Do not use any other input power cord other than the one provided with the unit.  If the 
input power cord is lost or missing contact the seller to procure a replacement cord.  

The outlet must consist of a Line, Neutral and Ground (DO NOT plug the power conditioner into 
an ungrounded outlet or use any kind of ground removing plug (commonly called “cheater 
plugs”) to power the conditioner.  If the power conditioner is equipped with a power on circuit 
breaker switch turn the switch to the 

ON

 position.  The blue power 

ON

 indicator (light) on the 

front of the unit will illuminate.  Once the power conditioner is plugged in and turned on, insure 
the “Site Wiring Fault” LED (120 VAC North American models only) on the rear of the unit is not 
flashing.  If this LED is flashing contact a qualified electrician immediately to insure proper wiring 
of the mains outlet.  The power conditioner must not be plugged into this outlet until the wiring 
problem is corrected.  If the “wiring fault” LED is not ON or flashing, you can turn on the load 
equipment/electronic devices. If you have any questions in this regard, contact the seller. 

Note: If the power conditioner is mounted to a wall the installation can be in the horizontal position 
facing left or right.  If the power conditioner is mounted vertically the unit must be installed with front 
plastic panel facing the ground.   

All 

NXT POWER 

Conditioners are equipped with overload protection and this protection will turn 

off the power conditioner if overloaded.  If the power conditioner turns off due to an overload, 
remove some of the load equipment/electronic devices from the conditioner and turn the power 
conditioner on again.  

Overload Protection device cannot be replaced.

 

These power conditioners are not rated or intended for use in the presence of flammable gas or 
anesthetics as there will be a risk of a of an explosion.  

All power conditioner

s

 use a basic type insulation and a grounded power network must 

be used.

All power conditioners listed below are considered Class 1.

All power conditioners listed below are considered Type B.

There are no user serviceable parts inside the power conditioner, contact the seller for 
service or repair.

All power conditioners use hazardous voltage.

All power conditioners should only be used in ordinary locations.

All Power conditioners can be operated in continuous duty cycle.

All Power conditioners enclosure are IP40 rated.

CAUTION 

CAUTION 

DANGER 

Summary of Contents for NPT 1000

Page 1: ...z NPT 80 120 180 240 360 480 600 720 840 1000 1200 1500 2000 Model Numbers 200 240 VAC 50 60Hz NPT 80 240 480 780 1000 1200 1500 2000 POWER CONDITIONER USER S MANUAL For use with Standard NXT Ground M...

Page 2: ...1 TABLE OF CONTENTS 1 0 INTRODUCTION 2 2 0 SAFETY GUIDELINES 2 3 0 OPERATION MAINTENANCE 3 4 0 POWER CONDITIONER RATINGS CHART 5 5 0 WARRANTY 6 6 0 CONTACT US 7...

Page 3: ...ny additional questions after reviewing this manual please feel free to contact our technical support team by phone 877 697 7697 or email us at service nxtpower com 2 0 SAFETY GUIDELINES Symbol Descri...

Page 4: ...This can be done by making sure the power conditioner is not loaded above its maximum rating please see back panel of the unit for rating information If you have any questions regarding the rating of...

Page 5: ...ote If the power conditioner is mounted to a wall the installation can be in the horizontal position facing left or right If the power conditioner is mounted vertically the unit must be installed with...

Page 6: ...el Number Input Voltage AC Output voltage AC Maximum Load Rating Maximum Power VA Frequency ZI NPT80 XXX i 200 240 200 240 0 35 amps 80 VA 50 60 Hz 6 97 NPT240 XXX i 200 240 200 240 1 0 amps 240 VA 50...

Page 7: ...s not cover any losses or damage resulting from shipment to or from the Customer or from improper installation improper application inappropriate environment abuse neglect unauthorized modifications a...

Page 8: ...ridge IL 60706 P 872 310 4050 F 708 457 2266 E service nxtpower com 022 00001 2020 REV C User Manual Power conditioner 80 VA to 2000VA 120 230 VAC Access additional product and support via our website...

Page 9: ...7051 W Wilson Ave Norridge Il 60706 www nxtpower com...

Reviews: