- GB -
18
Remedy of faults
Malfunction Cause
Remedy
No spotlight is lit.
No supply voltage
Check all cables and connections.
The luminous intensity of all spotlight LEDs is
0 %.
−
Change the spotlight setting.
−
Check the luminous intensity of the LEDs
and the DMX address.
Underwater LED driver, DMX controller or swit-
ching power pack defective
Determine which unit is defective and proceed
with the malfunction remedy according to its in-
struction manual.
One spotlight is not lit.
Spotlight not connected.
Check connection between spotlight and LED
driver.
The luminous intensity of all spotlight LEDs is
0 %.
−
Change the spotlight setting.
−
Check the luminous intensity of the LEDs
and the DMX address.
Spotlight or underwater LED driver output de-
fective
−
Connect the spotlight to a different output on
the underwater LED driver.
−
Have spotlight repaired.
−
Have underwater LED driver repaired.
Underwater LED Driver /DMX/02 is not compa-
tible with the spotlight.
Use underwater LED driver /DMX/02, ver-
sion 2.0. The following spotlights are only com-
patible with version 2.0:
−
ProfiLux LED 110/DMX/02 (56267)
−
ProfiPlane LED 110/DMX/02 (56298)
−
ProfiLux LED Spot 1500/DMX/02 (56388)
−
ProfiLux LED Flood 1500/DMX/02 (56391)
An individual spotlight does not light up in the
desired colour.
Incorrect spotlight setting
−
Change the spotlight setting.
−
Check the values for the LEDs, DMX add-
ress and configuration mode.
LED of the spotlight defective
Have spotlight repaired.
Luminous intensity of a spotlight is insufficient.
Spotlight LEDs excessively dimmed
−
Change the spotlight setting.
−
Check the values for the LEDs, DMX add-
ress and configuration mode.
The luminous intensity has been automatically
reduced due to excessive temperature in the
spotlight.
No measure required.
Spotlight glass soiled
Clean spotlight glass.
Repair
The unit can only be repaired by
OASE
. Please send the unit to your
OASE
dealer.
Maintenance and cleaning
Cleaning the unit
•
Clean all components with clean water and a soft brush.
•
Never clean the device using a pressure washer.
Unit maintenance
The unit requires regular maintenance. Carry out the work according to the maintenance schedule.
•
Only allow the maintenance work to be carried out by trained personnel who are qualified for these activities due to
their technical training, knowledge and experience.
Storage/Over-wintering
Observe the permissible operating temperature range. (
→
Technical data)
•
If the limit values are exceeded or gone below, it is necessary to remove the unit. Clean the unit thoroughly and
check it for damage.
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
37744_04-14_GA_ProfiLED_110_320_18 18