MCG_S field descriptions (continued)
Field
Description
0
Source of internal reference clock is the slow clock (32 kHz IRC).
1
Source of internal reference clock is the fast clock (4 MHz IRC).
20.3.8 MCG Status and Control Register (MCG_SC)
Address: 4006_4000h base + 8h offset = 4006_4008h
Bit
7
6
5
4
3
2
1
0
Read
Write
Reset
0
0
0
0
0
0
1
0
MCG_SC field descriptions
Field
Description
7
ATME
Automatic Trim Machine Enable
Enables the Auto Trim Machine to start automatically trimming the selected Internal Reference Clock.
NOTE: ATME deasserts after the Auto Trim Machine has completed trimming all trim bits of the IRCS
clock selected by the ATMS bit.
Writing to C1, C3, C4, and SC registers or entering Stop mode aborts the auto trim operation and clears
this bit.
0
Auto Trim Machine disabled.
1
Auto Trim Machine enabled.
6
ATMS
Automatic Trim Machine Select
Selects the IRCS clock for Auto Trim Test.
0
32 kHz Internal Reference Clock selected.
1
4 MHz Internal Reference Clock selected.
5
ATMF
Automatic Trim Machine Fail Flag
Fail flag for the Automatic Trim Machine (ATM). This bit asserts when the Automatic Trim Machine is
enabled, ATME=1, and a write to the C1, C3, C4, and SC registers is detected or the MCG enters into any
Stop mode. A write to ATMF clears the flag.
0
Automatic Trim Machine completed normally.
1
Automatic Trim Machine failed.
4
FLTPRSRV
FLL Filter Preserve Enable
This bit will prevent the FLL filter values from resetting allowing the FLL output frequency to remain the
same during clock mode changes where the FLL/DCO output is still valid. (Note: This requires that the
FLL reference frequency to remain the same as what it was prior to the new clock mode switch. Otherwise
FLL filter and frequency values will change.)
0
FLL filter and FLL frequency will reset on changes to currect clock mode.
1
Fll filter and FLL frequency retain their previous values during new clock mode change.
Table continues on the next page...
Chapter 20 Multipurpose Clock Generator (MCG)
MKW01Z128 MCU Reference Manual, Rev. 3, 04/2016
Freescale Semiconductor, Inc.
347
Summary of Contents for MKW01Z128
Page 7: ...MKW01xxRM Reference Manual Rev 3 04 2016 viii Freescale Semiconductor Inc...
Page 11: ...MKW01xxRM Reference Manual Rev 3 04 2016 xii Freescale Semiconductor Inc...
Page 133: ...MKW01Z128 MCU Reference Manual Rev 3 04 2016 2 Freescale Semiconductor Inc...
Page 233: ...Module clocks MKW01Z128 MCU Reference Manual Rev 3 04 2016 102 Freescale Semiconductor Inc...
Page 513: ...Interrupts MKW01Z128 MCU Reference Manual Rev 3 04 2016 382 Freescale Semiconductor Inc...
Page 633: ...CMP Trigger Mode MKW01Z128 MCU Reference Manual Rev 3 04 2016 502 Freescale Semiconductor Inc...