background image

 

24 

 

Fitting the unit head 

How to proceed: 
1.

 

Check the O-ring on the unit head for correct fit. 

– 

Clean the O-ring, replace it if it is damaged. 

2.

 

Carefully push the unit head into the casing up to the stop while applying slight pressure. 

– 

While doing so, slightly turn the unit head to ensure that the tenons and the grooves of the 
bayonet closure mesh. 

3.

 

Turn the unit head clockwise up to the stop. 

 

 

VTC0005 

 

 

Cleaning the quartz glass / Replacing the UVC lamp 

Replace the UVC lamp after no more than 8000 operating hours. With constant operation, this 
corresponds approximately to one pond season. This ensures optimum filtering performance. 

 

 CAUTION 

The quartz glass and UVC lamp could break and cause cuts. 

 

Act with caution when performing work on the UVC clarifier in order to avoid cuts. 

 

Avoid shocks, impacts and abrupt movements to prevent the glass from breaking. 

 

Prerequisite 

 

The unit head is removed. (

Dismantling the unit head) 

 

Only use UVC lamps, the identification and power data of which correspond to the information 
on the type plate. (

Technical data) 

 

Downloaded from www.watergardeningdirect.com

Summary of Contents for Vitronic 11 W

Page 1: ...Vitronic 11 W 18 W 24 W 36 W 55 W Operating instructions Downloaded from www watergardeningdirect com...

Page 2: ...o electrical installation in outdoor areas Only allow a qualified elec trician to perform the electrical installation The qualified electrician has the required professional training knowledge and ski...

Page 3: ...ds For operation with clean water Operate the product in compliance with the technical data Technical data The following restrictions apply to the unit This product is not suitable for general lightin...

Page 4: ...1 1 2 Casing 1 1 3 Transparent stepped hose adapter with O ring For hose diameter 19 38 mm 2 4 Transparent stepped hose adapter with union nut and flat seal For hose diameter 25 38 mm 2 5 UVC lamp Vit...

Page 5: ...it from freezing temperatures Do not dispose of the unit with normal household waste Read the operating instructions Installation and connection Vitronic 11 W It is not necessary to remove the unit he...

Page 6: ...t at least 2 m from the edge of the pond Only install the unit in the permitted positions This ensures fault free operation Allow sufficient space for carrying out maintenance work VTC0016 VTC0006 Dow...

Page 7: ...ped hose adapter Screw the stepped hose adapter with the flat seal or O ring onto the connection so that the connection is leak tight You can choose from the two connections arranged opposite each oth...

Page 8: ...the two holes in the container wall of the flow through filter 3 Screw the inlet nozzle with the O ring onto the outlet socket and hand tighten the inlet noz zle 4 Connect the supply hose to the inle...

Page 9: ...itched on The UV light shines through the closing cap when the UV lamp is switched on VTC0010 Maintenance and cleaning NOTE Do not use aggressive cleaning agents or chemical solutions These agents can...

Page 10: ...UVC clarifier in order to avoid cuts Avoid shocks impacts and abrupt movements to prevent the glass from breaking For safety reasons the UVC lamp can only be turned on when the UVC clarifier is proper...

Page 11: ...lamp Replace the UVC lamp after no more than 8000 operating hours With constant operation this corresponds approximately to one pond season This ensures optimum filtering performance CAUTION The quart...

Page 12: ...ure that the O ring is located in the gap between the unit head and the quartz glass Tighten the clamping screw up to the stop Wipe the quartz glass with a damp cloth to remove dirt and fingerprints V...

Page 13: ...again once it has cooled down Technical data Description Vitronic 11 W 18 W 24 W 36 W 55 W Connection voltage V AC 220 240 220 240 220 240 220 240 220 240 Mains frequency Hz 50 60 50 60 50 60 50 60 5...

Page 14: ...t content 0 4 0 4 Overall dry residue mg l 50 50 Temperature C 4 35 4 30 Wear parts UVC lamp quartz glass and O ring for quartz glass Disposal NOTE Do not dispose of this unit with household waste Dis...

Page 15: ...291 VTC0014 Downloaded from www watergardeningdirect com...

Page 16: ...292 VTC0012 Downloaded from www watergardeningdirect com...

Page 17: ...293 VTC0013 Downloaded from www watergardeningdirect com...

Page 18: ...OASE GmbH Tecklenburger Stra e 161 48477 H rstel Germany 49 0 5454 80 0 49 0 5454 80 9353 info oase com 88469 09 21 Downloaded from www watergardeningdirect com...

Reviews: