Work Order #
Orifice # (Main)
BTU Rating
Orifice # (OTHER)
Serial #
Leak Test
Model #
Burn Test
Air Shutter
Gas Type
Inspector:
After The Unit Is Converted, it Must Be Tested
to Verify the Inlet and Manifold pressures are as
specified on Page 3. Additionally, the
authorized representative must verify that the
input rate of the converted appliance match the
rate listed below.
LP 65,000 / NG 65,000
Date
If you are converting from propane (LP) gas to natural gas, install the air shutter sleeve so that the air intake holes are closed (Figure
#2). For Propane gas, remove the air shutter so that the air intake holes are open (Figure #1).
After the unit is assembled for use, it
is requires a "leak check" test on all connections are before placing the unit in operation.
6.
IT IS NECESSARY TO ATTACH THE LABEL OR RATING PLATE INCLUDED WITH THE CONVERSION KIT TO CLEARLY
INDICATE THE FIELD CONVERSION.
1.
Important: "Any guard or other protective device removed for gas conversion or servicing the appliance shall be replaced
prior to operating the appliance.” Contact your local dealer for the required conversion kit.
MANUFACTURER’S USE ONLY - QUALITY CHECK
Follow steps 1 – 6 shown above.
THE CONVERSION SHALL BE CARRIED OUT BY A
MANUFACTURER’S AUTHORIZED
REPRESENTATIVE, IN ACCORDANCE WITH THE
REQUIREMENTS OF THE MANUFACTURER,
PROVENCIAL OR TERRITORIAL AUTHORITIES
HAVING JURISDICTION AND IN ACCORDANCE
WITH THE REQUIREMENTS OF THE
CAN/CGA-B149.1 OR CAN/CGA-B149.2
INSTALLATION CODES.
After conversion follow Operating Instructions
found on Page 11.
Casual Fireside Fire Pits Are
Suitable For Installation from
0 - 4,500 ft. Without Modification.
X
#13 / COM0568CK
Page 12
FIGURE 2
COM0568
#42
LP - NAT
CONVERTING YOUR FIRE PIT TO A DIFFERENT GAS TYPE
2.
MAKE SURE THAT THE GAS SUPPLY TO THE FIRE PIT (AND ANY NEARBY ELECTRICAL SOURCES/APPLIANCES) ARE
SHUT OFF.
3.
FIGURE 1
Carefully detach the flex line connector hose attached to the orifice holder (Figure # 1) and unscrew the orifice holder from the burner
pipe (Figures #1 and # 2).
4.
Remove the orifice from the holder (Figure # 2 ) and replace it with the proper sized one for your gas requirement. Propane requires
the smaller orifice.
5.
Orifice
Orifice
Holder
Burner
When
converting to
natural
gas,
the
air
shutter
sleeve MUST
be
installed
over
the
burner
pipe.
Flex
Line
Connector Hose
Burner
Orifice
Holder
Flex
Line
Orifice
Air
Intake hole
open
for
LP
Gas