NXP Semiconductors
UM11758
UJA1169A evaluation boards
6.2.2 HW setup for FlexGUI operation
The watchdog in the SBC must be off while the FlexGUI is running. The watchdog is
always off in Forced Normal mode and off by default in Software Development mode (a
sample script for switching the device to Software Development mode via the FlexGUI is
included in
).
A system reset is generated after programming the MTPNV memory, after which the
connection between the FlexGUI and the board will need to be re-established (see
). If the reconnection fails, try again after a power-off/wait-3-seconds/power-
on sequence on the UJA1169Ax-EVB.
Once the FlexGUI firmware has been installed on the microcontroller board, the
jumpers on the boards need to be set as illustrated in
UJA1169Ax-EVB into the microcontroller board. The resulting supply and data line
interconnections between the boards are shown in
header interconnections are shown in the schematics extract in
board schematics for further details.
Figure 23. UJA1169Ax-EVB/S32K144EVB jumper settings for FlexGUI operation
UM11758
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2022. All rights reserved.
User manual
Rev. 1 — 19 April 2022
24 / 39