When moving the table, place one person at each corner of the table. Have each person firmly grasp the 

table top. When moving any piece of heavy equipment, bend at the knee and lift with your legs and not with 

your back. Be aware and use proper, safe procedures for moving a table of this size to prevent injury to 

yourself or damage to the table. We strongly recommend that a flatbed dolly that can hold the entire table 

be used if moving the table involves any large distance.

CAUTION

MOVING THE TABLE

Before moving the table, disconnect the power cord from the power outlet. Secure the power cord 

and all hand or foot controls before moving. The table weighs as much as 190 lbs. (86 kg.) Four 

people are required to move the table safely. Do not use the table to transport a client.

DIRECTIONS FOR USE

Position at low height

TABLE LEVELING INSTRUCTIONS

1.  Place the table in the location where you plan to use it. 
2.  Rock the table to determine if it is level with the floor. If 

the table rocks back and forth at all, the foot that clears 

the floor when you rock the table will need adjustment. 

3.  Adjust the Leveler Foot by first loosening the locking 

nut found just above the rubber Leveler Foot with the 

1/2” open-end wrench. 

4.  Lower the adjustable rubber Leveler Foot until it meets 

the floor snugly. Tighten the locking nut against the leg 

of the table with the 1/2” open-end wrench to fix the 

Leveler Foot in position. 

5.  Rock the table again to be sure adjustments have  

stabilized the table. If necessary make any additional 

adjustments in the same way.

11

Summary of Contents for Clinician Premiere

Page 1: ...OAKWORKS Clinician Premiere USER MANUAL www oakworks com 717 235 6807...

Page 2: ...within this document is subject to change without notice and should not be construed as a commitment by OAKWORKS Inc OAKWORKS Inc encourages requests for technical specifica tions and the like documen...

Page 3: ...Comfort ABC System Option 13 Integrated Heated Top Option 14 QuickLock Face Rest Accessory Option 15 Adjustable Side Arm Rests Accessory Option Salon Only 16 Boiance Shelf Support Accessory Option 17...

Page 4: ...CRIPTION SYMBOL IDENTIFICATION PRODUCT USE DESCRIPTION SYMBOL IDENTIFICATION 1 The Oakworks Clinician Premiere offers a variety of positioning capabilities for massage therapists and spa professionals...

Page 5: ...ibed in these instructions Do not use attachments not rec ommended by the manufacturer 7 To disconnect turn all controls to the off position then remove plug from outlet 8 Improper connection of the e...

Page 6: ...or should read these sections carefully Weight Limit client and accessories 500 lbs 227 kg Do not exceed Adjustable Breast Comfort ABC System Weight Limit 100 lbs 45 kg Do not sit on the ABC System On...

Page 7: ...s equipped with a cord having an equipment grounding conductor and a grounding pin The pin must be plugged into an appropri ate outlet that is properly installed and grounded in accordance with all lo...

Page 8: ...ll powered motions Hand Control All powered motions Table Voltage Options 120V 60Hz 230V 50Hz Table Capacity 500 lbs 227 kg client and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 73 185 cm...

Page 9: ...st footrest or optional ABC functions of the table PRODUCT DESCRIPTION Backrest Down Backrest Up Height Down Height Up Footrest Down Footrest Up 9 1 P N 71567 2 P N 71569 2 Backrest DOWN P N 71569 1 P...

Page 10: ...20V 60Hz 230V 50Hz Table Capacity 500 lbs 227 kg client and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 73 185 cm Padding 4 10 cm or 6 15 cm Aerocel Foam Table Weight 170 lbs 77 kg OPTIONS...

Page 11: ...ht of the table and operate the optional ABC PRODUCT DESCRIPTION CONTROL OPERATIONS FLAT TOP TABLES DOWN UP 8 Height UP P N 71569 1 Height DOWN P N 71569 1 P N 71568 1 Height Down ABC Down ABC UP N 71...

Page 12: ...le for accessories This product is equipped with an interior 120 volt 60Hz six plug accessory outlet The total electrical load of equipment plugged into this set of outlets is not to exceed 7 amps or...

Page 13: ...revent unauthorized use Remove the key when not in use and store out of reach of children HYDRAULIC DAILY CYCLING The Clinician Premiere uses hydraulics and hydraulic fluids to adjust the table height...

Page 14: ...bs 86 kg Four people are required to move the table safely Do not use the table to transport a client DIRECTIONS FOR USE Position at low height TABLE LEVELING INSTRUCTIONS 1 Place the table in the loc...

Page 15: ...crews If the thumbs screws are on too tight a 3 16 bit can be used 2 Lift top pad off the platform IF THE TABLE HAS A HEATED TOP Unplug the table from the wall outlet and disconnect the wires circled...

Page 16: ...ometimes going back up a little will be preferred This whole process takes no more than 15 20 seconds After lowering check headrest position to ensurecomfort support NOTE Breastsizeisnottheonlydetermi...

Page 17: ...e 2 controls the lower half of the pad Press both but tons located on the right side of the table in the seat section to turn on both zones and heat the entire top BLINKING LIGHTS If one or both contr...

Page 18: ...to the bracket until bullet catches are snapped into place To remove the QuickLock Face Rest gently pull the headrest by the dowels until it comes free Set it safely aside or store it inside the under...

Page 19: ...rest at a 60 angle to the backrest 2 Push end all the way into the hole and drop the arm rest into the horizontal position Pull outward to make sure the arm rest is secure TO LEVEL THE ARM RESTS The...

Page 20: ...head support Note The QuickLock Face Rest is required to use the boiance shelf support system TO INSTALL THE BOIANCE SHELF SUPPORT First install the QuickLock Face Rest at the head end of the table 1...

Page 21: ...Position Bluetooth Speaker with the magnetic attachment facing up Plug the cord into the side of the speaker and attach it to the bracket CONNECTING TO BLUETOOTH SPEAKER Turn Bluetooth Speaker on by p...

Page 22: ...e controls again If one or more of the controls still do not work contact Customer Service at 717 235 6807 to arrange replacement IF THE TABLE IS MAKING NOISE DURING HEIGHT ADJUSTMENT CAUTION Disconne...

Page 23: ...edure Because of possible chemical incompatibilities between various cleaning products and bleach utmost care must be taken by the user to avoid potential exposure to harmful or toxic by prod ucts of...

Page 24: ...PECTIONS yearly or local standard Check for damage to the power hands control and foot control cables and all visible wiring Visually inspect components for obvious damage that could cause problems du...

Page 25: ...ted on the underside of the foot section of the table top Model and Serial numbers always start with a letter 16796025 CPSA4EF1T411USXXPW Ser PAD123456 Clinician Premiere 4 Sect SA 4EF 1 T 4 11 US XX...

Page 26: ...ions 48 2 L x 22 2 W x 14 0 H 122 4cm L x 57 2cm W x 35 6cm H Opening Dimensions Head End 20 0 L x 12 0 H 50 8cm L x 30 5cm H Opening Dimensions Foot End 19 8 L x 12 0 H 50 3cm L x 30 5cm H SPECIFICAT...

Page 27: ...40 C 20 to 60 RH 98 to 105 kPa Storage Transport 20 29 C to 135 57 C 20 to 95 RH 98 to 105 kPa 24 ELECTRICAL SPECIFICATIONS Designed for North America Europe Input Service 120V 60Hz 12 0 Amps 220V 60H...

Page 28: ...Phone 717 235 6807 FAX 717 235 6798 www oakworks com USER MANUAL 3034177 CONFORMS TO UL STD 962 Certified to CAN CSA STD C22 2 68 Original Instructions Manual Part Number SPA RA PM 141 Revision Level...