4.9.2 Count mode
In this mode, an internal counter clocked by the RC oscillator of MAX V counts up and
down, at low speed (clock frequency: 7.6 Hz), or high speed (clock frequency: 61 Hz).
The counting status, direction, and speed are set by the MAX_CTRL_# lines of the
for MAX_CTRL lines. The current value of the counter is sent
to ports P0 and P1 of the DUT IC (configured as inputs) and displayed in the GUI. The
range of the counter value is from 000 to 999.
Bus line
Function
State
Description
0
Low speed (7.5 Hz)
MAX_CTRL_0
Speed
1
High speed (60 Hz)
0
down
MAX_CTRL_1
Direction
1
up
0
Counter is ON
MAX_CTRL_2
Status
1
Counter is OFF (the counting is stopped)
Table 5. MAX_CTRL_# control lines