background image

NV1023 SDIF-2 Distribution Amplifier                                                                                7 
 

2.     CONFIGURATION AND INSTALLATION 

CAUTION:         IF YOU ARE INSTALLING FR1000 FRAMES AND PS2001 

POWER SUPPLIES IN ADDITION TO NV1023 
DISTRIBUTION AMPLIFIERS AT THIS TIME, YOU 
SHOULD FOLLOW THE SYSTEM-LEVEL 
INSTALLATION PROCEDURES FOUND IN THE NV1000 
TERMINAL EQUIPMENT OPERATIONS INSTRUCTION 
MANUAL (MANUAL PART NO. MI1000-01) LOCATED IN 
THE FRONT OF THIS BINDER. 

CAUTION:         REMOVE POWER FROM THE FRAME IF THE 

INSTALLATION INCLUDES THE CONNECTOR 
BACKPLANE. 

1.          Replace the blank cover plates on the rear of the intended slot in 
the NV1000 frame with the backplane assembly for the NV1023 
distribution amplifier. The FR1000 frame is supplied with a 2.5 mm 
Allen wrench for this purpose. Ensure proper alignment of the active 
module to the backplane with the following procedure: 

a.    Install the EM0104 backplane with the screws loose. 

b.    Plug the active module into the loose backplane. 

c.    With the active module inserted, tighten the screws securing the 

backplane. 

d.    Remove the module and reinsert it to make sure it is properly 

aligned with the backplane and the card guides in the frame. If 
the alignment is not good, repeat the above procedure. When a 
satisfactory fit is obtained, remove the module and continue 
with the installation. 

2.    Make cable connections to the rear panel per the drawings included 

in the Applications section (See Section 1.2). 

3.    Set the input termination jumper on the active module as required 

by the application. Refer to Table 2 - NV1023 Jumper Setting and 
the Component Location drawing in Section 6 for information on 
the jumper location and setting. 

4.   Apply AC line power to the frame and insert the PS2001 power 

supply if it is not already in place. 

5.    Insert the active module with power applied to the frame. 

Summary of Contents for NV1023

Page 1: ...N 2 CONFIGURATION AND INSTALLATION 3 OPERATION 4 FUNCTIONAL DESCRIPTION 5 MAINTENANCE AND TROUBLESHOOTING 6 DRAWINGS AND SCHEMATICS 7 APPENDICES AND CHANGE INFORMATION Nvision NV1023 Instruction Manua...

Page 2: ...le for 75 ohms or high impedance Level TTL Data Rate SDIF 2 Word Clock 28 kHz 54 kHz typical Outputs Number 4 Impedance Low Level TTL Mechanical Size 90 mm x 25 mm x 370 mm 3 1 2 x 1 x 14 1 2 Power So...

Page 3: ...n the rear of any of the 12 active module slots in an NV1000 terminal equipment frame Assembly FR1000 provides the connection interface for external signal cables Figure 1 illustrates the NV1023 inter...

Page 4: ...d at the far end with 75 ohms Connections within the daisy chain must loop through equipment that has low input return loss and whose input impedances are high relative to the cable s characteristic i...

Page 5: ...e Termination High Impedance Termination NV102x Distribution Amplifiers x3 Figure 2 Poor Signal Loop Through Methodology 50 meters 150 feet 0 5 meters 1 5 feet 0 5 meters 1 5 feet SDIF 2 Source High I...

Page 6: ...ance 3 4 Configures NV1023 for high input Z for loop through applications SDIF 2 Source Figure 4 Increasing Signal Fan Out Capability Using Multiple DAs To additional DAs 6 8 total with cable terminat...

Page 7: ...the following procedure a Install the EM0104 backplane with the screws loose b Plug the active module into the loose backplane c With the active module inserted tighten the screws securing the backpl...

Page 8: ...age Jumper J1 provides a means for selecting the input termination resistance 75 ohms for terminating coaxial cables or high impedance for loop through applications Resistor R5 and voltage reference d...

Page 9: ...ing steps will help isolate or eliminate it 1 Assure normal NV1000 system power distribution as follows a Observe the green LED on the PS2001 power supply module If illuminated the line side of the su...

Page 10: ...are not present find the faulty component or connection and replace or repair it d If the proper voltages are present on the module trace the digital audio signal through the module using an oscillos...

Page 11: ...that pertain to the NV1023 SDIF 2 Distribution Amplifier are located here Additional system information may be found in the Appendix at the rear of the NV1000 Operations Manual Reviewing these materi...

Page 12: ...12 NV1023 SDIF 2 Distribution Amplifier...