![nvent RAYCHEM H908 Installation Instructions Manual Download Page 8](http://html.mh-extra.com/html/nvent/raychem-h908/raychem-h908_installation-instructions-manual_1720664008.webp)
8 | nVent.com
Outer jacket
Braid
Bus wires
Conductive core
Inner jacket
Braid
Bus wires
Conductive core
Inner jacket
WinterGard H311 and WinterGard Plus H611
Heating cables with braid and no outer jacket
WinterGard Wet H612
Heating cables with braid and outer jacket
Black and white
power wires
Green ground wire
Plug-in cord
3 in
Note: Instructions generally show heating cable with braid and outer jacket.
Cables with no outer jacket look slightly different from those illustrated.
H908 POWER CONNECTION KIT
Identify heating cable
Stripped end of ground-fault protection device
5 in tube
8 in tube
2-3/4 in
1
2A
For all heating cables
For H311 and H611 heating cables only
• Slide 8-inch tube and 5-inch tube
over end of the plug-in cord.
• Unravel 2 3/4 inches of braid.
• Straighten the braid and twist
into a pigtail.