background image

This symbol, when used in this manual and on product labels, represents a caution warning. 

Be sure to read and comply with all precautions and warnings. 

This symbol, when used in this manual and on product labels, warns against an electrical 

shock hazard. Be sure to observe and comply with all warnings.

This symbol, when used in this manual or on product labels, indicates a Protective Earth 

(Ground) Terminal.

This symbol, when used in this manual or on product labels, indicates the date of manufac-

ture of the device.

This symbol, when used in this manual or on product labels, indicates alternating  

current (AC).

This symbol, when used in this manual or on product labels, indicates direct current (DC).

This symbol is used to indicate that the operator should consult the user manual.

U L   2 60 1 - 1

C S A   C 22 . 2  N O . 6 0 1 . 1

I E C  6 06 0 1 - 2  ( 2 00 1 - 0 9 )

CC

U S

U S

LL IISS TT EE DD

R

U L   2 60 1 - 1

C S A   C 22 . 2  N O . 6 0 1 . 1

I E C  6 06 0 1 - 2  ( 2 00 1 - 0 9 )

CC

U S

U S

LL IISS TT EE DD

R

~

----

PRODUCT USE DESCRIPTION

Oakworks Clinician Electric-Hydraulic and Manual-Hydraulic

 

Series offer a variety of positioning capabili-

ties for massage therapists and spa professionals of all specialties. On these multifunctional professional 

tables the practitioner can perform numerous protocols with ease and comfort. The Clinician Electric-

Hydraulic and Manual-Hydraulic

 

Series are especially effective when professional protocols require spe-

cific positioning for the client. While the client receives comfortable, relaxing support, the comfort level of 

the therapeutic professional is enhanced by superior ergonomics. 

It is intended to be operated by Massage Therapists in a professional environment. No special training 

is required but a review of the following Safety Instructions is important for the safety of the operator and 

client. The massage professional should read and understand this entire manual before use with a client. 

There are no known contraindications to the use of this equipment.

The Clinician Electric-Hydraulic and Manual-Hydraulic

 

Series should not be used in any other manner than 

that described within this manual. Use of any unnecessary force or unauthorized procedures could result 

in injury to practitioner, client or equipment.

SYMBOL IDENTIFICATION

CAUTION

READ AND SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

The use of accessories, transducers, and cables other than those specified by the manufacturer, may result in 

increased emissions or decreased immunity of the table.

PRODUCT USE DESCRIPTION / IMPORTANT SAFETY INSTRUCTIONS

1

Summary of Contents for Clinician Hydraulic

Page 1: ...ist Backrest Top USER MANUAL www OAKWORKS com 717 235 6807 Clinician Manual Hydraulic 1 Section Flat Top Clinician Electric Hydraulic 4 Section Lift Assist Salon Top Clinician Electric Hydraulic 2 Section Lift Assist Backrest Top Clinician Electric Hydraulic 1 Section Flat Top OAKWORKS Clinician Hydraulic ...

Page 2: ...ed within this document is subject to change without notice and should not be construed as a commitment by OAKWORKS Inc OAKWORKS Inc encourages requests for technical specifications and the like documentation to ensure accuracy The appropriate documentation is available upon request OAKWORKS Inc shall not be liable for incidental or consequential damages in connection with or arising out of the fu...

Page 3: ... Daily Cycling 13 Key Lock Use 13 Manual Hydraulic Height Adjustment 14 Lift Assist Backrest Adjustment 15 Lift Assist Leg Rest Adjustment 15 Moving the Table 16 Leveling the Table 16 Removing Top Pad 17 Adjustable Breast Comfort ABC System Option 18 Integrated Heated Top Option 19 QuickLock Face Rest Accessory Option 20 Adjustable Side Arm Rests Accessory Option Salon Only 21 Boiance Shelf Suppor...

Page 4: ...cialties On these multifunctional professional tables the practitioner can perform numerous protocols with ease and comfort The Clinician Electric Hydraulic and Manual HydraulicSeries are especially effective when professional protocols require spe cific positioning for the client While the client receives comfortable relaxing support the comfort level of the therapeutic professional is enhanced b...

Page 5: ... administered Do not lift table by the table top This can damage the table When lowering the table make sure there is nothing underneath the table top that can impede motion like stools cabinets accessory parts cleaners etc Use this furnishing only for its intended use as described in these instructions Do not use attachments not recommended by the manufacturer Close supervision is necessary when ...

Page 6: ...e Options 120V 60Hz 230V 50Hz Table Capacity 500 lbs 227 kg client and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 73 185 cm Padding 4 10 cm or 6 15 cm Aerocel Foam Table Weight 155 lbs 70 kg OPTIONS Adjustable Breast Comfort ABC System Wood Finishes Storage Cabinet w Sliding Doors Hand Control Integrated Heated Top ACCESSORIES QuickLock Face Rest Boiance Shelf Support Side Arm Rests F...

