background image

DIRECTIONS FOR USE

HOT TOWEL CABI SHELF & STORAGE SHELF

CAUTION

• 

The Anti-Tip Strap must be installed when using a Hot Towel Cabi. 

• 

Do not overload the storage Shelf. [Max load weight is 25 lbs. (11.3 kg)]

• 

Do not use electrical devices that require more than 15 amps with the power strip. 

• 

Make sure all cords are safely located out of the way to avoid trip hazards. 

• 

Make sure no cords are pinched when the table is raised and lowered. 

• 

Open the Hot Towel Cabi slowly to prevent hot steam from burning the client when it is 

located and the head end of the table. 

The Cabi Shelf holds a Hot Towel Cabi with dimensions 

no greater than 

17.9” W x 12.6” D x 11.4” H.

 

Place the Hot Towel Cabi on the Cabi Shelf and center it. 

Wrap the Anti-Tip Strap tightly around the Cabi and shelf 

as shown to secure it against tipping. 

Anti-Tip

Strap

PRODUCT USE: 

The shelves are designed to provide storage areas for items needed during treatment and equipment. The 

shelves will change the overall height range of the table. 

Storage 

Shelf

Cabi 

Shelf

CABI SHELF DIRECTIONS FOR USE: 

Plug Hot Towel Cabi into the Power Strip located on the 

table rail or underneath the platform. Make sure all cords 

are out of the way to prevent a trip hazard. 

15

Power 

Strip

Summary of Contents for OAKWORKS ProLuxe Series

Page 1: ...USER MANUAL www oakworks com 717 235 6807 OAKWORKS ProLuxe Series...

Page 2: ...within this document is subject to change without notice and should not be construed as a commitment by OAKWORKS Inc OAKWORKS Inc encourages requests for technical specifica tions and the like documen...

Page 3: ...Cabi Storage Shelf 15 Removing Top Pad 16 Adjustable Breast Comfort ABC System Option 17 Integrated Heated Top Option 18 QuickLock Face Rest Accessory Option 19 Adjustable Side Arm Rests Accessory Op...

Page 4: ...ON IMPORTANT SAFETY INSTRUCTIONS PRODUCT USE DESCRIPTION Oakworks ProLuxe Series offers a variety of positioning capabilities for massage therapists and spa professionals of all specialties On these m...

Page 5: ...not use attachments not rec ommended by the manufacturer 7 To disconnect turn all controls to the off position then remove plug from outlet 8 Improper connection of the equipment grounding conductor...

Page 6: ...or should read these sections carefully Weight Limit client and accessories 550 lbs 250 kg Do not exceed Adjustable Breast Comfort ABC System Weight Limit 100 lbs 45 kg Do not sit on the ABC System On...

Page 7: ...like the plug shown below See Grounding Methods US 120V Example Make sure that the product is connected to an outlet having the same configuration as the plug No adapter should be used with this produ...

Page 8: ...ble Capacity 550 lbs 250 kg client and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 73 185 cm Padding 4 10 cm or 6 15 cm Aerocel Foam Table Weight 200 lbs 91 kg Height Range with Cabi Stora...

Page 9: ...ease Operate the foot and or optional hand control as shown below to raise or lower the height backrest footrest or optional ABC functions of the table Backrest Down Backrest Up Height Down Height Up...

Page 10: ...Capacity 550 lbs 250 kg client and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 73 185 cm Padding 4 10 cm or 6 15 cm Aerocel Foam Table Weight 190 lbs 86 kg Height Range with Cabi Storage...

Page 11: ...1 P N 71569 1 P N 71568 1 Height Down ABC Down ABC UP P N 71567 1 P N 71569 1 P N 71568 1 P N 71567 2 P N 71569 2 ABC DOWN P N 71567 1 P N 71569 1 P N 71568 1 P N 71567 2 P N ABC SYSTEM UP ABC SYSTEM...

Page 12: ...ty 550 lbs 250 kg client and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 73 185 cm Padding 4 10 cm or 6 15 cm Aerocel Foam Table Weight 180 lbs 82 kg Height Range with Cabi Storage Shelves...

Page 13: ...P N 71567 1 P N 71569 1 P N 71568 1 Height Down ABC Down ABC UP P N 71567 1 P N 71569 1 P N 71568 1 P N 71567 2 P N 71569 2 ABC DOWN P N 71567 1 P N 71569 1 P N 71568 1 P N 71567 2 P N ABC SYSTEM UP...

Page 14: ...Hz 230V 50Hz Table Capacity 550 lbs 250 kg client and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 73 185 cm Padding 4 10 cm or 6 15 cm Aerocel Foam Table Weight 170 lbs 70 kg Height Range...

Page 15: ...ate the optional ABC DOWN UP Height UP P N 71569 1 P N 71568 1 Height DOWN P N 71567 1 P N 71569 1 P N 71568 1 Height Down ABC Down ABC UP P N 71567 1 P N 71569 1 P N 71568 1 P N 71567 2 P N 71569 2 A...

Page 16: ...that clients take some of their weight of the leg rest while you lift TO LOWER THE LEG REST Pull the lever on the side of the leg section and push the leg section down Release the lever once the leg r...

Page 17: ...le top to protect the surface from any debris from the bottom of your foot control Two people are required to safely move the table Grasp the table frame securely at the end with the molded rubber fee...

Page 18: ...is located and the head end of the table The Cabi Shelf holds a Hot Towel Cabi with dimensions no greater than 17 9 W x 12 6 D x 11 4 H Place the Hot Towel Cabi on the Cabi Shelf and center it Wrap t...

Page 19: ...crews If the thumbs screws are on too tight a 3 16 bit can be used 2 Lift top pad off the platform IF THE TABLE HAS A HEATED TOP Unplug the table from the wall outlet and disconnect the wires circled...

Page 20: ...ometimes going back up a little will be preferred This whole process takes no more than 15 20 seconds After lowering check headrest position to ensurecomfort support NOTE Breastsizeisnottheonlydetermi...

Page 21: ...f the pad while Zone 2 controls the lower half of the pad Press both but tons located on the right side of the table in the seat section to turn on both zones and heat the entire top BLINKING LIGHTS I...

Page 22: ...to the bracket until bullet catches are snapped into place To remove the QuickLock Face Rest gently pull the headrest by the dowels until it comes free Set it safely aside or store it inside the under...

Page 23: ...rest at a 60 angle to the backrest 2 Push end all the way into the hole and drop the arm rest into the horizontal position Pull outward to make sure the arm rest is secure TO LEVEL THE ARM RESTS The...

Page 24: ...head support Note The QuickLock Face Rest is required to use the boiance shelf support system TO INSTALL THE BOIANCE SHELF SUPPORT First install the QuickLock Face Rest at the head end of the table 1...

Page 25: ...d end of the table Position Bluetooth Speaker with the magnetic attachment facing up Plug the cord into the side of the speaker and attach it to the bracket CONNECTING TO BLUETOOTH SPEAKER Turn Blueto...

Page 26: ...edure Because of possible chemical incompatibilities between various cleaning products and bleach utmost care must be taken by the user to avoid potential exposure to harmful or toxic by prod ucts of...

Page 27: ...o wipe off any excess grease RECOMMENDED PERIODIC INSPECTIONS yearly or local standard Check for damage to the power hands control and foot control cables and all visible wiring Visually inspect compo...

Page 28: ...number are located on the underside of the foot section Serial Number 16796025 PXXA4EX1T410USXXXXXX Ser PXR563146 Proluxe Electric Salon w ABC 1 T 4 10 US XX XX XX TTSKYBLUE 01 01 2020 Order 654321 No...

Page 29: ...LE DIMENSION ELECTRIC SALON LIFT ASSIST 26 TABLE DIMENSION FLAT TOP CABI SHELF DIMENSIONS 19 5 L x 9 W x 11 88 H 49 5cm L x 23cm W x 30 25cm H STORAGE SHELF DIMENSIONS 19 5 L x 13 W x 8 63 H 49 5cm L...

Page 30: ...57 C 20 to 95 RH 98 to 105 kPa ELECTRICAL SPECIFICATIONS Designed for North America Europe Input Service 120 VAC 15 amp 60 Hz 230 VAC 10 amp 50 60 Hz Current Draw 2 7 amps 1 5 amps Maximum Momentary...

Page 31: ...ectromagnetic environment in which radiated RF disturbances are con trolled The customer or the user of the table can help prevent electromagnetic interference by maintaining a minimum distance betwee...

Page 32: ...al mode 2 kV common mode 1 kV differential mode 2 kV common mode Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interrup tions and voltage variat...

Page 33: ...F transmitters as deter mined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the...

Page 34: ...31 THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 35: ...32 THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 36: ...MS TO ANSI AAMI STD ES60601 1 IEC STD 60601 1 3RD EDITION IEC STD 60601 1 2 3RD EDITION IEC STD 60601 1 6 3RD EDITION CERTIFIED TO CAN CSA STD C22 2 NO 60601 1 CB TEST CERTIFICATE AND REPORT OAKWORKS...