nvent Schroff 20836-220 User Manual Download Page 14

VME64x System Subrack 10 U

Product Definition

20836-220

www.schroff.biz

10

R1.0, November 19, 2007

Figure 5: Wiring Diagram

10006805

Summary of Contents for Schroff 20836-220

Page 1: ...VME64x System Subrack 10 U User s Manual Product No 20836 220 Revision R1 0 November 19 2007 Doc No 63972 162...

Page 2: ...anagement System to EN ISO 9001 2000 The company cannot accept any liability for errors or misprints The company reserves the right to amendments of technical specifications due to further development...

Page 3: ...Rear View 5 2 3 Mechanical Overview 6 2 4 Subrack 7 2 5 VME64x Backplane 7 2 6 Power Supply 8 2 6 1 Grounding 8 2 7 Thermals 11 2 8 Fan Control Module FCM 12 2 9 Chassis Monitoring Module CMM optional...

Page 4: ...VME64x System Subrack 10 U 20836 220 www schroff biz II R1 0 November 19 2007...

Page 5: ...there is no valid approval for this unit In order to enable stand alone functionality additional elements are required An operational system is achieved only by way of appropriate VME or VME64x board...

Page 6: ...hazard symbol It indicates that there are dangerous voltages inside the Shelf Caution This is the user caution symbol It indicates a condition where damage of the equipment or injury of the service pe...

Page 7: ...cifications User Manual VME64x Backplanes Order no 73972 103 Short Form User Manual VME64x Backplanes Order no 73972 091 User Manual Fan Control Module FCM Order no 73972 083 User Manual Chassis Monit...

Page 8: ...A 1 1 1997 Backplane with P0 connectors An open frame power supply with wide range input Speed controlled fans for cooling the boards Fan Control Module FCM for fan monitoring controlling Display modu...

Page 9: ...U Product Definition 20836 220 www schroff biz 5 R1 0 November 19 2007 2 2 Rear View Figure 2 Rear View 10006801 10 Air Outlet 13 Fuses 11 Rear Card Cage 14 Mains line switch 12 Power supply drawer 15...

Page 10: ...Mechanical Overview Figure 3 Mechanical Overview 10006802 1 Fan Tray Left 7 Front panel 2 U Fan Tray cover 2 Backplane 11 Rear Card Cage 3 Front Card Cage 12 Drawer with Power Supply 4 Front panel 2 U...

Page 11: ...rails are fitted with ESD clips 2 5 VME64x Backplane The 7 U 6 1 21 slot Backplane with P0 connectors is compliant to VITA 1 1 1997 VITA 38 Systemmanagement for VME For more information see the User...

Page 12: ...the protective earth conductor of the power cable Hazardous voltage Parts of the power supply may be exposed with hazardous voltage Always remove mains line connector before carry out any assembly wo...

Page 13: ...3 Mains line switch 7 Backplane Connector 4 AC connector IEC320 C14 Input voltage nominal 100 240 VAC Mains Frequency 50 60 400 Hz Output max 1000 W Output voltages 3 3 5 0 12 0 12 0 V V V V 60 120 17...

Page 14: ...VME64x System Subrack 10 U Product Definition 20836 220 www schroff biz 10 R1 0 November 19 2007 Figure 5 Wiring Diagram 10006805...

Page 15: ...to the bottom air plenum and turns 90 upward As the air passes across the hot components on the Front Boards heat is carried away by forced convection The air exits the Subrack at the top is drawn int...

Page 16: ...The highest temperature level is the reference for the fan speed If one ore more sensors exceed 60 C the output for the temperature fail LED and a digital output are activated Since the fan speed is t...

Page 17: ...45 connector Ethernet an a D Sub9 connector RS 232 A user interface via HTML page is available The CMM can monitor the 4 VME64x voltages and two additional voltages up to 24 VDC The error status can b...

Page 18: ...Module Figure 8 Display Module The Display Module is located at the lower front side of the subrack 4 green LEDs signal the 4 VME64x voltages two red LEDs signal over temperature and fan fail events...

Page 19: ...r possible If installation in an enclosed rack is unavoidable ensure that the rack has adequate ventilation Maintain ambient airflow to ensure normal operation If the airflow is blocked or restricted...

Page 20: ...onstructed to support the weight and dimensions of the Shelf Install any stabilizers that came with your equipment rack before mounting or servicing the system in the rack Load the rack from the botto...

Page 21: ...ower on the system and determine the actual current consumtion Replace the mains fuses suitable to the actual current Figure 9 Mains Fuses Warning Voltages over 60 VDC can be present in this equipment...

Page 22: ...t designated as a device A CE symbol is therefore not required However the systems comply with all requirements Each individual component complies to the EMC standard 89 336 EWG and to the low frequen...

Page 23: ...p 1 AC mains line module with IEC 320 C14 connector mains fuses and line filter 1 Open Frame power supply 1000 W with wide range input 100 VAC to 240 VAC with 4 voltages 5 V 120 A 3 3 V 60 A 12 V 17 A...

Page 24: ...DC Fans Each 500 m h 295 cfm Ambient Temperature Operating 0 C to 40 C Storage 40 C to 85 C Humidity permissable Humidity 30 to 80 non condensing EMC the system meets the requirements for Emitted Inte...

Page 25: ......

Page 26: ...SCHROFF GMBH www schroff biz Langenalberstr 96 100 Tel 49 0 7082 794 0 Fax 49 0 7082 794 200 D 75334 Straubenhardt...