- EN -
56
Gravity fed system
B, J
The filter system has three inlets DN 110. If necessary, the connection set (19005) can be used to install
a fourth inlet DN 110. In this case, the maximum flow rate of the filter system increases to 33000 l/h.
►
Markings for the through holes of the fourth inlet are provided on the container wall. Ensure that the
through hole is cut out.
►
Recommendation: Limit the flow rate to 8500 l/h per DN 110 inlet.
►
Use suitable DN 110 pipes for connecting the bottom outlet and/or skimmer and the inlet.
►
Secure the pipes so that fish cannot swim into them.
4.3.3 Fitting the UVC clarifier
Pump fed system
The Bitron UVC clarifier is fitted to the filter container. The maximum flow rate of the filter system remains
20000 l/h.
►
It is necessary to remove a screen element to access the sealing plugs.
(→
►
A filter pump is connected to the UVC clarifier for operation with two filter pumps. The other filter pump
is connected to the 50 mm (2 ") inlet.
(→
A non-return valve is installed in the connection for the filter pump to prevent water from returning. If a
filter pump each is to be connected to the Bitron and to the connection for the filter pump, the pump on
the connection for the filter pump can be switched on/off as required without any problems.
How to proceed:
I
1. Undo the screws with a screwdriver and remove the sealing plugs.
2. Guide the outlet sockets of the Bitron with flat seals through the holes in the container wall.
3. Screw the adapters onto the outlet sockets and hand-tighten.
4. Screw the 30° inlet bends with cap nuts onto the adapters and hand-tighten.
– Position the inlet bends so that they are pointing downwards.
– Correctly positioned inlet bends prevent unintended overflow (emptying of the pond) and also serve
to reduce noise emissions.
5. Connect the Bitron to the filter pump in accordance with the operating manual.
Gravity fed system
The Bitron Gravity UVC clarifier is fitted in the Individual Module. (
→
Please refer to the "Bitron Gravity"
and "ProfiClear Premium Individual Module" operating manuals.)
4.3.4 Connecting the coarse dirt outlet
J
The coarse dirt that collects in the dirt channel drains away via the DN 110 coarse dirt outlet (top outlet
on the container) on the input side.
►
Connect a suitable DN 110 pipe and drain the dirty water into the sewer system.
Downloaded from www.watergardeningdirect.com
Summary of Contents for ProfiClear Premium Compact-L EGC
Page 1: ...ProfiClear Premium Compact L Downloaded from www watergardeningdirect com...
Page 2: ...2 A ProfiClear0126 Downloaded from www watergardeningdirect com...
Page 4: ...4 E ProfiClear0127 Downloaded from www watergardeningdirect com...
Page 5: ...5 F ProfiClear0128 G ProfiClear0164 Downloaded from www watergardeningdirect com...
Page 6: ...6 H ProfiClear0129 I ProfiClear0130 Downloaded from www watergardeningdirect com...
Page 8: ...8 M ProfiClear0133 N FMR0031 O EGC0003 Downloaded from www watergardeningdirect com...
Page 46: ...51990 03 18 Downloaded from www watergardeningdirect com...