nVent RAYCHEM FROSTEX Installation Instructions And User Manual Download Page 10

LIMITED WARRANTY

nVent warrants all Frostex self-regulating 

heating cables and components against faulty 

workmanship and use of defective materials 

for two (2) years from the date of purchase. 

This warranty can be amended only by a written 

instrument signed by a duly authorized officer 

of nVent. Buyer’s exclusive remedy under 

this warranty shall be to have nVent, within a 

reasonable time, repair such goods or supply 

replacement goods or credit Buyer’s account for 

such goods and accept their return whichever 

nVent may elect at its sole discretion. nVent shall 

in no event be liable for the cost of removal or 

installation, for loss or damage to or loss of use 

of facilities or other property, loss of revenue, loss 

of use of revenue, loss of anticipated profits, or 

other damages or costs of any kind whatsoever, 

whether direct, indirect, incidental,  

or consequential.
Notwithstanding the foregoing, nVent shall have 

no liability whatsoever unless: (a) Buyer promptly 

notifies nVent in writing after discovery of an 

alleged nonconformity and includes a detailed 

explanation of the alleged nonconformity; (b) 

Buyer promptly returns the goods to nVent 

postage prepaid, at the address obtained by 

calling Customer Service at 1-800-545-6258 or 

650-216-1526; and (c) nVent examination of 

such goods establishes to nVent satisfaction 

that such alleged nonconformities actually exist 

and occurred in the cause of proper and normal 

use and were not caused by accident, misuse, 

neglect, alteration or improper installation, 

repair or testing or such other cause outside of 

the responsibility of nVent under this Limited 

Warranty.
THE FOREGOING WARRANTY IS IN LIEU OF ALL 

OTHER REPRESENTATIONS, WARRANTIES, OR 

CONDITIONS, EXPRESS OR IMPLIED, INCLUDING 

WITHOUT LIMITATION ANY IMPLIED WARRANTY 

OF MERCHANTABILITY, FITNESS FOR A 

PARTICULAR PURPOSE OR NONINFRINGEMENT, 

AND OF ANY OTHER OBLIGATION OR LIABILITY 

ON THE PART OF nVent, WHETHER BY STATUTE, 

CONTRACT, STRICT LIABILITY, TORT OR 

OTHERWISE.
If the goods are a consumer product in buyer’s 

jurisdiction, the above exclusion or limitation of 

incidental or consequential damages and the 

above disclaimer of implied warranties may not 

apply. The term of any such implied warranty 

is limited to the term of this two-year Limited 

Warranty. Some jurisdictions do not allow 

limitations on how long an implied warranty 

lasts, so the above limitation may not apply. This 

warranty gives consumers specific legal rights, 

and consumers may also have other rights, which 

vary by jurisdiction.

©2018 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates. All other trademarks are the property of their 
respective owners. nVent reserves the right to change specifications without notice.

Raychem-IM-H56581-FrostexFreezeProtection-EN-1805 

PN 791791-000

nVent.com

North America 

Tel +1.800.545.6258

Fax +1.800.527.5703

[email protected]

Europe, Middle East, Africa

Tel +32.16.213.511

Fax +32.16.213.604

[email protected]

Asia Pacific

Tel +86.21.2412.1688

Fax +86.21.5426.3167

[email protected]

Latin America

Tel +1.713.868.4800

Fax +1.713.868.2333

[email protected]

Summary of Contents for FROSTEX

Page 1: ...from freezing nVent RAYCHEM Frostex Pipe Freeze Protection System Using the 9800 FlexFit Plug Kit Installation Instructions and User Guide APPROVALS G 60J9 Residential and Mobile Home Pipe Heating Cab...

Page 2: ...cm plastic cable ties not included may be used to secure ground fault unit to pipe insulation If you have any questions after reading this guide call this toll free nVent number 800 545 6258 Save this...

Page 3: ...ssemble at temperatures below 0 F 18 C The Frostex system can be left plugged in all year however you will save energy by unplugging the system when there is no risk of freezing Use a properly grounde...

Page 4: ...s by your pipe length Add one extra foot 30 cm for each valve in your line Add one extra foot 30 cm for the distance to the power connection For installations in a crock add an additional 2 feet 60 cm...

Page 5: ...the heating cable 2B Push the braid back Push the braid back 1 in 25 mm from heating cable end 1 in 25 mm 2C Remove the plastic wrap Cut and remove the clear plastic wrap Do not cut into the blue jack...

Page 6: ...t sticking up Note The clear plastic wrap does not need to be removed 3B Insert the cable Insert the heating cable all the way into the cable guide until the cable hits the back wall Be sure no braid...

Page 7: ...ostex 9610 application tape 1 foot spacing Figure 3 Single run method Multiple run method When two or more runs are required install the heating cable in the 4 o clock and 8 o clock positions as shown...

Page 8: ...Step 6 Start up the system 6A Plug in the heating cable After installing the heating cable and insulation remove the clear label that covers the test and reset buttons Then plug the 9800 FlexFit plug...

Page 9: ...can be removed Reinstall the screws completely into the heating cable guide before re attaching Repeat installation steps 3A 3D ensuring no braid strands enter the heating cable guide during Step 3B R...

Page 10: ...glect alteration or improper installation repair or testing or such other cause outside of the responsibility of nVent under this Limited Warranty THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER REPRES...

Reviews: