Using the BLF574 in the 88 MHz to 108 MHz FM band
Example:
Assuming the device is running at 600 W with the RF output power at 70 %
efficiency on a heatsink (e.g. 40
°
C). T
j
can be determined based on the operating
efficiency for the given heatsink temperature:
•
Dissipated power (P
d
) = 257 W
•
Temperature rise (T
r
) = P
d
×
R
th
= 257 W
×
(0.4
°
C/W) = 103
°
C
•
Junction temperature (T
j
) = T
h
+ T
r
= 40
°
C + 103
°
C = 143
°
C
Based on this, the TTF can be estimated using a device greased-down heatsink as
follows:
•
The operating current is just above 17 A
•
T
j
= 140
°
C
The curve in
intersects the x-axis at 17 A. At this point, it can be estimated that
it would take 100 years for 0.1 % of the devices to fail.