- EN -
57
4.3.5 Connecting the dirt outlet
The water in the container can be drained via the DN 75 dirt outlet with slide valve at the bottom of the
container if required (for cleaning, repair, overwintering).
►
Connect a suitable DN 75 pipe and drain the dirty water into the sewer system.
How to proceed:
K
1. Remove the cap nuts and push the dirt outlet onto the connection.
2. Tighten the hose clip.
3. Tighten the cap nuts.
Connect the DN 75 pipe to the DN 110 pipe for the coarse dirt, and drain the dirty water via a DN 110
pipe into the sewer system. This will ensure that the dirty water pipe will be conveniently flushed out with
sufficient pressure.
4.4
Connecting the control system with EGC box
4.4.1 Connecting the control system
For the pump fed system and for the gravity fed system, the cable harness contains the connection cables
of the signal box, drum motor and rinsing pump. These connection cables have to be connected, the EGC
box is already connected.
L
►
Connect the three connectors of the cable harness to the control system sockets. Hand-tighten the
union nuts.
– The connections are designed to prevent misconnection.
– First flood the container with water, then connect the control system to the mains voltage/power
supply.
4.4.2 Connecting the EGC box
Integration of the filter system into the EGC
network is optional and not necessary for operation. (→
Garden Control System (EGC))
The Connection Cable EGC cable is required for connecting the EGC box.
The correct fastening of the plug connector is important for a secure connection and an interference-free
EGC network.
How to proceed:
N, O
1. Remove the protection cap from the unit.
2. Fit the plug connector and secure with the two screws (max. 2.0 Nm).
– Ensure that the rubber seal is clean and fits exactly.
– Replace the rubber seal if damaged.
3. Remove the protection cap from EGC-OUT of the last unit in the EGC network, fit the terminal resistor
EGC and secure it with the two screws (max. 2.0 Nm).
– Ensure that on EGC-OUT of the last unit in the EGC network, the terminal resistor EGC is installed
instead of an EGC connection cable, to ensure that the EGC network is closed off properly.
– The scope of delivery of InScenio FM-Master WLAN or InScenio EGC Controller each contains a
terminal resistor EGC.
Downloaded from www.watergardeningdirect.com
Summary of Contents for ProfiClear Premium Compact-L EGC
Page 1: ...ProfiClear Premium Compact L Downloaded from www watergardeningdirect com...
Page 2: ...2 A ProfiClear0126 Downloaded from www watergardeningdirect com...
Page 4: ...4 E ProfiClear0127 Downloaded from www watergardeningdirect com...
Page 5: ...5 F ProfiClear0128 G ProfiClear0164 Downloaded from www watergardeningdirect com...
Page 6: ...6 H ProfiClear0129 I ProfiClear0130 Downloaded from www watergardeningdirect com...
Page 8: ...8 M ProfiClear0133 N FMR0031 O EGC0003 Downloaded from www watergardeningdirect com...
Page 46: ...51990 03 18 Downloaded from www watergardeningdirect com...