![background image](http://html1.mh-extra.com/html/oase/promax-30000/promax-30000_operating-instructions-manual_3491199011.webp)
11
- GB -
Malfunction
Malfunction Cause
Remedy
Pump does not start
No mains voltage
Check mains voltage
Clean/check supply lines
Pump does not deliver
Filter housing clogged
Clean strainer casings
Reduce hose length to the necessary minimum,
do not use unnecessary connection parts
Insufficient delivered quantity
Filter housing clogged
Excessive loss in the supply lines
Clean strainer casings
Reduce hose length to the necessary minimum,
do not use unnecessary connection parts
Pump switches off after a short running time
Excessively soiled water
Water temperature too high
Clean pump
Note maximum water temperature of +35°C
Manual transmitter reach fades
Batteries too weak
Replace batteries
Manual transmitter reach fluctuates
Interferences through other units
Receiver positioned unfavourably
Switch off other units which could interfere
(mobile phone, remote thermometer, remote
baby-sitter, ...)
Find a new position for the receiver housing. If
necessary, increase the distance to the floor
Manual transmitter without function
Batteries discharged or incorrectly inserted
Manual transmitter not taught-in
Receiver was reset
Check functions
Teach-in manual transmitter
Teach-in manual transmitter again
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
Disposal of batteries
Do not dispose of batteries with the household waste. Only dispose of dead batteries by using the return system
provided for this purpose.
Disposal of batteries within the European Union
As a user, you are obligated by law to return used batteries. Return is free of charge.
Either dispose of batteries through the public return and recycling systems of your municipality or community, or return
the batteries to the place where they were bought.
Batteries containing harmful substances bear the following signs:
Pb = Battery contains lead
Cd = Battery contains cadmium
Hg = Battery contains mercury
Li = Battery contains lithium
Storage/Over-wintering
The unit is frost resistant to minus 20 °C. Should you store the unit outside of the pond, clean it thoroughly with a soft
brush and water, check it for damage, then store immersed in water or filled with water. Do not immerse the power plug
in water!
For temperatures below zero, the pump is heated when deactivated so that it does not freeze. This function is indicated
by a green flashing light on the receiver.
Important!
To ensure this function, leave the plug of the cable in the socket and do not pull it out or disconnect it.
Repair
A damaged housing cannot be repaired and must be put out of operation. Dispose of the unit in accordance with the
regulations.
Summary of Contents for promax 30000
Page 1: ...14440 03 F Promax 20000 30000 14440 GAW Aquamax Promax A6_end 22 03 10 12 40 Seite 2...
Page 3: ...3...
Page 77: ...77 BG OASE Living Water Promax 20000 30000 Promax 20000 30000 2 OASE 16 BG...
Page 78: ...78 BG 30 mA H05RN F DIN VDE 0620 OASE 2 2...
Page 79: ...79 BG 1 80 1 3 1 3 10 3 5 1 0 1 2 0 2 0 0 23 B 2 8 3 1 2 10 8 3 6 12 5 11...
Page 80: ...80 BG 35 C Pb Cd Hg Li 20 C...
Page 81: ...81 UA OASE Living Water Promax 20000 30000 Promax 20000 30000 OASE 16 UA...
Page 82: ...82 UA 30 H05 RN F DIN VDE 0620 OASE 2...
Page 83: ...83 UA 1 80 1 3 1 3 10 3 5 1 0 1 I 2 0 2 I 0 I 0 I 23 B 2 8 3 1 2 10 8 3 6 12 5 11...
Page 84: ...84 UA 35 C Pb Cd Hg Li 20 C...
Page 85: ...85 RU OASE Living Water Promax 20000 30000 Promax 20000 30000 2 OASE 16 RU...
Page 86: ...86 RU 30 H05RN F DIN VDE 0620 OASE 2 2...
Page 87: ...87 RU 1 80 1 1 3 3 10 3 5 1 0 1 I 2 0 2 I 0 I 0 I 23 B 2 8 3 1 2 10 8 3 6 12 5 11...
Page 88: ...88 RU 35 C Pb Cd Hg Li 20 C...
Page 89: ...89 CN OASE Living Water Promax 20000 30000 Promax 20000 30000 OASE 16 CN...
Page 90: ...90 CN 30 H05RN F DIN VDE 0620 2 2...
Page 91: ...91 CN C 1 80 1 C 3 1 3 10 C 3 5 1 0 1 I 2 0 2 I 0 I 0 I 23A B 2 8 3 2 1 10 8 3 5 11 6 12...
Page 92: ...92 CN 35 C Pb Cd Hg Li 20 C...
Page 97: ...15311 08F...