Product Description
A
Varionaut 150 24V/DMX/02
1
DMX box
•
DMX bus connection
2
Pump
3
Filter housing
4
Stand
5
PowerBox 24 V DC
•
Power supply connection
Varionaut 150 24V/DMX/02 is a pump controlled via the DMX/RDM bus.
•
Water-tight plug-in cabling of the DMX/RDM bus via the DMX box. This makes it easier to connect the DMX controller
and other DMX-compatible consumers.
•
A DMX controller or DMX/RDM controller from OASE is used for controlling the unit.
– The DMX controller is not included in the scope of delivery. The application and extent of the system determine
the requirements for the DMX controller.
Intended use
Varionaut 150 24V/DMX/02, referred to as "unit", may only be used as specified in the following:
•
For use in fountain systems.
•
Operate in accordance with instructions. (→ Technical data)
•
Operation under observance of the permissible water quality. (
→
Water quality)
The following restrictions apply to the unit:
•
Do not use in swimming ponds.
•
Never use the unit to convey fluids other than water.
•
Never run the unit without water.
•
Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.
•
Do not connect to the domestic water supply.
Installation
B
W A R N I N G
Dangerous electrical voltage.
Possible consequences:
Death or severe injuries caused by electric shock from electrical units operated in
or near water.
Protective measures for accessible ponds:
•
Only use electrical units or installations with a rated voltage of U
AC
≤
12 V or U
DC
≤
30 V in the water.
•
Electrical installations with a rated voltage of U
AC
> 12 V or U
DC
> 30 V must be located at a distance of at
least 2 m from the water.
Protective measures for non-accessible ponds:
•
Electrical installations with a rated voltage of U
AC
> 12 V or U
DC
> 30 V must be located at a distance of at
least 2 m from the water.
Submerged installation of the pump
•
Do not suspend the pump from the suction socket or pressure socket.
– The pump housing may be damaged.
•
Only operate the pump with the filter basket fitted.
How to proceed:
C
1. Place the pump with stand in a horizontal position on a suitable base and bolt down.
– Ensure that the pump is fully submerged in the water.
2. Screw the reducing socket onto the pump outlet.
3. Screw the nozzle (e.g. Komet 10-14 T) onto the reducing socket.