Device: 0000:35:00.0
LINK_TYPE_P1 ETH (1)
Device #6:
Device type: ConnectX5
Device: 0000:5d:00.0
LINK_TYPE_P1 ETH (1)
Device #7:
Device type: ConnectX5
Device: 0000:e6:00.0
LINK_TYPE_P1 ETH (1)
Device #8:
Device type: ConnectX5
Device: 0000:58:00.0
LINK_TYPE_P1 ETH (1)
Device #9:
Device type: ConnectX5
Device: 0000:86:00.0
LINK_TYPE_P1 ETH(2)
LINK_TYPE_P2 ETH(2)
Starting the Mellanox Software Tools
~$ sudo mlxconfig -y -d /dev/mst/mt4119_pciconf0 set LINK_TYPE_P1=1
~$ sudo mlxconfig -y -d /dev/mst/mt4119_pciconf1 set LINK_TYPE_P1=1
~$ sudo mlxconfig -y -d /dev/mst/mt4119_pciconf2 set LINK_TYPE_P1=1
~$ sudo mlxconfig -y -d /dev/mst/mt4119_pciconf3 set LINK_TYPE_P1=1
~$ sudo mlxconfig -y -d /dev/mst/mt4119_pciconf4 set LINK_TYPE_P1=1
~$ sudo mlxconfig -y -d /dev/mst/mt4119_pciconf5 set LINK_TYPE_P1=1
~$ sudo mlxconfig -y -d /dev/mst/mt4119_pciconf6 set LINK_TYPE_P1=1
~$ sudo mlxconfig -y -d /dev/mst/mt4119_pciconf7 set LINK_TYPE_P1=1
$
sudo mlxconfig query | egrep -e Device\|LINK_TYPE
Device #1:
Device type: ConnectX5
Device: 0000:bd:00.0
LINK_TYPE_P1 IB(1)
Device #2:
Device type: ConnectX5
Summary of Contents for DGX-2 SYSTEM
Page 1: ......
Page 2: ...4 1 4 2...
Page 3: ...7 4 1...
Page 4: ...9 1...
Page 5: ...12 1 12 1 3 12 3 1 12 6 1...
Page 6: ......
Page 7: ...s...
Page 8: ......
Page 9: ...Hardware Overview...
Page 11: ......
Page 13: ......
Page 15: ......
Page 16: ...enp134s0f0 enp134s0f1...
Page 17: ...enp6s0 enp134s0f0 enp134s0f1...
Page 18: ...Mellanox ConnectX 5 Firmware Download...
Page 19: ...enp134s0f0 enp134s0f1...
Page 23: ...DGX 2 Server Front DGX 2 Server Back...
Page 24: ...Configuring Static IP Address for the BMC https bmc ip address...
Page 25: ......
Page 26: ...Network Ports Configuring Static IP Addresses for the Network Ports...
Page 27: ...Connecting to the DGX 2Console...
Page 41: ......
Page 42: ......
Page 43: ......
Page 55: ...sudo nvsm set powermode maxp sudo nvsm show chassis localhost...
Page 57: ...Managing CPU Mitigations cat sys devices system cpu vulnerabilities Mitigation...
Page 60: ...sudo update initramfs u dracut force boot initramfs uname r img uname r sudo reboot...
Page 79: ...nvsm dump health https nvid nvidia com dashboard...
Page 80: ...https bmc ip address...
Page 82: ......
Page 85: ...hpm hpm...
Page 86: ...telinit 1 umount raid sync ipmitool chassis power off...
Page 108: ...sudo nvidia vm health check options...
Page 119: ...NVIDIA DGX 2 Service Manual...
Page 120: ...Creating a Unique BMC Password...
Page 133: ......
Page 134: ......
Page 138: ......
Page 139: ...www dtsc ca gov perchlorate...
Page 147: ...Notice...