Page 7: ...ase Operate the foot control and or optional hand control as shown below to raise or lower the height or optional ABC function of the table P N 71567 1 P N 71569 1 P N 71568 1 P N 71567 2 P N 71569 2 DOWN UP Height UP P N 71569 1 P N 71568 1 Height DOWN P N 71567 1 P N 71569 1 P N 71568 1 Height Down ABC Down ABC UP P N 71567 1 P N 71569 1 P N 71568 1 P N 71567 2 P N 71569 2 ABC DOWN P N 71567 1 P...

Page 8: ...ange Table Voltage Options 120V 60Hz 230V 50Hz Table Capacity 500 lbs 227 kg client and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 73 185 cm Padding 4 10 cm or 6 15 cm Aerocel Foam Table Weight 150 lbs 68 kg OPTIONS Adjustable Breast Comfort ABC System Wood Finishes Storage Cabinet w Sliding Doors Hand Control Integrated Heated Top ACCESSORIES QuickLock Face Rest Boiance Shelf Support...

Page 9: ...rol and or optional hand control as shown below to raise or lower the height or optional ABC function of the table PRODUCT DESCRIPTION P N 71567 1 P N 71569 1 P N 71568 1 P N 71567 2 P N 71569 2 DOWN UP Height UP P N 71569 1 P N 71568 1 Height DOWN P N 71567 1 P N 71569 1 P N 71568 1 Height Down ABC Down ABC UP P N 71567 1 P N 71569 1 P N 71568 1 P N 71567 2 P N 71569 2 ABC DOWN P N 71567 1 P N 71...

Page 10: ...t Range Table Voltage Options 120V 60Hz 230V 50Hz Table Capacity 500 lbs 227 kg client and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 73 185 cm Padding 4 10 cm or 6 15 cm Aerocel Foam Table Weight 145 lbs 66 kg OPTIONS Adjustable Breast Comfort ABC System Wood Finishes Storage Cabinet w Sliding Doors Hand Control Integrated Heated Top ACCESSORIES QuickLock Face Rest Boiance Shelf Supp...

Page 11: ...optional ABC function of the table P N 71567 1 P N 71569 1 P N 71568 1 P N 71567 2 P N 71569 2 DOWN UP Height UP P N 71569 1 P N 71568 1 Height DOWN P N 71567 1 P N 71569 1 P N 71568 1 Height Down ABC Down ABC UP P N 71567 1 P N 71569 1 P N 71568 1 P N 71567 2 P N 71569 2 ABC DOWN P N 71567 1 P N 71569 1 P N 71568 1 P N 71567 2 P N 7 ABC SYSTEM UP ABC SYSTEM DOWN ABC Up Height Up FOOT CONTROL WITH...

Page 12: ...anual 0 30º Leg Rest Table Voltage Options 120V 60Hz 230V 50Hz Table Capacity 500 lbs 227 kg client and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 73 185 cm Padding 4 10 cm or 6 15 cm Aerocel Foam Table Weight 140 lbs 63 5 kg OPTIONS Wood Finishes Storage Cabinet w Sliding Doors Integrated Heated Top ACCESSORIES QuickLock Face Rest Boiance Shelf Support Side Arm Rests 9 ...

Page 13: ...0 80º Backrest Table Voltage Options 120V 60Hz 230V 50Hz Table Capacity 500 lbs 227 kg client and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 73 185 cm Padding 4 10 cm or 6 15 cm Aerocel Foam Table Weight 135 lbs 61 kg OPTIONS Wood Finishes Storage Cabinet w Sliding Doors Integrated Heated Top ACCESSORIES QuickLock Face Rest Boiance Shelf Support 10 ...

Page 14: ...Voltage Options 120V 60Hz 230V 50Hz Table Capacity 500 lbs 227 kg client and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 73 185 cm Padding 4 10 cm or 6 15 cm Aerocel Foam Table Weight 130 lbs 59 kg OPTIONS Wood Finishes Storage Cabinet w Sliding Doors Integrated Heated Top ACCESSORIES QuickLock Face Rest Boiance Shelf Support 11 ...

Page 15: ...is equipped with a cord having an equipment grounding conductor and a grounding pin The pin must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances See U S sample below Correct Implementation Incorrect Implementation Risk of Electric Shock Connect this furnishing to a properly grounded outlet only DANGER INSTALLATION GROU...

Page 16: ...sed to prevent unauthorized use Remove the key when not in use and store out of reach of children HYDRAULIC DAILY CYCLING The Clinician Series uses hydraulics and hydraulic fluids to adjust the table height Maintaining the quiet operation of your table requires that you fully cycle your table up down twice per day Cycling of the table will maintain the lubrication within the hydraulic cylinders fo...

Page 17: ...se to raise the table to the desired height To lower the table turn the handle counter clockwise To fold handle out of the way rotate until the handle is at its lowest point then pull out slightly Fold down under the table Note Folding the handle when it is not at its lowest point can damage the area around the handle Raise table Lower table 14 ...

Page 18: ...d that clients take some of their weight of the leg rest while you lift TO LOWER THE LEG REST Pull the lever on the side of the leg section and push the leg section down Release the lever once the leg rest is at its desired location and the leg section will stay in place TO CHANGE POSITION OF THE LEG REST LEVER The leg rest lever can be moved to the opposite side of the table First remove the scre...

