background image

888.901.3633  |  +44 (0) 208 977 6614 |  www.nvtphybridge.com

Copyright 2018 NVT Phybridge  |  445-0009-B  |  Page 2

Technical Specifications

Model Number

EC-Link+

EC-Base

EC4

Part Number 

NV-ECLK-PLS

NV-ECLK-BSE

NV-EC-04

Dimensions

10.09cm x 5.03cm x 2.57cm (LxWxH);
3.97” x 1.98” x 1.01” (LxWxH)

10.09cm x 5.03cm x 2.57cm (LxWxH);
3.97” x 1.98” x 1.01” (LxWxH)

11cm x 7cm x 2.5cm (LxWxH); 
4.3” x 2.75” x 0.98” (LxWxH)

Weight

108g (3.81oz.) 

108g (3.81oz.)

96g (3.38oz.)

Interface: Network 
Infrastructure side 
(CLEER)

1 BNC port: Coax cable (RG59, RG6, RG11) 

1 BNC port: Coax cable (RG59, RG6, RG11) 

1 BNC port: Coax cable (RG59, RG6, RG11) 

Interface: IEEE Side (IP 
Device)

1 RJ45 port; adapter is IEEE 802.3af/at compliant and will 
negotiate power requirements with IP end device. 

(For General/PoE Switch)
1 RJ45 port: supports negotiation with IEEE 802.3 af/at switches

4 RJ45 ports: device must be IEEE 802.3 af/at compliant, 
10/100Mbps connection to IP end device

Power Supply

Maximum 50W (If locally powered and 30W if power provided 
from switch) delivered on 4 pairs.

PoE from standard PoE switch, or external power supply; 
maximum 50W if locally powered. 

PoE from the CLEER switch, or external power supply; maximum 
50W (over 4-pairs) each port

DC IN
(Barrel Connector)

Optional (sold separately)
48V – 56VDC via an external AC/DC Power Adapter (IEC Class II 
isolated only)
NOTE 1: Local power supply used must have its output isolated 
from Earth potential.
NOTE 2: If voltage of local power supply is lower than the power 
voltage provided from the PoE switch, then power on the PoE
switch should be turned off.

Optional (sold separately)
48V – 56VDC via an external AC/DC Power Adapter (IEC Class II 
isolated only)
NOTE 1: Local power supply used must have its output isolated 
from Earth potential.
NOTE 2: If voltage of local power supply is lower than the power 
voltage provided from the PoE switch, then power on the PoE
switch should be turned off.

Optional (sold separately)
48V – 56VDC via an external AC/DC Power Adapter (IEC Class II 
isolated only)
NOTE 1: Local power supply used must have its output isolated 
from Earth potential.
NOTE 2: If voltage of local power supply is lower than the power 
voltage provided from the PoE switch, then power on the PoE
switch should be turned off.

Power Consumption

1.1W

1W 

1W 

Operating Temperature 

-58°F to +158°F (-50°C to +70°C)

Tests conducted against international safety standard at maximum 
ambient temperatures of 60ºC at 30W and 55ºC at 50W

-58°F to +158°F (-50°C to +70°C)

Tests conducted against international safety standard at maximum 
ambient temperatures of 60ºC at 30W and 55ºC at 50W

-58°F to +158°F (-50°C to +70°C)

Tests conducted against international safety standard at maximum 
ambient temperatures of 50ºC 

Mean Time Before 
Failure (MTBF)

20+ years

20+ years

20+ years

Humidity 

10% to 95% (non-condensing) at 35° C

10% to 95% (non-condensing) at 35° C

10% to 95% (non-condensing) at 35° C

Note the following:

All of the above instructions provide basic installation information necessary for the proper and safe functioning of this equipment. Persons installing or 

maintaining this product must read all of the safety instructions and the parts of system grounding, which are applicable to the system being maintained. 

Only trained, qualified service personnel shall install or maintain this product.

• Keep these instructions with the equipment.

• Do not attempt to install or service this equipment unless you are skilled in the installation and maintenance of electronic telecommunications equipment and have

successfully completed specific training for this equipment.

WARNING: FAILURE TO FOLLOW ALL INSTRUCTIONS MAY RESULT IN IMPROPER EQUIPMENT OPERATION AND/OR RISK OF ELECTRICAL SHOCK.

WARNING: ANY CONNECTION TO AN OUTSIDE PLANT LEAD, AN OFF-PREMISE APPLICATION, OR ANY OTHER EXPOSED PLANT APPLICATION MAY 

RESULT IN A FIRE OR SHOCK HAZARD, AND/OR DEFECTIVE OPERATION, AND/OR EQUIPMENT DAMAGE.

Compliance and Environmental Information

All the compliance and environmental information is available on our website www.nvtphybridge.com

EC-Link+ and EC-Base

CAUTION

, Hot surface

ATTENTION

, Surface chaude

VORSICHT

, Heiße Oberfläche

PRECAUCIÓN

, Superficie caliente

VAROITUS

, Kuuma pinta

VOORZICHTIGHEID

, Heet oppervlakte

VARNING

, Varm yta

ADVARSEL

, Varm overflade

ΠΡΟΣΟΧΗ

Καυτή

 

ε

π

ιφάνεια

ATTENZIONE

, Superficie calda

CUIDADO

, Superfície quente

ATTENZJONI

, Wiċċ sħun

ETTEVAATUST

, Kuum pind

VIGYÁZAT

, Forró felület

PREVIDNOST

, Vroča površina

POZOR

, Horký povrch

ATSARGIAI

, Karštas paviršius

UZMANĪBU

, Karstā virsma

POZOR

, Horúci povrch

VARÚÐ

, Heitt yfirborð

PRZESTROGA

, Gorąca powierzchnia

FORSIKTIG

, Varm overflate

PRUDENȚĂ

,

 Suprafata fierbinte

ВНИМАНИЕ

Гореща

 

повърхност

Safety Warnings and Precautions

Refer to the CLEER24 or EC10 Quick Install Guides under “Safety Warnings” for the EC adapters

Reportez-vous aux Quick Install Guides CLEER24 ou EC10 sous “Safety Warnings” pour les adaptateurs EC

Beachten Sie die CLEER24- oder EC10- Quick Install Guides unter “Safety Warnings” für die EC-Adapter

Consulte las Quick Install Guides CLEER24 o EC10 bajo “Safety Warnings” para los adaptadores EC

Katso CLEER24- tai EC10 Quick Install Guides EC-sovittimien “Safety Warnings” alla

Raadpleeg de CLEER24 of EC10 Quick Install Guides onder “Safety Warnings” voor de EC-adapter

Se CLEER24 eller EC10 Quick Install Guides under “Safety Warnings” för EC-adaptrarna

Se CLEER24 eller EC10 Quick Install Guides under "Safety Warnings" for EC-adaptere

Ανατρέξτε

 

στους

 

οδηγούς

 CLEER24 

ή

 EC10 Quick Install Guides 

στην

 

ενότητα

 “Safety Warnings” 

για

 

τους

 π

ροσαρ

μ

ογείς

 EC

Fare riferimento alla sezione CLEER24 o EC10 Quick Install Guides sotto “Safety Warnings” per gli adattatori EC

Consulte o CLEER24 ou EC10 Quick Install Guides em “Safety Warnings” para os adaptadores EC

Irreferi għall-CLEER24 jew EC10 Quick Install Guides taħt “Safety Warnings” għall-adapters EC

Vaadake CLEER24 või EC10 Quick Install Guides alusel “Safety Warnings” EC adapterid

A EC adapterek “Safety Warnings” című részében olvassa el a CLEER24 vagy a EC10 Quick Install Guides című részt

Nanašajo na CLEER24 ali EC10 Quick Install Guides pod "Safety Warnings" za EC adapterji

Další informace naleznete v příručkách CLEER24 nebo EC10 Quick Install Guides v části "Safety Warnings" pro adaptéry EC

Kreiptis į CLEER24 ar EC10 Quick Install Guides pagal "Safety Warnings" Už EC adapteriai

Skatiet CLEER24 vai EC10 Quick Install Guides zem "Safety Warnings,” lai EC adapteri

Pozrite si CLEER24 alebo EC10 Quick Install Guides v časti "Safety Warnings" pre adaptéry EC

Sjá CLEER24 eða EC10 Quick Install Guides undir "Safety Warnings " fyrir EC-millistykki

Zobacz CLEER24 lub EC10 Quick Install  Guides w sekcji "Safety Warnings" w przypadku adapterów EC

Se CLEER24 eller EC10 Quick Install Guides under "Safety Warnings" for EC-adaptere

Consultați ghidurile CLEER24 sau EC10 Quick Install Guides din secțiunea "Safety Warnings" pentru adaptoarele EC

Обърнете

 

се

 

към

 CLEER24 

или

 EC10 Quick Install Guides 

в

 "Safety Warnings" 

за

 

адаптери

 EC

QUICK INSTALL GUIDE

The NVT Phybridge Technical Support Group is available to assist you with product installation, configuration, monitoring and troubleshooting procedures. Should you 

experience trouble with this equipment or for repair or warranty information, please contact NVT Phybridge at +1 905.901.3633 or [email protected].

Technical Support

Warranty: 

The EC adapters are backed by NVT Phybridge’s award-winning customer support and 5-year warranty.

 

Reviews: