- GB -
14
Installation
Installing the unit
C, D
The unit can be submerged in water or set up in a dry location, but must always be protected from direct sunlight.
Options:
−
Fasten the unit to a suitable base using 4 screws (not included in the scope of delivery).
−
Fasten the PowerBox 24V DC to a suitable foundation using 2 screws.
−
Fasten the DMX box to a suitable foundation using 2 screws.
Connecting the unit to a DMX control unit
E
•
Remove the screws from the DMX box and take off the two cover caps.
•
Check both ends of the DMX cable: Are the seals in place and undamaged? Replace the seals if necessary.
•
Insert the plug of the DMX cable into the socket for the DMX input signal (WECS). Plug the cable bushing into the
unit. Use two screws each to secure the connection. Ensure correct seating of the seal in the connector!
Connecting additional units to the DMX controller (WECS)
•
Provide additional DMX cables and check before use: Are the seals in place in the cable connectors and are they
clean and undamaged? Replace the seals if necessary.
•
Remove the two screws and take off the cover cap.
•
Insert the connector of the DMX cable into the socket of the already connected unit for the DMX output signal (DMX-
OUT) and secure with the two screws. Insert the other connector of this DMX cable into the socket for the DMX in-
put signal (DMX-IN) of the next unit. Ensure correct seating of the seal in the connector!
•
Ensure that a terminator is plugged into the the last unit of the DMX connection chain.
The maximum number of additional units depends on the number of DMX channels required by the unit to be connec-
ted, and the addresses that are to be assigned to these channels.
Connecting the unit to the power supply
E
•
Provide the connection cable for connecting the switching power pack and the PowerBox 24V DC.
−
Check both connectors of the connection cable: Are the seals in place in the connectors of the connection cable
and are they undamaged? Replace the seals if necessary.
•
Remove the two screws from the connection terminal and the PowerBox 24V DC and take off the cover cap.
•
Connect the switching power pack and the PowerBox 24V DC to each other by means of the connection line.
•
Secure each connecting plug with two screws and tighten the screws until they are hand-tight (max. 2 Nm).
30539-10-13_GA_Underwater Switch14 14
29.10.2013 10:16:30
Summary of Contents for 56411
Page 2: ... 2 A UWR0001 B UWR0004 30539 10 13_GA_Underwater Switch2 2 29 10 2013 10 16 30 ...
Page 3: ... 3 C D UWR0002 UWR0003 E PLX0004 30539 10 13_GA_Underwater Switch3 3 29 10 2013 10 16 30 ...
Page 37: ...37 UWR0006 30539 10 13_GA_Underwater Switch37 37 29 10 2013 10 16 31 ...
Page 38: ...30539 10 13_GA_Underwater Switch38 38 29 10 2013 10 16 31 ...