background image

 

1.  Press the “Fan Select” button to initiate fan settings. 

Pushing the “Fan Select” button continuously will scroll 
through the connections on the meter.  

2.  Push the “Up and Down Arrows” to adjust the fan speed, 

note that doing this will set the meter into Manual mode. 
The fan speed range that can be adjusted is 
automatically detected by the fan controller. Setting a 
fan to 0 RPM results in turning off the fan. Due to 
information being passed between the meter and the 
fan, please allow up to 1 minute for fans to adjust to the 
RPM. 

3.  The Sentry LX will exit the “Fan Select” mode at after 

idling or at the end of the “Fan Select” scroll. 

Temperature Alarm Settings 

The Sentry LX allows for alarm setting for temperatures, the default 
is set at 70C, these settings will be saved. A sound alarm will go off if 
the temperature detected rises above the set temperature. Please 
follow the directions below: 

1.  Press and hold the triangular “Down Arrow Key” to 

initiate temperature alarm setting. 

2.  Pushing the “SET” button to scroll through the 

temperature settings for the 5 probes.  

3.  Use the “Up and Down Arrows” to adjust the 

temperatures. 

4.  The Sentry LX will exit the temperature alarm setting 

mode at after idling or at the end of the “SET” button 
scroll.  

Date, Time, Mode and Alarm Off Setting 

In this mode the date, temperature alarm on/off, time, can be adjust. 
Please follow the directions below: 

1.  Push the “SET” button to begin this mode.

 

2.  Continue to push the set button to scroll through the 

options

 

NZXT. 4 

Summary of Contents for Sentry LX

Page 1: ...Sentry LX User s manual ...

Page 2: ......

Page 3: ...arket today Since then we have stayed true to our goal which was to continuously provide innovative next generation products With every product we are still breaking more boundaries and limits Once again thank you and all NZXT fans for the support and we hope to bring more amazing products in the coming years After you complete your installation please come by our community forums at www nzxt com ...

Page 4: ...h over the temperatures of your system Temperature alarm Make sure you are notified when your system is overheating Calendar System Big letters show you time date and day of the week Table of Contents Thank you 1 Sentry LX Specifications 2 Setting up the Sentry LX 3 Installing the Sentry LX 3 Setting up the fans and probes 3 Auto Manual Fan Speed Settings 3 Temperature Alarm Settings 4 Date Time M...

Page 5: ...rature probes 1 Make sure your system is off before making any connections 2 Connect the 3pin connection on the Sentry LX to the fans on your chassis 3 Note the stickers on the 3pin connections correspond to the number on the meter display It is recommended that the user tape the temperature probes near the corresponding fans i e Fan 1 is near Temp 1 probe this optimizes the Auto mode where the fa...

Page 6: ...larm Settings The Sentry LX allows for alarm setting for temperatures the default is set at 70C these settings will be saved A sound alarm will go off if the temperature detected rises above the set temperature Please follow the directions below 1 Press and hold the triangular Down Arrow Key to initiate temperature alarm setting 2 Pushing the SET button to scroll through the temperature settings f...

Page 7: ...button during the alarm sound process will disable the sound early Reset to Default settings Simply pressing the RESET key will return the meter to factory settings NOTE All previous settings will be deleted Support and Service If you have any more questions or have problems with the NZXT product you purchased please don t hesitate to contact service nzxt com along with a detailed explanation of y...

Reviews: