Screen There is only a limited amount of information displayed in regards to the Chemica...

Page 13: ...is displaying CHECK you will need to take a sample of your pool water to your local pool shop and get it tested and add the amount of Acid or Buffer required to get the pH level back to where it needs...

Page 14: ...page 8 of this manual Check all tubes fittings and connections to ensure no leaks Check the squeeze tube in the Peristaltic pump to ensure that it isn t leaking replace if doing so Apply a silicon lu...

Page 15: ...uted on a soft cloth Clean the pH membrane rinse with water and condition in 20 KCl before use In the case of protein contamination use 5 Pepsin in 0 1M HCl solution HINT Calibrate the pH probe regula...

Page 16: ...gently but firmly lift the cover The head cover will come off to expose the squeeze tube and the head The pump head can be pulled out the squeeze tube will come with it and a new squeeze tube can be...

Page 17: ...rectly Clean and or Re calibrate probe or adjust probe Offset as per pg 8 pH Set Point is set to High Adjust pH Set Point to appropriate level 7 2 7 8 Manual Overdosing of Chlorine Shock Treatment Mai...

Page 18: ...ppropriate level 30 50mg L As per above Note The need to run Stabiliser in an outdoor pool may be reduced if your Chlorinator is sufficiently sized to produce enough chlorine to negate the use of Stab...

Page 19: ...Oasis SmartChem INSTALLATION AND OPERATION MANUAL Page 18 of 22...

Page 20: ...c to 14 strongly alkaline but any reading outside of the 5 5 to 8 5 range will only be displayed in the Chemical Setup option of the menu ORP readings on the home screen of the Oasis Smart App will on...

Page 21: ...e interval of time for the added chemicals to properly mix throughout the pool system Continue testing and adding chemicals until the pool system becomes balanced o If you add large quantities of chem...

Page 22: ...breach of a condition or warranty shall be limited to replacing or acquiring the equipment or part thereof where the same has been supplied The maximum liability incurred by the manufacturer shall no...

Page 23: ...subject s Its use is beyond the control of the author contributor publishers and distributors and should not be relied upon without consulting your local Professional for comprehensive advice This gui...

Page 24: ...Oasis SmartChem INSTALLATION AND OPERATION MANUAL Page 23 of 22 9 NOTES...

Page 25: ...eld VIC 3180 Australia T 03 9887 2131 New South Wales Unit 2 10 Boden Road Seven Hills NSW 2147 Australia T 02 9838 0000 Queensland Unit 4 8 Reichert Drive Molendinar QLD 4214 Australia T 07 5679 6821...