background image

NuPow

er Xtender™ 

12B04A-D27 User Manual 

 

 

 

Rev 1.0 

 

4.2

 

DC POWER 

The  nominal  supply  voltage  for  the  NuPower  Xtender  is  +28  VDC.  The  amplifier  module  is  able  to 
support  operation  over  a  supply  voltage  range  of  +11  to  +32  VDC  with  minimal  performance 
degradation. 

4.3

 

GROUND 

The signal and power grounds are tied together in the amplifier module. 

4.4

 

RS-485 SERIAL COMMUNICATIONS 

These  signals  are  for  the  RS-485  serial  communications  with  the  NuPower  Xtender.  This  interface  is 
described in Section 5. 

4.5

 

TRANSMIT/RECEIVE (T/R) SOURCE OR SINK 

The T/R Source or Sink line is configurable as either an output (source) or an input (sink). When the T/R 
line  is  configured  in  source  mode,  the  Xtender  transmit  and  receive  switching  occurs  automatically, 
based on the T/R level setting 

and the transceiver’s transmit state

. The Xtender sources a logic signal to 

indicate  the  mode  (transmit  or  receive)  of  the  BDA.  A  logic 

high

  indicates  the  Xtender  is  in  transmit 

mode, while a logic 

low

 indicates the Xtender is in receive mode. 

When  the  T/R  line  is  configured  in  sink  mode,  the  transmit  and  receive  switching  is  under  manual 
control. Applying a logic 

high

 to the T/R line places the Xtender in transmit mode. Likewise, applying a 

logic 

low

 to the T/R line places the Xtender in receive mode.  

T/R line levels can be configured to +3.3 VDC or +5 VDC logic levels.  
This I/O line is described in Section 5. 

 

 

Summary of Contents for NUPOWER XTENDER 12B04A-D27

Page 1: ...ER XTENDER 12B04A D27 BIDIRECTIONAL L S BAND AMPLIFIER PART NUMBER NW BA 12B04A D27 NuWaves Engineering 132 Edison Drive Middletown Ohio 45044 PH 513 360 0800 FAX 513 539 8782 www nuwaves com product...

Page 2: ...porated into the chassis Completely Characterized The NuPower Xtender family of solid state bidirectional amplifiers has been completely characterized over temperature voltage and frequency These high...

Page 3: ...in transmit mode The integrated low noise amplifier provides a minimum of 13 dB of gain in receive mode Based on the latest Gallium Nitride GaN technology NuPower s high efficiency and 6 9 in 3 form f...

Page 4: ...ansmit RF Gain 15 dB typ Nominal Input Drive Level 27 dBm Maximum Input Drive Level 30 dBm Receive RF Gain 13 dB min Receive Noise Figure 3 5 dB typ T R Mode Automatic Sensing or Manual T R Line T R S...

Page 5: ...ONS Figure 2 NuPower Xtender 12B04A D27 Mechanical Outline Table 3 NuPower Xtender 12B04A D27 Mechanical Specifications Parameter Specification RF Connectors SMA female Control Power Interface Connect...

Page 6: ...ratures may require additional heat sinking to maintain a baseplate temperature below 60 C at 100 transmit duty cycle Figure 3 The NuPower PA Kit offers out of the box operation for the user The fan c...

Page 7: ...Directly connecting to an antenna specified for the frequency range 1 0 to 2 5 GHz Connecting to an inappropriate antenna may result in damage to the amplifier module Connecting to a proper antenna th...

Page 8: ...into 50 otherwise the amplifier could be damaged 4 1 INTERFACE CONNECTOR The NuPower Xtender features a 9 pin Micro D interface connector for control power and ground connections Table 4 NuPower Xten...

Page 9: ...r an output source or an input sink When the T R line is configured in source mode the Xtender transmit and receive switching occurs automatically based on the T R level setting and the transceiver s...

Page 10: ...always ignored After receiving and processing a command the NuPower Xtender sends a Carriage Return terminated string as a notification that the command was completed 5 1 SERIAL COMMANDS Serial comman...

Page 11: ...recommended to set a lower transmit threshold control value The STAT command can be used to display the current Transmit Threshold Control value The TRLVLxxxx command is used to change the setting of...

Page 12: ...s controlled by applying a logic high or logic low to this line Applying a logic high signal to this line enables transmit mode while applying a logic low enables receive mode Note Factory default set...

Page 13: ...disposing of a NuWaves product Do not remove the cover or any hardware Do not remove components from the circuit card assembly Do not incinerate Do not crush or shred Do not dispose of as unsorted mun...

Page 14: ...and Sales Phone 513 360 0800 Email product sales nuwaves com NuWaves Home Page https www nuwaves com Product Warranty https products nuwaves com wp content uploads NuWaves_Warranty_Repair pdf 7 1 GENE...