background image

NuPower

TM

 

L60T01

 

User

 

Manual

    

 

 

 

Rev

 

1.1

 

9

 

 

4.3

 

GROUND 

The

 

signal

 

and

 

power

 

grounds

 

are

 

tied

 

together

 

in

 

the

 

PA

 

module.

  

4.4

 

RF ENABLE 

This

 

signal

 

is

 

the

 

logic

 

control

 

input

 

that

 

designates

 

whether

 

the

 

unit

 

is

 

in

 

transmit

 

or

 

standby

 

mode.

 

The

 

RF

 

Enable

 

line

 

is

 

pulled

 

high

 

internally

 

placing

 

the

 

PA

 

module

 

in

 

standby

 

mode.

 

If

 

the

 

pin

 

is

 

left

 

floating

 

(i.e.

 

not

 

connected),

 

the

 

unit

 

will

 

default

 

to

 

standby

 

mode.

 

Grounding

 

the

 

pin

 

(i.e.

 

a

 

voltage

 

below

 

+0.2

 

VDC)

 

places

 

the

 

unit

 

in

 

transmit

 

mode.

 

The

 

user

 

can

 

either

 

connect

 

the

 

RF

 

Enable

 

line

 

to

 

pins

 

1,

 

2,

 

6

 

&

 

8

 

on

 

the

 

CTRL/PWR

 

interface

 

connector,

 

or

 

an

 

open

 

drain

 

logic

 

line

 

capable

 

of

 

sinking

 

500

 

µ

A

 

to

 

place

 

the

 

unit

 

in

 

transmit

 

mode.

 

4.5

 

TEMP FLAG 

This

 

signal

 

is

 

an

 

output

 

to

 

indicate

 

an

 

over

temperature

 

condition

 

in

 

the

 

NuPower

 

L60T01.

 

A

 

logic

 

high

 

(+5

 

VDC)

 

indicates

 

normal

 

operation,

 

while

 

a

 

logic

 

low

 

(0

 

VDC)

 

indicates

 

an

 

over

temperature

 

condition.

 

The

 

NuPower

 

L60T01

 

incorporates

 

internal

 

logic

 

circuitry

 

that

 

turns

 

off

 

the

 

DC

 

bias

 

to

 

the

 

RF

 

transistors.

  

 

Caution:

 

The

 

amplifier

 

should

 

be

 

shut

 

down

 

and

 

allowed

 

to

 

cool

 

off

 

when

 

the

 

over

temperature

 

flag

 

is

 

set

 

low

 

to

 

avoid

 

damage

 

to

 

the

 

module.

 

 
 
 
 
 

 
 

 

Summary of Contents for NUPOWER L60T01

Page 1: ...MANUAL NUPOWERTM L60T01 L BAND POWER AMPLIFIER PART NUMBER NW PA L60T01 NuWaves Engineering 132 Edison Drive Middletown Ohio 45044 PH 513 360 0800 FAX 513 539 8782 www nuwaves com product sales nuwave...

Page 2: ...letely Characterized The NuPower family of solid state power amplifiers has been completely characterized over temperature voltage and frequency These high performance modules offer significant value...

Page 3: ...l for size weight and power constrained RF telemetry and tactical communication systems The NuPowerTM L60T01 ruggedized chassis allows the system integrator to easily incorporate the unit into a platf...

Page 4: ...t Power 1 dB Compression 41 dBm 960 MHz 43 dBm 1175 MHz 43 dBm 1390 MHz RF Gain 48 dB typ Input VSWR 1 9 typ 2 3 max Output Mismatch No Damage 10 1 Nominal Input Drive Level 0 dBm Maximum Input Drive...

Page 5: ...Temperature 40 to 60 o C ambient 40 to 85 o C baseplate Storage Temperature 55 to 85 o C Table 3 NuPower L60T01 Mean Time Between Failure MTBF Conditions Hours Ground Benign GB 292 657 Airborne Inhab...

Page 6: ...NICAL SPECIFICATIONS Figure 2 NuPower L60T01 Mechanical Outline Table 4 NuPower L60T01 Mechanical Specifications Parameter Specification RF Connectors SMA female Control Power Interface Connector 9 Pi...

Page 7: ...banana plugs Figure 3 The NuPower PA Kit offers out of the box operation for the user The 28 VDC fan cooled heatsink is shown with the NuPower L60T01 mounted Caution The use of external heat sinking i...

Page 8: ...nsmission line or coaxial cable Avoid using damaged cables or corroded connectors while attaching the unit to an antenna Terminating the antenna terminal into a 50 power attenuator with minimum 20 dB...

Page 9: ...ed into 50 otherwise the PA could be damaged 4 1 INTERFACE CABLE HARNESS The cable harness that connects the host controller to the 9 pin Micro D connector of the NuPower L60T01 is made up of 9 wires...

Page 10: ...in transmit mode The user can either connect the RF Enable line to pins 1 2 6 8 on the CTRL PWR interface connector or an open drain logic line capable of sinking 500 A to place the unit in transmit m...

Page 11: ...sing of a NuWaves product Do not remove the cover or any hardware Do not remove components from the circuit card assembly Do not incinerate Do not crush or shred Do not dispose of as unsorted municipa...

Page 12: ...Sales Phone 513 360 0800 Email support nuwaves com NuWaves Home Page https www nuwaves com Product Warranty https products nuwaves com wp content uploads NuWaves_Warranty_Repair pdf 6 1 GENERAL INFOR...