background image

Introduction and Warnings

2

This equipment is part of a large range of traffic flow products. They are designed to be easy to install, as 
all settings and internal wiring have been completed in our factory. Any of the instructions in this manual 
should only be carried out by a qualified service engineer or a competent person.

The turnstiles are ready to bolt down, connect to a single phase power supply and have any access 
control wired into them (Please note that advice should be sought on wiring instructions). The steps must 
be completed before the power is turned on to prevent accidents.

The following information is a guide only, and whilst we have made every effort to be accurate and correct 
there may be errors which we cannot be held responsible for.

With a correct installation you can expect to enjoy many years of reliable service from this product, we do 
however recommend that the product has a bi-annual service carried out by a qualified engineer. Please 
contact our service department to obtain a quote. As we manufacture the products we are best suited to 
care for your equipment. 

Thank you for your custom and welcome to the exciting world of Total Traffic Flow Solutions.

/

    

/

20

!

Important Safety Notice

Automatic turnstiles are designed to Control the flow of human 
traffic only. It can be dangerous to allow the passage of  any 
other self-powered animal or device to utilise this method of 
access without appropriate warnings and or signage.
It may be necessary for the end user of this product to provide 
an alternative, safe method of access to cater for the previously 
mentioned categories.
The end user should fit all necessary signage and warning 
notices to either side of the turnstile, which should be visible and 
clear from all directions of approach.
The product that was shipped to you was designed with a control 
program to protect all categories from harm or affect this 
however is only a precaution. It should not be modified or 
tampered with by any unauthorised person not sanctioned by the 
manufacturer.

Please sign and date below to say that you have read and 
understood this notice before ANY installation work:

 The “Warnings” leaflet and “Instruction booklet” supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
 Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
 Keep the instructions together with the technical brochure for future
reference.
 This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
 The Company declines all responsibility for any consequences resulting
from improper use of the product, or use which is different from that
expected and specified in the present documentation.
 Do not install the product in explosive atmosphere.
 The construction components of this product must comply with the
following European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC
and subsequent amendments. As for all non-EEC countries, the abovementioned
standards as well as the current national standards should
be respected in order to achieve a good safety level.

Information on using
this manual

Ÿ

Read all information thoroughly

Ÿ

Pay attention to all safety advice

Ÿ

Be aware of the symbols (shown above right and above 

left)  as  they  have  different  meanings.  One  is  an 
information symbol, the other a warning.

Ÿ

There are many artists impressions of the product in this 

manual you should refer to the images as a guide only. 

Professional  CAD

  drawings  should  be  used  as  a 

reference drawing and nothing else. As before every 
effort  has  been  made  to  be  100%  accurate  in  this 
manual but we cannot make any guarantees.

Ÿ

As we constantly innovate our products we may change 

the quoted spec and any other details that have been 
documented in this manual so you should always refer 
to the supplier to see if the manual that was shipped 
with your product is the latest edition.

Ÿ

As  with  all  electrical  installations  you  should  use  a 

qualified electrician and obey all of the latest laws and 
regulations.

Ÿ

Be sure to fill out and complete 

ALL

 paperwork where 

instructed as this manual is the equipments log book 
and maintenance manual.

The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing
closing structures (door, gates etc.), as well as from any deformation
which might occur during use.
 The installation must comply with the provisions set out by the following
European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and
subsequent amendments.
 Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
 Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3mm.
 Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
 Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
 Fit all the safety devices (photocells, electric edges etc.) which are
needed to protect the area from any danger caused by squashing,
conveying and shearing, according to and in compliance with the
applicable directives and technical standards.

PF4000FH

Summary of Contents for PF4000FH

Page 1: ...PF4000FH PF4000FH Automatic Full height Turnstile Single or Double Duty Cycle 100 GB O M Manual Revision 4 1...

Page 2: ...mentation Any other use not specified in this documentation could damage the product and be dangerous The Company declines all responsibility for any consequences resulting from improper use of the pr...

Page 3: ...ising from the movement of goods from supplier through haulier to the recipient and end user including any home deliveries The project will focus upon the delivery and collection of goods and the haza...

Page 4: ...M12 bolts see below Now move on to step 5 The numbers in the text document below relate to the drawings below 3 1 2 4 45 mins Component Identification and Notes You should check that you have receive...

Page 5: ...andard and if not required should be made clear at the point of order 9 Now connect all power and access control using the wiring diagram on page 8 For any other specific wiring access control wiring...

Page 6: ...rconnecting parts should be checked for tightness and security 7 Any defects or failure in the coating of the turnstile should be noted and reported immediately to the seller or manufacturing company...

Page 7: ...as you may risk wiping the memory 10 Press menu ok button Green Button 11 When downloaded TRANSFER OK STOP LD will be displayed 12 Press menu ok button 13 Scroll up to run stop flashing 14 Press menu...

Page 8: ...8 Wiring Diagram Illustration PF4000FH...

Page 9: ...9 Wiring Diagram Schematic PF4000FH...

Page 10: ...VICES OPERATING THROUGH EXTERNAL SOURCES MUST NOT BE RECEIVED FROM THE PLC INSIDE THE TURNSTILE POSOTIVE 24VDC INPUT NEGATIVE 24VDC INPUT I1 LOCK I2 ENTRY SIGNAL I3 EXIT SIGNAL I4 ENTRY LIMIT IB EXIT...

Page 11: ...ations can vary depending on model spec Limit Switches Solenoid Header Shaft Limit Striker Solenoid Paddle Lever Adjusting Cams Ratchet Cog Paddle Levers Solenoid Solenoid Paddle Levers Paddle Levers...

Page 12: ...ile arm using the PLC first make sure the screen says RUN LD if it does not follow the troubleshooting guide on page 11 when the screen says RUN LD follow below 3 4 To make the Turnstile move upwards...

Page 13: ...mally Open Q2 1 24v Common Q2 2 Exit Solenoid Active to close Turnstile Q3 Normally Open Spare Spare Not Used Q4 Normally Open Spare Spare Not Used The table bottom relates to the diagram directly bel...

Page 14: ...Cable of direction sensor may be displaced from connector on the electronic card 3 One of the direction sensors may be broken down 1 Broken cables if any are soldered The unit is cleaned from the dus...

Page 15: ...in 2 Microcontroller and ULN 2803A circuit or electronic board is replaced with a new one After passage is done arms do not finalise the movement and do not settle to their place 1 Balance arm spring...

Page 16: ...in accordance with the following documents Document Ref Revision Description Pf4000 O M 3 0 System guides and drawings as defined within O M Manuals Part 4 The following test schedules refer Test Sche...

Page 17: ...ons undertaken Product works the way site need it to this includes no passage time out etc System has had the completed conformity certificate All items on the delivery note have been handed over to c...

Page 18: ...w at any point service repair work is carried out on the product This is to achieve two things 1 To keep a history of the product for yourself and your supplier manufacturer 2 To keep an accurate log...

Page 19: ...ectromagnetic Compatibility Directive 89 336 CEE And is in conformity with the following standards other specifications EN292 1 1991 Machinery basis terminology methodology EN292 2 machinery technical...

Page 20: ...Made in the UK Proudly Made in the UK PF4000FH Accessories Specification Power Requirement Arms and body Duty Cycle Flow Rate Key Points Access Controls 220v Single Phase 50Hz 5 Amps Primed Powder Co...

Reviews: