Commissioning/start-up
NOTE
Prevent the pump from running dry. Otherwise the pump will be destroyed.
Only operate the pump when it is submerged or flooded.
Switching ON/OFF
•
Switching on: Plug the power plug into the outlet.
–
The unit
switches on immediately.
•
Switching off: Pull the power plug from the outlet.
Environmental Function Control (EFC)
When started up, the pump automatically performs a pre-programmed self-test
(Environmental Function Control (EFC)). The pump detects if it is running dry / blocked or
submerged. The pump shuts down automatically after 60 to 120 seconds if it runs dry/is
blocked. In the event of a malfunction, disconnect the power supply and “flood the pump”
or remove the obstacle. Afterwards, the unit can be restarted.