Correct electrical installation
−
Electrical installations must meet the national regulations and may only be carried out by a qualified electrician.
−
A person is regarded as a qualified electrician, if, due to his/her vocational education, knowledge and experience, he
or she is capable of and authorised to judge and carry out the work commissioned to him/her. This also includes the
recognition of possible hazards and the adherence to the pertinent regional and national standards, rules and regu-
lations.
−
For your own safety, please consult a qualified electrician.
−
The unit may only be connected when the electrical data of the unit and the power supply coincide. The unit data is
to be found on the unit type plate or on the packaging, or in this manual.
−
Ensure that the unit is fused for a rated fault current of max. 30 mA by means of a fault current protection device.
−
Extension cables and power distributors (e. g. outlet strips) must be suitable for outdoor use.
−
Ensure that the power connection cable cross section is not smaller than that of the rubber sheath with the identifi-
cation H05RN-F. Extension cables must meet DIN VDE 0620.
−
Protect the plug connections from moisture.
−
Only plug the unit into a correctly fitted socket.
Safe operation
−
Never operate the unit if either the electrical cables or the housing are defective!
−
Do not carry or pull the unit by its electrical cable.
−
Route cords/hoses/lines in a way that they are protected against damage, and ensure that they do not present a
tripping obstacle.
−
Only open the unit housing or its attendant components, when this is explicitly required in the operating instructions.
−
Only execute work on the unit that is described in this manual. If problems cannot be overcome, please contact an
authorised customer service point or, when in doubt, the manufacturer.
−
Only use original spare parts and accessories for the unit.
−
Never carry out technical modifications to the unit.
−
The power connection cables cannot be replaced. When the cable is damaged, the unit or the component needs to
be disposed of.
−
Only operate the unit if no persons are in the water!
−
Keep the socket and power plug dry.
Important! The unit is equipped with a permanent magnet. The magnetic field may affect the function of pace-
makers.
Installation
The unit can be placed submerged or dry.
Always place the unit below water level.
Place the unit horizontally on the ground ensuring its stable position.
Connect the unit
Figure B
Recommendation for the use of the stepped hose adapter and hose connector:
AquaMax Eco Premium 4000/6000:
−
Second inlet (1): Stepped hose adapter 25 to 38 mm (1 to 1½ ")
−
Pump outlet (2): Hose connector 38 mm (1½ ") (alternative: stepped hose adapter 25 to 38 mm (1 to 1½ "))
AquaMax Eco Premium 8000/10000/12000/16000/20000:
−
Second inlet (1): Stepped hose adapter 25 to 38 mm (1 to 1½ ")
−
Pump outlet (2): Hose connector 50 mm (2 ") (alternative: stepped hose adapter 25 to 38 mm (1 to 1½ "))
Push the hose clip and the union nut over the hose. Fit the hose on the stepped hose adapter or hose connector and
secure with the hose clip.
Fit the stepped hose adapter or hose connector on the second inlet (1) or pump outlet (2) and hand-tighten the union
nut.
22265_06-13_GA_Aquamax Eco Premi11 11
01.07.2013 10:48:50
Summary of Contents for AquaMax Eco Premium4000
Page 2: ...2 22265_06 13_GA_Aquamax Eco Premi2 2 01 07 2013 10 48 48...
Page 3: ...3 22265_06 13_GA_Aquamax Eco Premi3 3 01 07 2013 10 48 49...
Page 4: ...4 22265_06 13_GA_Aquamax Eco Premi4 4 01 07 2013 10 48 50...
Page 12: ...117 22265_06 13_GA_Aquamax Eco Premi117 117 01 07 2013 10 48 54...
Page 13: ...118 22265_06 13_GA_Aquamax Eco Premi118 118 01 07 2013 10 48 54...
Page 14: ...119 22265_06 13_GA_Aquamax Eco Premi119 119 01 07 2013 10 48 55...
Page 15: ...22265 06 13 22265_06 13_GA_Aquamax Eco Premi120 120 01 07 2013 10 48 55...