4. Precautions
1.
Handle with care. Your instrument uses a precise mechanism
to expand and contract the pressure chamber. Rough treat-
ment can damage the mechanism.
2.
Avoid direct contact with water and high levels of
condensation. This instrument is not waterproof, and its
vents are intended only for air circulation.
3.
Because the thermometer is also made with precision parts,
the instrument must not be stored in extreme temperatures.
Avoid rapid temperature changes and strong physical shocks.
The instrument must not be placed near heating units or in
direct sunlight.
4.
For accurate barometric pressure readings, keep the
instrument in a vertical position.
5.
Dismantling the instrument can affect its accuracy.
6.
Remove stains with a soft cloth and mild detergent.
7.
Never use in environments that contain solvents like acetone,
benzene, alcohol, or acids and bases.
Model number
03316-70
Barometric pressure
Range
930 to 1070 mbar / 27.5" to 31.6 "Hg
Resolution
1 mbar / 0.1 "Hg
Accuracy
±1 mbar / ±0.03 "Hg
Temperature
Range
–5 to 55°C / –22 to 132°F
Resolution
1°C / 2°F
Accuracy
±1°C / ±1.8°F
Sensor
kerosene filled glass thermometer
Altitude
use between sea level and 2000 feet
Power
none required
Case
brass
Dimensions
7
1
⁄
8
" dia x 2
1
⁄
8
" D
Shpg wt.
3 lbs