background image

TO SET-UP THE TABLE: 

Place the folded table sitting on 

the rubber bumpers. With the 

heel of your hand, bump the 

UniLock™ tab between the face 

rest outlets and the table will 

open. Open the table up until 

the legs are fully extended.   

  TABLE SET UP

When the table is fully opened, use your foot as a 
brace on one of the leg extensions. Using the handle, tilt 
the table upright until all four feet are on the floor. 
Lift one end of the table, press down on the middle and 
tension the cables a little. 

TO CHANGE THE TABLE HEIGHT: 

FOOT PUMP & HAND VALVE PLACEMENT: 

page 1    www.oakworks.com

UniLock™

Check for and 

remove any kinks  

in the tubing system.

Place the foot pump on the floor 
below the table but within easy 
reach of your foot. Run the tube 
to the hand control through the 
table handle to insure it is easy 
to reach. 

CAUTION

: Make sure the cables are slightly  

 

 

tensioned before getting on the table.

When the table is set up, the 

height should be adjusted to 

the proper working height 

for the therapist. Once this 

is determined, adjust the legs 

accordingly. Choose the hole 

that represents the desired 

height. After removing the 

knob, put the bolt through 

that hole. Replace and tighten  

the knob by hand until snug. 

Repeat on all other leg exten-

sions, setting all extensions 

at same height. 

SHIATSU CABLES

1. With the table on its side,  
  remove the wing nut from  
  the bolt and remove long  
  brace, cable and washers  
  from the short brace.  
  Reassemble them without  
  the cable. Repeat on the  
  second wing nut.

2. Turn the Unilock™ clasp to  
  the side. 

3. Fold the legs against the  
  underside and lay the table  
  down flat on the floor.  

CAUTION:

 

Shiatsu Cables must 

be installed as shown when using 

table in normal height ranges. 

Reviews: