background image

Exported on Sep/19/2022 02:25 PM

 

 

 

 

 

 

 

NVIDIA Spectrum SN2000 1U Switch Systems 

Hardware User Manual

10/25/40/50/100GbE Open Ethernet Switch Systems Models: SN2700, SN2740, SN2410, 

SN2201, SN2100, SN2010

 

Summary of Contents for SN2010

Page 1: ...Exported on Sep 19 2022 02 25 PM NVIDIA Spectrum SN2000 1U Switch Systems Hardware User Manual 10 25 40 50 100GbE Open Ethernet Switch Systems Models SN2700 SN2740 SN2410 SN2201 SN2100 SN2010...

Page 2: ...gs 16 Air Flow 17 Package Contents 18 System Mounting Options 19 SN2700 Static Rail Kit 19 Removing the System from the Rack 23 SN2700 Telescopic Rail Kit 24 Removing the System from the Rack 27 SN274...

Page 3: ...ED Notifications 60 System Status LEDs 61 Fan Status LEDs 62 Power Supply Status LEDs 63 Unit Identification LED 65 Bad Port LED 65 Port LEDs 66 Inventory Information 68 Software Management 71 Upgradi...

Page 4: ...nitions 81 Interface Specifications 82 QSFP28 Pin Description 82 SFP28 Pin Description 84 RJ 45 CONSOLE and I C Interface 85 RJ45 to DB9 Harness Pinout 86 RJ45 to RJ45 Harness 86 Disassembly and Dispo...

Page 5: ...networking ethernet switching onyx 2 Cumulus Linux User Guide This document contains information regarding the configuration and management of the Cumulus Linux software See https docs nvidia com netw...

Page 6: ...6 CPU Short depth Reverse airflow Rail Kit RoHS6 920 9N101 00F7 1C1 MSN2700 CSBFC Mellanox Spectrum based 100GbE 1U Open Ethernet Switch with Cumulus Linux 32 QSFP28 ports 2 Power Supplies DC x86 CPU...

Page 7: ...bE 100GbE 1U Open Ethernet switch with ONIE 48 SFP28 ports and 8 QSFP28 ports 2 power supplies AC x86 CPU short depth C2P airflow Rail Kit 920 9N112 00R7 0C3 MSN2410 BB2RC NVIDIA Spectrum based 10GbE...

Page 8: ...short depth C2P airflow Rail Kit must be purchased separately 920 9N100 00F7 0 X0 MSN2100 CB2F NVIDIA Spectrum based 100GbE 1U Open Ethernet Switch with NVIDIA Onyx MLNX OS 16 QSFP28 ports 2 AC PSUs...

Page 9: ...with NVIDIA Onyx 18 SFP28 ports and 4 QSFP28 ports 2 Power Supplies AC short depth x86 quad core C2P airflow Rail Kit must be purchased separately 920 9N110 00R7 0 C2 MSN2010 CB2RC Spectrum based 25G...

Page 10: ...r Marketing Description 920 9N110 00R1 0 N1 MSN2201 CB2RO Nvidia Spectrum based 1GBase T 100GbE 1U Open Ethernet switch with ONIE 48 RJ45 ports and 4 QSFP28 ports Dual Power Supply AC x86 CPU short de...

Page 11: ...bles a fully certified and interoperable design speeds up time to service and RoI The systems introduce hardware capabilities for multiple tunneling protocols that enable increased reachability and sc...

Page 12: ...12 SN2700 SN2740 SN2410 SN2100 SN2010 Rear View...

Page 13: ...13 SN2700 and SN2410 SN2740 SN2100 SN2010 SN2201 SN2201 Speed and Switching Capabilities The table below describes maximum throughput and interface speed per system model...

Page 14: ...n using QSFP to 2xQSFP splitter cables 1 7Tb s SN2201 48 4 16 using QSFP to SFP splitter cables 4 or 8 50GbE interfaces when using QSFP to 2xQSFP splitter cables 448Gb s Requiring a 1GBT SFP module Re...

Page 15: ...uct brief Go to https www nvidia com en us networking In the main menu click on Products Ethernet Switch Systems and select the desired product page Certifications The list of certifications such as E...

Page 16: ...ng Options 5 Power on the system Initial Power On 6 Perform system bring up System Bring Up 7 Optional FRU replacements FRU Replacements Safety Warnings Prior to the installation please review the Saf...

Page 17: ...wer inlet side Air Flow Direction Marking Connector Side Inlet to Power Side Outlet The table below provides an air flow color legend and respective OPN designation The following information does not...

Page 18: ...s have been sent Check the parts for visible damage that may have occurred during shipping The SN2700 and SN2410 package content is as follows 1 System 1 Rail kit 1 Power cable for each power supply u...

Page 19: ...SN2700 Static Rail Kit Part Number Legacy Part Number Rack Size and Rack Depth Range 930 9BRKT 00JC 000 MTEF KIT A Short 17 24 or Standard 24 34 The following parts are included in the static rail ki...

Page 20: ...ur installation selection It is important to keep the airflow within the rack in the same direction Note that the part of the system to which you choose to attach the rails the front panel direction a...

Page 21: ...itch by gently pushing the switch chassis pins through the slider key holes until locking occurs Secure the chassis in the rails by screwing 2 flat head Phillips screws E in the designated points with...

Page 22: ...2 flat head Phillips screws E in the designated points with a torque of 1 5 0 2 Nm Attaching the Brackets to the Chassis Install 8 cage nuts in the desired slots of the rack 4 cage nuts in the non ext...

Page 23: ...the rack Do not tighten the screws yet Sliding the Blades in the Rails Secure the system in the rack by tightening the 8 screws inserted in Step 5 and Step 6 with a torque of 4 5 0 5 Nm Removing the...

Page 24: ...ndard 24 34 61 to 86 3 cm The following parts are included in the rail kit package see figure below 1x Right inner rail A 2x Outer rails C Bundled 1x Left inner rail B 2x Outer rails D Bundled 10x M6...

Page 25: ...h Rails Separation Before mounting the system to the rack select the way you wish to place the system Pay attention to the airflow within the rack cooling connector and cabling options While planning...

Page 26: ...10 cage nuts into the desired slots of the rack 4 cage nuts in the non extractable side and 6 cage nuts in the extractable side Installing the Cage Nuts Mount both of the outer rails C D into the rack...

Page 27: ...y inserted fix the switch by closing the remaining 2 screws in the middle and tightening the 8 screws inserted in Step 2 with a torque of 4 5 0 5 Nm Removing the System from the Rack To remove a unit...

Page 28: ...930 9NRKT 00JV 000 MTEF KIT SP Standard 23 6 31 5 60 to 80 cm The following parts are included in the static rail kit see figure below 2x Rack mount rails A 2x Rack mount blades B 8x M6 Standard cage...

Page 29: ...Note that the part of the system to which you choose to attach the rails the front panel direction as demonstrated in Option 1 or the FRUs direction as demonstrated in Option 2 will determine the sys...

Page 30: ...rews use a torque of 1 5 0 2 Nm Attaching the Rails to the Chassis Install 8 cage nuts C in the desired slots of the rack 4 cage nuts in the non extractable side and 4 cage nuts in the extractable sid...

Page 31: ...epth Use four M6 screws D to fix the blades into the rack Do not tighten the screws yet Sliding the Blades in the Rails Secure the system in the rack by tightening the 8 screws inserted in Step 3 and...

Page 32: ...ils to install 2 systems C 2 blank installed covers D 30 flat head 4 40 screws the kit contains enough screws to install 2 systems E 2 frame rail slides F 10 2 spare units M6 pan head screws G 10 2 sp...

Page 33: ...dedicated inlets in the system s rear panel Carefully position the SE single ended cables one on top of the other and use three cable ties to pair them together shown in figure Coupling the Cables wit...

Page 34: ...rews The recommended torque is 0 49 0 54 Nm Attach the Blades to the System Attached Rail with Threaded Cables Top View Slide the two frame slides into the dedicated rails in the metal frame Sliding t...

Page 35: ...nuts in the rear part of each cabinet post Installing the Cage Nuts Attach the frame to the rack by using ten spacer cage nuts and screw ten M6 pan head screws four in the front part of the rack and...

Page 36: ...00JI 000 MTEF KIT E Rack installation static kit for SN2100 SN2010 systems short depth 1U half width switches allows installation of a single switch into standard depth racks The following parts are...

Page 37: ...ystem s sides using 8 flat head 4 40 screws A in each side Attaching the Brackets to the System s Sides Install 8 cage nuts of the relevant type square or round holes according to your rack type Insta...

Page 38: ...ackets to the rack s posts by inserting four M6 screws and washers C D E in the designated cage nuts 2 in each side Tighten all screws Attaching the Brackets to the Rack SN2201 Tool Less Rail Kit Tool...

Page 39: ...irflow will affect the heat dissipation The part of the system to which you choose to attach the rails will determine the system s adjustable side The system s part to which the brackets are attached...

Page 40: ...nner rails should be assembled to the switch using the first five holes from its front side Recessed Installation The inner rails should be assembled to the switch skipping the first hole from its fro...

Page 41: ...er rails B C in the rack as shown in the following illustration Mount the chassis onto the rack Insert the chassis into the middle outer rails installed in the rack C Secure the chassis in place by ti...

Page 42: ...T 00JR 000 MTEF KIT M NVIDIA fixed installation kit 2 post rack for SN2201 switch The following parts are included in the 2 post mounting rail kit see figure below 2x Rack mount brackets A 12x M4 scre...

Page 43: ...B 4xC 4xD Attach the two brackets A to the chassis using the 12 M4 screws B provided in the kit Install 4 cage nuts C in the desired 1U slots of the rack Mount the device in the rack using 10 32 rack...

Page 44: ...onnector is firmly seated The LED indicator corresponding to each data port will light when the physical connection is established When a logical connection is made the relevant port LED will turn on...

Page 45: ...r to Port LEDs QSFP Cable Orientation SN2010 SFP Cable Orientation SN2740 Cable Orientation Do not force the cable into the cage with more than 40 newtons 9 0 pounds 4kg force Greater insertion force...

Page 46: ...When using this feature you should log into the NVIDIA Onyx MLNX OS CLI and configure the individual ports to be split 2 or split 4 For further information on NVIDIA s cable visit http www mellanox c...

Page 47: ...rked in green are splittable to 4 SFP28 ports each The bottom QSFP28 ports gray are blocked when the upper ports are in split mode All QSFP28 ports can be split to 2 QSFP28 ports SN2410 Splitting Opti...

Page 48: ...blocking requirements SN2010 Splitting Options All QSFP28 ports are splittable Each port can be split into 4xSFP28 10 25G or 2xQSFP28 50G ports There are no blocking requirements SN2201 Splitting Opt...

Page 49: ...SU System Status LEDs each The Bad Port LED exists in SN2700 and SN2410 only Two Power Inlets Electric Caution Notifications The system platform will automatically power on when AC power is applied Th...

Page 50: ...m using the supplied harness cable DB9 to RJ45 Make sure to connect to the Console RJ45 port and not to the Ethernet MGT port Step 2 Configure a serial terminal program for example HyperTerminal minic...

Page 51: ...tep to obtain an IP address for the system mgmt0 is the management port of the system If you wish the DHCP server to assign the IP address type yes and press Enter If you type no no DHCP then you will...

Page 52: ...yes Step 1 Hostname Step 2 Use DHCP on mgmt0 interface yes no Step 3 Use zeroconf on mgmt0 interface no Step 4 Primary IP address for example 192 168 10 4 10 10 10 10 Mask length may not be zero if a...

Page 53: ...test version that can be retrieved from NVIDIA support site To upgrade software please refer to the NVIDIA Onyx MLNX OS User Manual Disable Dynamic Host Configuration Protocol DHCP DHCP is used for au...

Page 54: ...ollow the instructions on the SSH for Remote Access page in the Cumulus Linux User Guide FRU Replacements Power Supply NVIDIA systems that are equipped with two replaceable power supply units work in...

Page 55: ...ch will snap into place confirming the proper installation Insert the power cord into the supply connector Insert the other end of the power cord into an outlet of the correct voltage Fans The system...

Page 56: ...sure the mating connector of the new unit is free of any dirt and or obstacles Insert the fan unit by sliding it into the opening until slight resistance is felt Continue pressing the fan unit until...

Page 57: ...ng through NVIDIA QSFP28 to SFP28 Dynamix QSA adapters hybrid or split cables The systems offer support of up to 3 5W transceivers in all QSFP28 ports and support of up to 1 5W in all SFP28 ports Some...

Page 58: ...orts 3 6 9 12 15 18 can be used Up to 2m any DAC 10GbE cables all ports can be used 0 5m to 5m any DAC For connections with other switches AOCs Transceivers only Supported 25GbE and 40 100GbE Cables o...

Page 59: ...MLNX OS to view the full procedure USB The USB interface is USB 2 0 mini USB in SN2100 compliant USB 1 0 is not supported and can be used by NVIDIA Onyx MLNX OS software to connect to an external disk...

Page 60: ...hout a password and set a new password for the user admin For Cumulus Linux password reset instructions please refer to the Single User Mode Boot Recovery section in the Cumulus Linux User Guide Statu...

Page 61: ...Ds front and back if exist supply identical information System Status LEDs Front and Rear Sides LED Type System Front Rear System Status LEDs SN2700 Yes Yes SN2740 Yes No SN2410 Yes Yes SN2100 Yes No...

Page 62: ...tatus is reflected by the LEDs only once the Network Operating System boot is complete Fan Status Front LED Assignments LED Behavior Description Action Required Solid Green All fans are up and running...

Page 63: ...t hot swap ability Each power supply unit has a single 2 color LED on the right side of the unit that indicates the status of the unit SN2700 and SN2410 Rear Side Panel SN2740 Rear Side Panel Risk of...

Page 64: ...id Red PSU is faulty or disconnected Make sure the AC cable is plugged in and active If the problem resumes the PSU might be faulty Off PSU not present N A The power supply status LEDs on the rear sid...

Page 65: ...rify the LED status run switch config show leds Module LED Status MGMT UID Blues To deactivate the UID LED on a switch system run switch config led MGMT uid off Bad Port LED The Bad Port LED indicator...

Page 66: ...66 Port LEDs System Port LEDs SN2700 SN2740 SN2410 QSFP28 SFP28 SN2010 QSFP SFP...

Page 67: ...plit to four it adjacent port is canceled If the ports run at a 100GbE 40GbE speed each the two lower LEDs 2 and 4 will light green If the ports run at a 50GbE speed each the left LEDs 1 and 2 will li...

Page 68: ...ble integrity Solid Yellow Link is up N A Solid Green Link is up with no traffic N A Flashing Green Link is up with traffic N A Inventory Information The system s inventory parameters such as Serial N...

Page 69: ...69 SN2410 Inventory Information Illustration SN2100 Pull out Tab SN2010 Pull out Tab...

Page 70: ...70 SN2201 Pull out Tab...

Page 71: ...If you do not have the latest revision upgrade your software using the CLI or the GUI Copy the updated software to a known location on a remote server within the user s LAN For further information ple...

Page 72: ...d Cause Possible PSU issue Solution Check replace the Replace the PSU if System boot failure while using NVIDIA Onyx MLNX OS Software upgrade failed on x86 based systems Solution Connect the RS232 Pus...

Page 73: ...set to the default configuration following an AC power loss Cause Date and time are reconfi Solution To set the system s clock set hh mm To verify the config show clock It is recommended that run enab...

Page 74: ...10 90 non condensing Altitude 3050m Noise level 71 6 dB A Regulatory Safety EMC CB cTUVus CE CU S_Mark CE FCC VCCI ICES RCM BSMI KCC CCC RoHS RoHS complaint Power Supply AC and DC Input Voltage 1x 2x...

Page 75: ...ulatory Safety EMC CB cTUVus CE CU S_Mark CE FCC VCCI ICES RCM BSMI KCC CCC RoHS RoHS complaint Power Input Voltage 1x 2x 100 127VAC 50 60Hz 4 5A 200 240 50 60Hz 2 9A 40 5 60VDC 12A 192 288VDC not cer...

Page 76: ...1x 2x 100 127VAC 50 60Hz 4 5A 200 240 50 60Hz 2 9A 40 5 60VDC 12A 192 288VDC not certified 48VDC Input voltage range 40 to 72 VDC Global Power Consumption 40GbE 100GbE Models Typical power with passi...

Page 77: ...Hz Quad Core PCIe 4x Gen2 0 Switch NVIDIA Spectrum Memory SDRAM 8GB DDR3L 1600 MT s SO DIMM Storage 16GB Dual Channel MLC M 2 SATA SSD Throughput 3 2Tb s SN2010 Series Feature Value Mechanical Size 43...

Page 78: ...ght 7 410kg Speed 1 10 25 40 50 56 100GbE per QSFP28 port 10 100 1000Mbase T per RJ45 port Connector cage 48 RJ45 ports of 1GbE and 4 QSFP28 ports of 100GbE Environmental Temperature Operational 0 to...

Page 79: ...79 Feature Value Memory SDRAM 8GB ECC DDR4 SO DIMM Storage 20GB SSD M 2 PCIe Gen 3 Throughput 448GB s...

Page 80: ...00J V 000 MTEF KIT SP Rack installation kit for 1U wide systems to be mounted into standard depth racks SN2410 SN2740 Included in the SN2410 and SN2740 packages 930 9NRKT 00J G 000 MTEF KIT D Rack in...

Page 81: ...eshold definitions are measured by the Spectrum ASICs and impact the overall switch system operation state as follows Warning 105 C On managed systems only When the ASIC device crosses the 100 C thres...

Page 82: ...nd 2 Tx2n Connected to Port 2 lane Rx Inverted Data 3 Tx2p Connected to Port 2 lane Rx Non Inverted Data 4 GND Ground 5 Tx4n Connected to Port 4 lane Rx Inverted Data 6 Tx4p Connected to Port 4 lane R...

Page 83: ...Port 2 lane Tx Inverted Data 22 Rx2p Connected to Port 2 lane Tx Non Inverted Data 23 GND Ground 24 Rx4n Connected to Port 4 lane Tx Inverted Data 25 Rx4p Connected to Port 4 lane Tx Non Inverted Data...

Page 84: ...dule Transmitter Fault a 3 TX_Disable Transmitter Disable Turns off transmitter laser output b 4 SDA 2 wire Serial Interface Data Line c 5 SCL 2 wire Serial Interface Clock Line d 6 MOD_ABS Module Abs...

Page 85: ...transmitter fault caused by either the TX bias current or the TX output power exceeding the preset alarm thresholds A low output indicates normal operation In the low state the output is pulled to 0 8...

Page 86: ...kage to connect a host PC to the system s Console RJ45 port RJ45 to DB9 Harness Pinout RJ45 to RJ45 Harness 2m RJ45 to RJ45 serial port cable is provided in the SN2410 and SN2700 packages The harness...

Page 87: ...uts Disposal According to the WEEE Directive 2002 96 EC all waste electrical and electronic equipment EEE should be collected separately and not disposed of with regular household waste Dispose of thi...

Page 88: ...88...

Page 89: ...ifications November 23 2021 3 4 Updated Global Power Consumption in Specifications June 10 2021 3 3 Updated Ordering Information November 29 2020 3 2 Updated Accessory and Replacement Parts May 26 202...

Page 90: ...October 2017 1 9 Added SN2740 Updated Installation Kit System Installation and Initialization SN2410 Splitting Options February 2017 1 8 Updated Unit Identification LED 1 7 Updated Data Interfaces Spe...

Page 91: ...ss A Statement in Safety Warnings Updated Introduction to Mellanox SN2000 Spectrum Ethernet Switch Systems Software Management Troubleshooting Instructions Specifications Accessory and Replacement Par...

Page 92: ...by customer and perform the necessary testing for the application in order to avoid a default of the application or the product Weaknesses in customer s product designs may affect the quality and rel...

Page 93: ...of the respective companies with which they are associated Copyright 2022 NVIDIA Corporation affiliates All Rights Reserved...

Reviews: