45
2.
3.
Image type: FS3
FW Version: 10.10.3000
FW Release Date: 29.4.2014
Description: UID GuidsNumber Step
Base GUID1: 00002c123456abcd 8 1
Orig Base GUID1: 0002c903002ef500 8 1
Base GUID2: 00002c123456abd5 8 1
Orig Base GUID2: 0002c903002ef508 8 1
Base MAC1: 00002c56abcd 8 1
Orig Base MAC1: 0002c92ef500 8 1
Base MAC2: 00002c56abd5 8 1
Orig Base MAC2: 0002c92ef508 8 1
Image VSD:
Device VSD: VSD
PSID: MT_1240110019
Change GUIDS for device (specifying guids_num and step_size):
# mstflint -d 41:00.0 q
Image type: FS3
FW Version: 10.10.3000
FW Release Date: 29.4.2014
Description: UID GuidsNumber Step
Base GUID1: 0002c903002ef500 8 1
Base GUID2: 0002c903002ef508 8 1
Base MAC1: 0002c92ef500 8 1
Base MAC2: 0002c92ef508 8 1
Image VSD:
Device VSD: VSD
PSID: MT_1240110019
# mstflint -d 41:00.0 -uid 0000000000000001 -ocr sg guids_num=2 step_size=1
-W- Firmware flash cache access is enabled. Running in this mode may cause the firmware to hang.
Updating GUID section - OK
Updating ITOC section - OK
Restoring signature - OK
# mstflint -d 41:00.0 q
Image type: FS3
FW Version: 10.10.3000
FW Release Date: 29.4.2014
Description: UID GuidsNumber Step
Base GUID1: 0000000000000001 2 1
Orig Base GUID1: 0002c903002ef500 8 1
Base GUID2: 0000000000000003 2 1
Orig Base GUID2: 0002c903002ef508 8 1
Base MAC1: 000000000001 2 1
Orig Base MAC1: 0002c92ef500 8 1
Base MAC2: 000000000003 2 1
Orig Base MAC2: 0002c92ef508 8 1
Image VSD:
Device VSD: VSD
PSID: MT_1240110019
Change GUIDs for image:
# mstflint -i /tmp/connect-ib.bin q
Image type: FS3
FW Version: 10.10.3000
FW Release Date: 29.4.2014
Description: UID GuidsNumber Step
Base GUID1: 0002c903002ef500 8 1
Base GUID2: 0002c903002ef508 8 1
Base MAC1: 0002c92ef500 8 1
Base MAC2: 0002c92ef508 8 1
Image VSD:
Device VSD: VSD
PSID: MT_1240110019
# mstflint -i /tmp/connect-ib.bin -uid 000123456abcd sg
Orig Base GUID/MAC refers to the GUIDs/MACs located in the MFG(manufacture
guids) section of the flash/image.