Page 19: ...o move the table safely Do not use the table to transport a client DIRECTIONS FOR USE Grasp at base end rail At low height range TABLE LEVELING INSTRUCTIONS 1 Place the table in the location where you plan to use it 2 Rock the table to determine if it is level with the floor If the table rocks back and forth at all the foot that clears the floor when you rock the table will need adjustment 3 Adjus...

Page 20: ...screws If the thumbs screws are on too tight a 3 16 bit can be used 2 Lift top pad off the platform IF THE TABLE HAS A HEATED TOP Unplug the table from the wall outlet and disconnect the wires circled from the control box located under the platform Pull the cables through the platform before completely removing the top pad TO REMOVE THE TOP PAD The top pad is attached to the platform with 8 thumb ...

Page 21: ...able Sometimes going back up a little will be preferred This whole process takes no more than 15 20 seconds After lowering check headrest position to ensurecomfort support NOTE Breastsizeisnottheonlydeterminateofcush ion location Every person s comfort spot is different regardless of breast size If you are using the head rest in the Supine posi tion you may use the cushion at relatively high heigh...

Page 22: ...of the pad while Zone 2 controls the lower half of the pad Press both but tons located on the right side of the table in the seat section to turn on both zones and heat the entire top BLINKING LIGHTS If one or both controllers heat level indicator lights are blinking the heating elements are not con nected properly and or damaged Unplug the table and locate the control box es on the underside of t...

Page 23: ...nto the bracket until bullet catches are snapped into place To remove the QuickLock Face Rest gently pull the headrest by the dowels until it comes free Set it safely aside or store it inside the under table cabinet until needed To use the face rest with your clients supine rotate the face rest pad so that the thick part of the pad supports your client s cervical region Adjusting the height and an...

Page 24: ...m rest at a 60 angle to the backrest 2 Push end all the way into the hole and drop the arm rest into the horizontal position Pull outward to make sure the arm rest is secure TO LEVEL THE ARM RESTS The Arm Rest height is adjusted at the factory for each table If the armrest starts to sag with repeated use follow the steps below to readjust 1 Loosen the bottom 2 set screws 2 Turn the side set screw ...

Page 25: ... head support Note The QuickLock Face Rest is required to use the boiance shelf support system TO INSTALL THE BOIANCE SHELF SUPPORT First install the QuickLock Face Rest at the head end of the table 1 Position bracket under neath QuickLock 2 Hook bracket onto cen ter support beam on the QuickLock 3 Lower the bracket down Make sure bracket is engaged with the dowels on the side of QuickLock 4 Slide...

Page 26: ... head end of the table Position Bluetooth Speaker with the magnetic attachment facing up Plug the cord into the side of the speaker and attach it to the bracket CONNECTING TO BLUETOOTH SPEAKER Turn Bluetooth Speaker on by pressing the power button Connect a bluetooth device by pressing the bluetooth button and pairing on the bluetooth device ...

Page 27: ...cedure Because of possible chemical incompatibilities between various cleaning products and bleach utmost care must be taken by the user to avoid potential exposure to harmful or toxic by prod ucts of the combination Also because bleach leaves a potentially corrosive residue as it evaporates it must be rinsed with clean water after disinfection Use of non approved cleaners or disinfectants may lea...

Page 28: ...les and all visible wiring Visually inspect components for obvious damage that could cause problems during operation Check all mechanical functions using the hand control Repeat using the foot control Check for abnormal noises Check that all fasteners are present and fastened securely Check table grounding Clean unusual buildup of dirt on the table and or parts of the table not normally cleaned on...

Page 29: ...e located on the underside of the foot section of the table top Model and Serial numbers always start with a letter 16796025 CFSA4LF1T410USXXPW Ser CFK123456 06 03 2020 Order 785461 Clinician Electric Hydraulic LA Salon 1 T 4 11 US XX PW TT Stone Notes XXX Model Number Serial Number 26 ...

Page 30: ...ed for North America Europe Input Service 120 VAC 12 amp 60 Hz 220 VAC 5 amp 50 60 Hz Current Draw 5 0 amps 2 5 amps Made of Operation Intermittent Operation MAX 2 minutes ON 18 minutes off Intermittent Operation MAX 2 minutes ON 18 minutes off CABINET DIMENSIONS Total Inside Dimensions 53 L x 21 W x 10 H 135cm L x 53cm W x 25cm H Opening Dimensions Head End 26 L x 10 H 65cm L x 25cm H Opening Dim...

Page 31: ...THIS PAGE IS INTENTIONALLY LEFT BLANK 28 ...

Page 32: ... Phone 717 235 6807 FAX 717 235 6798 www oakworks com USER MANUAL 3034177 CONFORMS TO UL STD 962 Certified to CAN CSA STD C22 2 68 Original Instructions Manual Part Number SPA RA PM 152 Revision level 3 Revision Date 04 09 2021 English Printed in USA OAKWORKS Clinician Hydraulic ...

Reviews: